The EBSD method allows us to confirm the distribution of crystal sizes and the orientation of crystal orientations. In this case, it was found that there is a significant orientation difference in the valleys of the screw, suggesting that there is a high level of residual stress. Additionally, it was observed that small crystal grains are distributed on the surface of the screw. [Summary] ■ Analysis Method - Observation of crystal structure using EBSD ■ Results - It was found that there is a significant orientation difference in the valleys of the screw. - It is inferred that there is a high level of residual stress. - It was also observed that small crystal grains are distributed on the surface of the screw. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce an example of analysis of chip surface wiring (Al) using EBSD. The package resin was opened using a chemical solution/RIE, and an analysis of the Al pattern on the chip surface was conducted using EBSD. As a result, orientation was observed in the Al wiring. The normal orientation is distributed, suggesting the presence of many crystals. 【Overview】 ■ Analysis Method - The package resin was opened using a chemical solution/RIE. - An analysis of the Al pattern on the chip surface was conducted using EBSD. ■ Results - Orientation was observed in the Al wiring. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDuring reliability testing, the samples change moment by moment. Do you have any questions such as "At what point did the crack occur?", "How does the degradation progress?", or "How much has it changed from the initial state?" By combining it with reliability testing, we will evaluate the subject in a time-series and non-destructive manner. 【Features】 ■ Applicable for observing changes in whiskers, migration, pressure resistance, solder evaluation, chemical corrosion tests, and aging products in the market ■ Environmental tests and observation frequency will be conducted according to customer requirements ■ Additional analyses such as electrical characteristics, SEM observation, elemental analysis, and cross-sectional observation are also available *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Aites Co., Ltd., we conduct depth-direction analysis of thin film layers using angle-resolved XPS. By changing the angle between the sample and the XPS photoelectron detector, it is possible to alter the detection depth of the photoelectrons. The data obtained from this is numerically analyzed through simulation and converted into a depth profile. We achieve depth-direction analysis of uniform thin films in the nanometer order near the surface, which is difficult to measure using conventional ion etching methods. We also have examples of analyzing the depth direction of HDD magnetic surfaces. 【Features】 ■ Non-destructive depth-direction analysis of thin films in the nanometer order is possible ■ Achieves depth-direction analysis of uniform thin films *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMany defects occur during the manufacturing process of products and during their use. Among these, there are challenges related to material properties, and for those who are wondering, "It’s probably due to the material, but what should I do about it?", we propose suitable solutions from the perspectives of electronics, atoms, molecules, and chemical reaction mechanisms. ■Examples of Issues - What is causing this discoloration? - Why did it crack so quickly? - What is the reason it tears immediately during a tensile test? *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the pre-treatment for cross-sectional observation (sample cutting and resin embedding) conducted by Aites Co., Ltd. We use cutting equipment suitable for cutting large substrates and thick components, such as the band saw "HOZAN K-100" and the IsoMet "Buehler Low Speed Saw" for sample cutting. With the "HOZAN K-100," samples up to approximately X150mm, Y230mm, and Z70mm in size can be cut. Additionally, after cutting, the samples are embedded in epoxy resin or similar materials, but it is also possible to embed in resin before cutting. 【Product Lineup】 ■ Band Saw ■ IsoMet ■ Multifunctional Diamond Wire Saw *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the cutting process using wire saws at Aites Co., Ltd. With a wire saw, it is possible to create multiple cross-sections from a single sample without cutting through, allowing for further observation and analysis. Additionally, in cutting examples, even small and brittle white rice can be divided without cracking or chipping. If you have any requests regarding cutting processes or observation and analysis, please feel free to contact us. *For more details, please refer to the PDF materials or feel free to reach out to us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAites Co., Ltd. conducts slicing processing using isomet. When you want to observe the cross-section of all connector pins in multiple rows, the usual procedure is to grind down to the next row... However, by performing slicing processing, it is possible to keep the created cross-section as it is. Additionally, we have examples of slicing processing for connector pins with multiple rows. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur "Micro Raman Spectrophotometer" employs a confocal optical system, allowing for the adjustment of the focal position in the depth direction, similar to a microscope, enabling material analysis of each layer from the surface of multilayer films. Using the confocal function of the micro Raman spectrophotometer, the focus of the Raman laser light can be varied in the depth direction. Additionally, by continuously changing the focal position, it is possible to acquire spectra continuously in the depth direction. 【Features】 ■ Adoption of a confocal optical system ■ Enables material analysis of each layer from the surface of multilayer films ■ Capable of varying the focus of the Raman laser light in the depth direction ■ Allows for continuous acquisition of spectra in the depth direction *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company offers a service to replace CRT monitors, such as those used in machine tools, with LCD displays. Do you have concerns like "the CRT monitor won't turn on" or "I only want to repair the monitor"? If the monitor can be replaced and the machine tool can be used again, it can lead to cost savings compared to purchasing new equipment. Please feel free to contact us regarding the possibility of repairs. 【Process for Replacement】 1. Check the CRT signal line 2. Connect the signal from the CRT to the signal converter 3. Connect the output of the signal converter to the LCD 4. Adjust the settings of the signal converter and check the screen *You can view the flyer for this service by clicking the download button.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces a comparison of components in PC monitors and digital clocks using gas chromatography-mass spectrometry (GC-MS). Liquid crystal displays contain small organic substances (liquid crystal molecules). These have evolved into molecular structures suitable for product characteristics due to technological innovations. Our company clarifies these differences at the molecular level using GC-MS, allowing us to confirm that the liquid crystal molecules are appropriate for their intended use and to check for the presence of impurities. [Contents] ■ Comparison of components in PC monitors and digital clocks using GC-MS ■ Case studies of GC-MS analysis of liquid crystal components We compared the number of components and characteristics of segment-type liquid crystal displays (digital clocks) and color TFT liquid crystal displays (PC monitors). *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Aites Co., Ltd., we offer analysis and reliability evaluation services for "crystallinity analysis of resin materials using micro-Raman spectroscopy." By analyzing the spectra obtained from a micro-Raman spectrophotometer, it is possible to determine the crystallinity of resin materials in fine detail based on the differences in the half-width of the peaks. We also have case studies analyzing the changes in crystallinity from the mouth of PET bottles to the bottle body. Please leave the analysis, evaluation, and reliability assessment to us. 【Overview】 ■ Crystallinity analysis of resin materials using Raman spectroscopy - The linewidth of the Raman spectrum changes to reflect crystallinity - It is possible to determine the half-width of the C=O stretching band and crystallinity - Relative crystallinity of PET can be determined *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company scans the sample surface with a micro probe to achieve nano-level structural analysis. In "shape measurement (tapping mode)," the probe, which is periodically vibrated, lightly taps the sample surface to measure its shape. Additionally, "phase imaging" maps the phase delay between the periodic signal that moves the cantilever and the cantilever's vibration, visualizing differences in physical properties that do not appear in the shape. 【Features】 ■ High-resolution imaging with a micro probe ■ Measurement possible for conductors, semiconductors, and insulators ■ Measurement can be conducted almost non-destructively with minimal contact pressure *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case where water droplet-shaped contaminants were created on a Si wafer through reproducibility experiments. Measurements were conducted at the same location using SEM-EDX and TOF-SIMS, and a comparison of the image maps was made. In the TOF-SIMS image map, organic substances (CH, CN), Na, and K were detected around the watermark. While no contaminants were observed around the watermark in the optical image, SEM image, and EDX analysis, the TOF-SIMS image map revealed that trace amounts of contaminants were present. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTOF-SIMS can detect elements and organic molecules, as well as fragment ions, making it effective for organic analysis. As an example of organic analysis, we will introduce a case study of polyethylene glycol. Secondary ion mass spectra can provide valuable insights for the qualitative analysis of organic substances. In this case study, we can confirm the characteristic repeating structure of polyethylene glycol (C2H4O) as a group of peaks with a mass difference of 44. Calculating from the mass number, the terminal ends are likely H- and HO-, suggesting they are detected as protonated species. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTMA (Thermomechanical Analysis) is a method that measures the dimensional changes of a sample while applying a constant load and varying the sample temperature. It provides information on thermal expansion, thermal contraction, glass transition temperature, and more. The temperature range is from -150 to 1000°C, with a maximum size of Φ10×25mm (compression mode, needle insertion mode) and a maximum size of 0.7mm×5mm×20mm (tensile mode) being the measurable conditions. This document includes case studies of TMA analysis for semiconductor encapsulants. 【Features】 ■ Thermomechanical analysis ■ Applying a constant load to the sample while varying the sample temperature ■ Measuring the dimensional changes of the sample ■ Obtaining information on thermal expansion, thermal contraction, glass transition temperature, etc. ■ Multiple measurement modes *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTG-DTA (Thermogravimetric Differential Thermal Analysis) is an analysis that simultaneously measures the weight of a sample (TG) and the temperature difference between the sample and a reference material (Differential Thermal Analysis) (DTA) as a function of temperature, while changing the sample's temperature according to a specific program. The measurable conditions are a temperature range of room temperature to 1000°C, a required sample amount of 10 to 20 mg, and sample shapes including film, powder, and bulk. 【Features】 - Thermogravimetric Differential Thermal Analysis - Changes the sample's temperature according to a specific program - Simultaneously measures the sample's weight and the temperature difference from the reference material as a function of temperature - Required sample amount: 10 to 20 mg - Sample shapes include film, powder, and bulk *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDSC (Differential Scanning Calorimetry) is an analytical method that determines the heat difference based on the temperature difference between the sample and a reference material caused by temperature changes in the sample, allowing for the observation of the degree of endothermic/exothermic reactions of the sample. The temperature range is -90°C to 550°C, the required sample amount is 5 to 10 mg, and the sample shapes that can be measured include film, powder, and bulk. 【Features】 ■ Differential Scanning Calorimetry ■ Observation of the degree of endothermic/exothermic reactions of the sample ■ Temperature range: -90°C to 550°C ■ Required sample amount: 5 to 10 mg ■ Sample shapes: film, powder, bulk *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"DMA (Dynamic Mechanical Analysis)" is an analysis that applies periodic oscillating loads to polymer materials and measures elasticity and viscosity as a function of temperature from the resulting stress and phase difference. It provides information related to the molecular motion and molecular structure of polymers, such as glass transition and relaxation. 【Features】 ■ Dynamic mechanical analysis ■ Applies periodic oscillating loads to polymer materials ■ Measures elasticity and viscosity as a function of temperature ■ Obtains information related to the molecular motion and molecular structure of polymers ■ Numerous measurement modes *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn this document, we introduce various analysis cases conducted by our company using X-ray fluoroscopy and CT inspection equipment. It includes examples such as "BGA solder crack analysis case" from X-ray fluoroscopy and angled CT observation, as well as observations of "surface mount LEDs" and "chip resistors." 【Contents (excerpt)】 ■ BGA solder crack analysis case (X-ray fluoroscopy observation) ■ Surface mount LEDs ■ Chip resistor observation case ■ Reflow simulator ■ Microphone observation case (X-ray fluoroscopy observation & orthogonal CT observation)... ★ Currently, we are offering a free collection of case studies on X-ray fluoroscopy and CT inspection equipment! You can view it immediately via "PDF download." * For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces an example of an analytical method for molecular structure analysis. It includes structural analysis using IR and Raman for liquid crystal polymers (LCP), TIC data from GC-MS analysis of low molecular weight liquid crystals (for LCD), as well as detected substances, presented with figures and tables. For analysis at the quantum level, please consult the technical group "Aites," known for their extensive expertise. 【Contents (excerpt)】 ■ Liquid Crystal Polymers (LCP) ■ Structural analysis of LCP (fully aromatic polyamide) ■ Structural analysis using IR ■ Structural analysis using Raman ■ Structural analysis using XPS (ESCA) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationX-ray observation is a method of non-destructive testing and is the first inspection performed for analysis and evaluation. It is effective for initial observation of various components and materials, including implemented substrates and electronic parts. Additionally, CT inspection can capture structures in three dimensions, allowing for visual judgment. The "Cheetah EVO" is equipped with a reflow simulator, enabling real-time observation of phenomena such as void behavior during soldering, which can be utilized for setting reflow conditions and selecting solder. 【Device Specifications】 ■YXLON Cheetah EVO - X-ray generator: Multi-focus transmission type - Tube voltage: 25-160kV - Tube current: 0.01-1.0mA - Tube power: 64W - Additional features: Orthogonal CT, oblique CT, reflow simulator *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case study of the combined use of X-ray transmission observation and CT scanning equipment with image processing technology. In the transmitted X-ray images of normal substrates and defective substrates, the wiring was intricately laid out, making it difficult to identify abnormalities at first glance. However, image processing allowed us to detect the differences between the images of normal and defective products. Identifying defective areas from a wide field of view is challenging, especially in cases of pattern abnormalities in substrate wiring. However, by using image processing software in conjunction, it becomes possible to discover abnormal areas. [Case Study of Combined Use of Transmission Observation and Image Processing Technology] ■ Detection of differences between images of normal and defective products through image processing - Upon checking the white spots in the X-ray transmission image of the defective product, a shape resembling a broken wire was confirmed. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case of observing wisdom teeth (third molars) using X-ray CT. Over 10 years ago, the wisdom tooth extracted by the photographer was observed using X-ray CT. Compared to X-ray fluoroscopy images, the enamel on the surface of the tooth and the underlying dentin were clearly observed. [Observation Case of Wisdom Teeth] ■ Compared to X-ray fluoroscopy images, the enamel on the surface of the tooth and the underlying dentin were clearly observable. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the features of the YXLON "Cheetah EVO" that we have implemented. The "Reflow Simulator" allows for real-time observation of phenomena such as void behavior during soldering. It can be utilized for determining reflow conditions and selecting solder. 【Features】 ■ Ceramic heater & lamp heating ■ Target size: 40x40x20mm ■ Maximum set temperature: 350 degrees ■ Real-time observation capability ■ Usable for determining reflow conditions and selecting solder *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case of observing microphone components using X-ray fluoroscopy and orthogonal X-ray CT. MEMS chips and Si chips are transparent, making them only faintly observable. However, in the X-ray fluoroscopic images, the wire bonding and the wiring patterns of the mounted substrate can be observed. In the orthogonal CT images, MEMS chips and Si chips can be observed more clearly compared to the fluoroscopic images. Additionally, while the fluoroscopic images show the observation of overlapping layers, the CT images allow for observation of each layer individually. [Observation Case of Microphone] ■ X-ray Fluoroscopic Image - Wire bonding and wiring patterns of the mounted substrate can be observed. ■ Orthogonal CT Image - MEMS chips and Si chips can be observed more clearly compared to the fluoroscopic images. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case study of observing chip resistors using X-ray imaging and CT scanning. Chip resistors have a structure where a thin film of metal (resistive element) is formed on the surface of ceramics. The L-shaped lines visible in the X-ray image are trimming marks applied to adjust the resistance value. CT observation allows for viewing the desired cross-sectional images and enables three-dimensional observation, making it effective for analysis. If any defects are found during X-ray or CT observation, cross-sectional observation and elemental analysis will be conducted to investigate the cause. [Case Study of Chip Resistor Observation] ■ CT Observation - It is possible to view the desired cross-sectional images. - Effective for analysis due to the ability to observe in three dimensions. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where the moment a surface-mounted LED is damaged due to overload was captured through X-ray observation. In this case, the surface-mounted LED was powered on, and the voltage and current were gradually increased from the rated values until it became non-functional due to overload. This process was recorded. Additionally, you can view the process of it becoming non-functional in a video. 【LED Failure Observation Case】 ■ After becoming non-functional - Melting, disconnection - Change in the loop shape of the wire - Delamination of the phosphor - Changes in the shape and size of voids *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case study of BGA solder crack analysis using X-ray imaging and CT scanning. When observing the BGA connection area of a circuit board that had become electrically open using X-ray imaging, cracks were confirmed to have occurred at the BGA connection. Additionally, we examined the cracks in the solder connection observed through X-ray imaging using oblique CT. Oblique CT provides clear planar information, but spherical shapes like solder balls and voids appear elongated in the vertical direction due to specific factors of oblique CT. While it is difficult to obtain cross-sectional information about the cracks occurring at the solder joint interface, there is the advantage of being able to observe the circuit board non-destructively. [Analysis Cases] ■ X-ray imaging observation ■ Oblique CT observation ■ Orthogonal CT observation ■ Cross-sectional observation *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case of observing an inductor coil (orthogonal CT observation + cross-sectional observation). The inside of an inductor coil that experienced operational failure was observed using X-ray CT. It was confirmed that abnormal shapes occurred in various places of the spirally formed wiring. With X-ray CT observation, it is possible to observe in three dimensions, making the condition of the abnormal areas clear. Additionally, cross-sections including the abnormal areas were created through mechanical polishing, and observations were conducted using SEM. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationHere are some examples of observations of IC-type coils. Through X-ray observation, we can clearly capture the internal structure by using methods suited to the purpose. In transmission observation, we can quickly detect metal foreign objects, and in CT observation, we can obtain three-dimensional images of any cross-section, making it suitable for observations where positional information and shape are important. Unlike transmission observation, we can also assess the winding condition of the coil wiring. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the products handled by Aites Co., Ltd.: "Evaluation Pattern Wafers," "Silicon Wafer Sales," and "Compound Semiconductors." The "Evaluation Pattern Wafers" are created as test pattern wafers with various structures for evaluation of CMP, deposition equipment, cleaning equipment, and various materials. We accept even a few prototype evaluations without any issues and are well-known for our very flexible responses, from mask design to cross-sectional dimension measurements. 【Features】 <Evaluation Pattern Wafers> ■ Creation of test pattern wafers with various structures for evaluation of CMP, deposition equipment, cleaning equipment, and various materials. ■ Accepting even a few prototype evaluations without any issues. <Silicon Wafer Sales> ■ A wide range of products from particle-free items for semiconductor front-end processes to inexpensive coin roll wafers for back-end processes. ■ Capable of film deposition processing on silicon wafers, BG thinning processing, dicing processing, as well as complex notch processing and through-hole processing. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Aites, we provide total solution services for power devices, including reliability testing, analysis, and evaluation. We offer services such as the "Power Cycle Tester," which can simultaneously conduct transient thermal measurements, as well as "Failure Analysis of Compound Semiconductors," "Concentration Analysis of Diffusion Layers," and "Cross-Section Analysis of Modules." We will make proposals based on specific achievements. Keywords: ■General Power Semiconductors (chips, module TIM materials, etc.) ■Reliability Testing/Evaluation ■Structural Analysis (Quality, Competitor RE) ■Failure Analysis (Identification of Failure Locations, Cause Investigation, Improvement Proposals) 【List of Tests】 ■Power Cycle Testing ■Liquid Tank Thermal Shock Testing ■Gate Bias Testing ■Non-destructive Observation of Semiconductor/Package Delamination ■Failure Analysis of Power Chips, etc. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt AITES Co., Ltd., we offer "Module Prototyping and Thermal Resistance Evaluation." In the evaluation of power devices and the materials used in power devices, measuring thermal resistance by actually assembling the device is an effective method for understanding its performance. We can handle everything from prototyping to evaluation. If you are interested, please feel free to consult with us. 【Features】 <Prototyping of Power Modules> ■ We provide a consistent, flexible, and cost-effective service from chip procurement to module assembly. ■ Suitable for evaluating die attach and TIM materials. <Transient Thermal Resistance Measurement> ■ We conduct transient thermal resistance measurements using the T3Ster (power cycle testing device built-in) for power devices, obtaining structural functions and performing thermal analysis. ■ Using this data, we can compare materials, calculate thermal resistance, and estimate defective areas. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Aites Co., Ltd., we offer contract power cycle testing using Siemens (Mentor) power cycle testing equipment. We can also handle the creation of various jigs necessary for testing. Additionally, we accommodate various observations and measurements of power devices. We can capture changes before and after tests such as power cycle testing. 【Features】 ■ We can handle the creation of various jigs necessary for testing. ■ We accommodate various observations and measurements of power devices. ■ We can capture changes before and after tests such as power cycle testing. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt AITES Co., Ltd., we offer "environmental testing in a high-power constant temperature and humidity chamber." It is capable of a constant temperature change of up to 15°C/min (-45 to ±155°C). Temperature cycle testing can be conducted by controlling the temperature gradient. Additionally, the temperature control range is wider than that of typical constant temperature and humidity chambers, with control possible at 95°C. 【Features】 ■ Two high-power constant temperature and humidity chambers introduced ■ Constant temperature change of up to 15°C/min (-45 to ±155°C) is possible ■ Temperature cycle testing can be conducted by controlling the temperature gradient ■ Temperature control range is wider than that of typical constant temperature and humidity chambers ■ Control possible at 95°C *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document presents the bonding interface of Cu wire bonding in semiconductor packages. It provides a detailed explanation of samples and methods, various wire bonding techniques, results, and discussions, accompanied by figures and photographs. [Contents] ■ Introduction ■ Samples and Methods ■ Various Wire Bonding Techniques ■ Results and Discussion ■ Conclusion ■ References *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document explains the bonding interface of Cu wire bonding in semiconductor packages. It details the purpose and wire bonding, the characteristics of Cu wire bonding, the Cu-Al compounds at the bonding center, micro voids, and the growth (diffusion) of Cu-Al compounds, accompanied by diagrams and photographs. [Contents (excerpt)] ■ Purpose and wire bonding ■ Samples and methods ■ Procedures and flow ■ Characteristics of Cu wire bonding ■ Selection of cross-sectional preparation methods *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Aites Co., Ltd., we conduct analysis of semiconductor diffusion layers using sMIM. The Scanning Microwave Impedance Microscopy (sMIM) is characterized by signals that have a linear correlation with dopant concentration. sMIM scans the sample by irradiating microwaves from the tip of a metal probe attached to an SPM and measures the reflected waves to obtain sMIM-C images that have a linear correlation with the concentration of the diffusion layer. The C component of Zs obtained from the reflectivity consists of the oxide film capacitance and the depletion layer capacitance. By utilizing the fact that the depletion layer width changes depending on impurity concentration, we detect changes in concentration as changes in C. [Application Examples] ■ sMIM-C: Visualization of diffusion layers and semi-quantitative evaluation of dopant concentration for various semiconductor devices such as Si, SiC, GaN, InP, and GaAs. ■ dC/dV: Evaluation of diffusion layer shape, determination of p/n polarity, visualization of the depletion layer. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the products handled by Aites Co., Ltd.: "Evaluation Pattern Wafers," "Silicon Wafer Sales," and "Compound Semiconductors." The "Evaluation Pattern Wafers" are created as test pattern wafers with various structures for evaluating CMP, deposition equipment, cleaning equipment, and various materials. We accept even a few prototype evaluations without any issues and are well-known for our very flexible responses, from mask design to cross-sectional dimension measurement. 【Features】 <Evaluation Pattern Wafers> - Various structures of test pattern wafers are created for evaluating CMP, deposition equipment, cleaning equipment, and various materials. - We accept even a few prototype evaluations without any issues. <Silicon Wafer Sales> - We handle a wide range of products from particle-free items for semiconductor front-end processes to inexpensive coin roll wafers for back-end processes. - We can also perform film deposition processing, BG thinning processing, dicing processing, as well as complex recess processing and through-hole processing on silicon wafers. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the defects of solar cell modules and presents cases where various cross-sectional analyses were conducted for observation and analysis, along with the factors contributing to degradation. It includes an introduction to the "basic structure of solar cells" as well as "non-destructive analysis and destructive analysis," using diagrams and photographs. We encourage you to read it. 【Contents】 ■ Introduction ■ Basic Structure of Solar Cells ■ Non-Destructive Analysis and Destructive Analysis ■ Various Defect Modes ■ Conclusion *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company supports customers in solving their challenges and problems not only with electronic components but also with a wide range of products, parts, and materials, including inorganic and organic materials, through failure analysis, defect analysis, structural analysis, and reliability evaluation. This document introduces how to approach analysis and evaluation techniques from various perspectives. We hope it serves as a starting point and a helpful resource for our customers in resolving issues. [Contents] ■ Introduction ■ Image of Joining and Positioning of Our Evaluation and Analysis Techniques ■ Causes of Defects ■ Methods ■ Conclusion *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOne of the reliability evaluation methods, the ion migration evaluation test, has become increasingly important as a pre-evaluation due to the transition of products towards being lighter, shorter, and smaller. This document provides an overview of ion migration evaluation and the details of the test implementation using an example of our evaluation tests. We will also introduce the usefulness of the continuously measuring (In-Situ) equipment used in the evaluation tests. [Contents] ■ Introduction ■ Ion Migration ■ Ion Migration Evaluation Test ■ Evaluation Method ■ Evaluation Test Case ■ Conclusion ■ References *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe have introduced the "GC-MS Gas Chromatograph Mass Spectrometer" manufactured by Shimadzu Corporation. This is one of the analytical methods aimed at qualitative and quantitative analysis of components contained in samples, used for the qualitative and quantitative analysis of volatile organic compounds such as parts, materials, residual solvents, and additives. It is necessary for the measurement target to be gasified (with a boiling point below 300°C), but it is suitable for component analysis of mixtures due to its higher sensitivity compared to IR and RAMAN, as well as the ability to separate components in the GC section. 【Overview of GC-MS Equipment】 ■ GC-MS Main Unit: GC-2030, GCMS-QP2020 NX ■ Headspace Sampler: HS-20 ■ Pyrolysis Analyzer: Multi-Shot Pyrolyzer Py-3030 ■ Specifications ・Detection Limit: Several ppm (varies depending on the measurement target) ・Headspace: 40–300°C, sample size 13mm x 40mm or smaller ・Pyrolysis Analyzer: 50–1050°C (EGA measurement compatible), sample size up to 4mm *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Cheetah EVO" is an X-ray imaging and CT inspection device equipped with a reflow simulator, allowing real-time observation of phenomena such as void behavior during soldering. It can be utilized for setting reflow conditions and selecting solder. Our company has examples of using this product for "observation of inductor coils," as well as "BGA solder crack analysis" and "observation of IC-type coils." 【Device Specifications (Excerpt)】 ■ X-ray Generator: Multi-focus transmission type ■ Tube Voltage: 25–160 kV ■ Tube Current: 0.01–1.0 mA ■ Tube Power: 64 W *For more details, please refer to the PDF document or feel free to contact us.