analyzer Product List and Ranking from 52 Manufacturers, Suppliers and Companies | IPROS

Last Updated: Aggregation Period:Feb 18, 2026~Mar 17, 2026
This ranking is based on the number of page views on our site.

analyzer Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Feb 18, 2026~Mar 17, 2026
This ranking is based on the number of page views on our site.

  1. 共栄システム産業 Osaka//Trading company/Wholesale
  2. マイクロニクス Tokyo//others
  3. 新栄電子計測器 Kanagawa//Electrical equipment construction business
  4. 4 ファラッド Tokyo//Trading company/Wholesale
  5. 4 ラインアイ Kyoto//Information and Communications

analyzer Product ranking

Last Updated: Aggregation Period:Feb 18, 2026~Mar 17, 2026
This ranking is based on the number of page views on our site.

  1. Digital TV Spectrum Analyzer "DS2831 Series" 共栄システム産業
  2. Battery Analyzer "BTA-3000Plus" 新栄電子計測器
  3. Ultra-compact spectrum analyzer (10MHz to 3GHz) ファラッド
  4. Transport Stream Analyzer "TSReader" B7
  5. 5 Goodman Product Catalog for Electrical and Communication GOODMAN

analyzer Product List

1~30 item / All 251 items

Displayed results

Surge Analyzer: Simulated execution of shock voltage application tests and winding tests.

Various simulation tests conducted prior to surge testing of high-voltage electrical equipment and power cables.

This is a system capable of testing large capacity loads such as power cables. It can also perform impulse voltage application tests, twisting tests, and tests for large capacity loads. The system configuration has been completely renewed while maintaining the functionality of measuring instruments from about 30 years ago. 【Features】 - Capable of outputting surge waveforms with a maximum of 100Vpp and pulse widths from 5us to 400us - New functions "Software-controlled time constant adjustment" "Touch panel adoption" "Time constant setting storage"

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Multi-Protocol Analyzer 'LE-8500X-SE'

Supports measurement and testing of single-pair Ethernet.

The "LE-8500X-SE" is a multi-protocol analyzer capable of measuring and evaluating three standards: 100BASE-T1, 10BASE-T1L, and 10BASE-T1S. It also features measurement capabilities for SPoE/PoDL, and the measured communication data and SPoE/PoDL power data can be automatically saved as log data to an external storage device connected via USB 3.0, with timestamps corrected for time using GNSS (PPS). The recorded data can be checked on the analyzer's display in real-time, making it useful for the development and evaluation of single-pair Ethernet devices in various scenarios. Additionally, a version with Wi-Fi connectivity, the "LE-8500XR-SE," is also available. 【Features】 - Supports measurements for 100BASE-T1, 10BASE-T1L, and 10BASE-T1S - Real-time monitoring and recording of packets - SPoE/PoDL measurement capabilities and PSE diagnostics (pseudo PD) function *For more details, please refer to the related links or feel free to contact us.

  • Other measuring instruments
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

MDA-510/MDA-550 Motor Drive Analyzer

Motor Drive Analyzer that simplifies analysis through the adoption of guided measurements.

The "MDA-510" and "MDA-550 Motor Drive Analyzer" save measurement time, eliminate the hassle of complex measurement setups, and simplify the troubleshooting process for variable frequency drives. By simply selecting a test, the voltage and current connection points are indicated through a step-by-step measurement guide, allowing you to obtain all the necessary data from important motor drives according to a pre-set measurement profile, from input to output, DC bus, and the motor itself. 【Features】 ■ Guided test setup and automatic drive measurement ■ Simplifies troubleshooting of complex motor drives ■ Achieves reliable and reproducible test results *For more details, please refer to the external link or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

FTIR Analyzer "MultiGas TM Purity"

High-sensitivity analyzer for bulk process gas analysis based on FTIR!

"MultiGas TM Purity" is an FTIR-based analyzer capable of detecting ppb-level impurities in high-purity bulk process gases. It excels in identifying impurities in bulk gases with high-resolution analysis. 【Features】 ■ Proven contribution to quality improvement in bulk gas manufacturing with gases such as NF3, NH3, and H2. ■ Configuration that accommodates corrosive high-purity gases: - Sample line and gas cell are of welded 316SS type. - Utilizes a heated optical path to reduce contaminants from moisture and the atmosphere. *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analyzer "AIRGARD CWA/TIC"

Atmospheric environment analyzer for continuous monitoring of chemical weapons and toxic industrial chemicals.

The "AIRGARD CWA/TIC" is an ultra-high sensitivity gas analyzer that rapidly detects toxic gases using Fourier Transform Infrared Spectroscopy. It is capable of detecting most CWAs and TICs at ppb levels below toxic IDLH levels within 20 seconds. With its low-level detection capability and fast response, it ensures sufficient time for appropriate actions in the event of a shutdown of the air conditioning system, indoor evacuation, or evacuation from a disaster area. Thorough testing has been conducted by the U.S. Department of Defense to prevent unnecessary outdoor evacuations, associated business shutdowns, and emergency notifications. 【Features】 ■ Detection limit in the low ppb range - identifies and alerts a wide range of harmful substances ■ Standard time to issue alerts and identify harmful chemicals is less than 20 seconds ■ Self-contained unit with built-in computer and sampling pump ■ Continuous atmospheric monitoring capability (7 days a week / 24 hours a day) ■ Remote troubleshooting capability *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

B-H Analyzer SY-8219

Core loss/B-H curve measurement. Wideband measurement frequency of 1 MHz. Ideal for research and development of power transformers, choke coils, motors, and more.

The "B-H Analyzer SY-8219" is a device for measuring the AC magnetic properties of soft magnetic materials. It is ideal for the research and development, quality assurance, and manufacturing departments of material, core, component, and device manufacturers for new product development and product inspection. In addition to BH/Pc measurement capabilities, it can also measure m/L/Q. The measurement frequency ranges from 10Hz to 1MHz for both sine waves and pulse waves. For more details, please download the catalog or contact us.

  • Other measuring instruments
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

B-H Analyzer SY-8218

For core loss/B-H curve measurement! The top model of Iwattsu's B-H analyzer. Ultra-wideband measurement frequency of 10 MHz.

The "B-H Analyzer SY-8218" is a device for measuring the AC magnetic properties of soft magnetic materials. It is ideal for the research and development, quality assurance, and manufacturing departments of material, core, component, and device manufacturers for new product development and product inspection. In addition to BH/Pc measurement capabilities, it can also measure m/L/Q. The measurement frequency ranges from 10Hz to 10MHz for sine waves and 10Hz to 1MHz for pulse waves. For more details, please download the catalog or contact us.

  • Other measuring instruments
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[New Release] Thermal Interface Material Analyzer

It is possible to measure the thermal conductivity, thermal resistance, and interfacial thermal resistance of TIMs in thin films of less than 50μm in conditions close to actual products.

The measurement samples (gel-like liquids, sheets, solids) are measured between two metal test heads with known thermal conductivity (aluminum or copper) in the shape of a cylinder or rectangular prism. The temperature gradient ΔT and heat flow Q in the sample are measured, and the effective thermal resistance Rtheff is determined. By changing the thickness of the sample while applying pressure and repeating the measurements, the thermal conductivity (W/m·K), thermal resistivity (mm²·K/W), and interfacial thermal resistivity (mm²·K/W) of the sample can be calculated using the formulas and graphs below. TIMA5 is a groundbreaking device that can control the sample thickness (gap), pressure, or sample temperature for measurements. Download the catalog here▼ https://www.matsuo-sangyo.co.jp/catalogs/ For product details, click here▼ https://www.matsuo-sangyo.co.jp/products/thermal-interface-material-analyzer/

  • Other analytical equipment
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: Antenna Matching Method

Examples of reference correction and matching methods for network analyzers are published along with diagrams!

Matching controls the combination of series and parallel based on the initial impedance position on the Smith chart, aligning it to the center point (50Ω). The values of L and C will vary depending on the frequency and initial impedance, so please adjust by trying several values. This document introduces "Reference Calibration of the Network Analyzer" and "Examples of Matching Methods." We encourage you to read it. 【Contents】 ■ Reference Calibration of the Network Analyzer ■ Points to Note ■ Examples of Matching Methods *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Parts and Materials
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Digest (Comprehensive Catalog of Wireless Evaluation Equipment)

Micronics Corporation provides measurement instruments and high-frequency related equipment to the world.

This is an announcement of the "Wireless Evaluation Equipment Comprehensive Catalog" from Micronics Corporation. Micronics provides measurement instruments and high-frequency related equipment to the world. Here is the announcement of Micronics' "Wireless Evaluation Equipment Comprehensive Catalog." ■□■Contents■□■ ■Spectrum Analyzers / Signal Analyzers ■EMC Test Systems ■Anechoic Chambers / Shielded Boxes ■ETC / DSRC Test Systems ■Variable Attenuators ■Signal Generators ■Test Accessories You can view the catalog by clicking the download button. For more details, please contact us through the document request.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Example: Conducted EMI Measurement System

A system that enables easy and inexpensive conducted EMI measurements using an EMI spectrum analyzer.

This is a notice from Micronics Corporation regarding the "Conducted EMI Measurement System (Application Document)." A system that enables easy and cost-effective conducted EMI measurements using an EMI spectrum analyzer. ■□■ Solution ■□■ ■ EMI Spectrum Analyzer / MSA438E - Equipped with the necessary functions for conducting EMI tests (QP, average detection, and RBW: 9kHz, 120kHz [6dB]), making it ideal for EMI measurements. - As a preliminary test for EMI testing, it can reduce the amount of countermeasures required and the number of times the measurement site is used, significantly lowering running costs. ■ Dedicated EMI Measurement Software / MAS430 - When used, it allows you to specify the standards you want to measure, such as CISPR11, 22, EN55011, 22, FCC Part 15, VCCI, etc., and automatically sets the necessary parameters like bandwidth and threshold level. For other functions and details, please download the catalog or contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] Simplified Measurement in Technical Standard Compliance Testing, etc.

Characteristic testing of wireless communication devices

It is possible to easily implement transmission characteristic tests for obtaining certifications and approvals in various countries, such as the Technical Standards Conformity Test (TELEC). 【Features】 ○ By connecting the signal output from the EUT's antenna (RF) terminal to a spectrum analyzer or power meter, it is possible to evaluate each item of the transmission characteristic test. ○ By using a shielded box, it is possible to prevent the influence of external radio waves and electromagnetic waves on the EUT. ○ Frequency deviation ○ Occupied frequency bandwidth ○ Intensity of spurious emissions ○ Deviation of antenna power ○ Adjacent channel or out-of-band leakage power ○ Leakage power when the carrier is off ● For other functions and details, please download the catalog.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] Evaluation of Noise Resistance in Information and Communication Devices

Evaluation of Noise Resistance in Information and Communication Equipment

Verification of the correlation between the type and magnitude of noise and communication speed, as well as resistance 【Features】 ○ Evaluate the impact on the installed EUT (mobile phone module) by oscillating the signal output from the signal generator (SG) within a radio wave anechoic chamber. ○ The frequency range (800MHz to 2.5GHz) is targeted to detect EMC issues in the early design phase and measure the effective throughput of communication using the EUT and control device programs. ○ Verify the correlation between the type and magnitude of noise and communication speed, as well as resistance. ● For other functions and details, please download the catalog.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Radiation Noise Simple Check

[Application Example] Noise checking at a low cost! Simple measurement of transmission frequency.

The system can perform relative evaluations for debugging purposes during pre-assessments before formal testing or in the event of failure. It is a popular simple measurement tool because it allows for low-cost checks of noise components and enables subsequent system upgrades. It can simply measure the frequency bands emitted by the DUT. It is particularly effective for EMC noise countermeasures, radio law compliance, and confirming unwanted radiation. In formal tests using a shielded room, while it may not be possible to identify absolute values, it is possible to check whether unspecified frequencies are being emitted outside the specified limits by combining a spectrum analyzer with a simple loop antenna. 【System Configuration】 ■ EMI Spectrum Analyzer [MSA438E] ■ N to SMA Coaxial Cable 1.5m ■ Small Loop Antenna (set of two sizes) *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Spectrum Analyzer MSA400 Series

Handheld spectrum analyzer with a sweeping method.

Compact, lightweight, and ultra-low price. Performance and functionality that rival large bench-type models. 【Features】 ■ Compact and lightweight at 1.8kg ■ Large color display ■ 4 hours of battery operation ■ Data storage on USB memory ■ High-speed USB transfer ■ Accurate frequency measurement with PLL synthesizer ■ Average noise level -127dBm ■ 100dB display dynamic range ■ Easy operation with AUTO mode

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Simple check of magnetic field radiation noise from LED lighting fixtures.

[Application Example] With easy measurements, you can quickly evaluate the effectiveness of countermeasures, contributing to reduced development time and cost savings.

【Product Introduction】 ■Spectrum Analyzer MSA438 Compact and lightweight. A genuine spectrum analyzer with performance and features that rival those of large bench-type models. The most popular model in the MSA400 series. - Measurement frequency: 50kHz to 3.3GHz ■Loop Antenna MAN120 A small loop antenna with a diameter of 40 cm, suitable for measuring low frequencies.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] Distortion and Adjacent Channel Characteristics of RF Transmission Amplifiers

[Application Example] Signal Analyzer MSA500 Series / Measurement Mode

In high-frequency transmission amplifiers, if the distortion is large, the waveform becomes distorted, resulting in a significant increase in unwanted radio waves leaking into adjacent channels. To observe the effects of improving amplifier characteristics, it is necessary to quantitatively confirm the impact on adjacent channels. Using the MSA500 series, this can be easily verified. 【Product Introduction】 ■ Handheld Spectrum Analyzer MSA500 Series *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] VSWR Bridge Usage Example

[Application Example] Simple Measurement Method for Impedance

The input and output of high-frequency circuits are typically required to be 50Ω. While it is possible to measure using an impedance analyzer or other measurement methods during verification, using the MVS300 allows for easy and simple measurements. 【Product Introduction】 ■ Handheld Spectrum Analyzer MSA338TG ■ Handheld Spectrum Analyzer MSA438TG ■ VSWR Bridge MVS300 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Radio Law and IEEE Simplified Testing for ZigBee Modules

[Application Example] A system that conducts simple tests in accordance with the Radio Law and IEEE using the Signal Real-Time Spectrum Analyzer.

By combining the Signal Real-Time Spectrum Analyzer (MSA500 series) with an anechoic chamber, simple measurements of RF transmission characteristics tests such as technical standards conformity tests (Giteki) and IEEE tests for antenna-integrated equipment can be conducted. By limiting the applications and specifications, it is possible to upgrade the system at a low cost. Physical layer testing for ZigBee involves technical standards conformity certification (Giteki) and IEEE802.15. 【Product Introduction】 ■ Handheld Spectrum Analyzer MSA558 ■ Anechoic Chamber Taurus Series MY1530 ■ I/F Module *For more details, please refer to the PDF materials or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

How to write antenna calibration data to a spectrum analyzer.

[Application Example] You can connect the antenna and spectrum analyzer that the customer has to measure electric field strength.

Typically, to check the frequency and strength of radio waves emitted from wireless communication devices, electric field strength measurements (dBμV/m) are conducted. When using a spectrum analyzer (MSA400 series) in combination with our dipole antennas (M401 to M407), the calibration data (antenna gain) is already reflected, allowing for easy electric field strength measurements based on the settings of the spectrum analyzer. However, if you are using an antenna that you own for electric field strength measurements, you will need to write the calibration data into the spectrum analyzer. By using the PC software (MAS400), you can easily write the calibration data. 【Product Introduction】 ■ Handheld Spectrum Analyzer MSA400 Series *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Spectrum Analyzer MSA400 Series ■ USB Cable MI400 ■ PC Software *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

External transfer of I/Q data measured with a signal analyzer.

[Application Example] I/Q data measured with the Signal Analyzer (MSA500 series) can be transferred to a PC or USB memory.

【Product Introduction】 ■Signal Analyzer MSA538 *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■Signal Analyzer MSA538 ■Lithium-ion Battery MB400 ■USB Cable MI400 ■PC Software MAS500 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Examples | Interference Wave Detection with Signal Analyzers

[Application Example] By using the power trigger function of the signal analyzer (MSA500 series), it is possible to detect and analyze interference waves.

【Product Introduction】 ■ Signal Analyzer MSA538 *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Signal Analyzer MSA538 ■ Lithium-ion Battery MB400 ■ USB Cable MI400 ■ Logging Software MAS500 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] Weather Radar Measurement Using Signal Analyzer

[Application Example] An example of radar wave measurement in weather radar using the trigger function of a signal analyzer.

When attempting to measure the modulation signals of weather radar using conventional spectrum analyzers, there were instances where measurements could not be made or data was missed due to the very short pulse width and brief occurrence time. As a tool to address these challenges, our handheld signal analyzer (MSA558) and 5GHz band antenna (M406) can measure the radio waves of weather radar with high precision. The hardware trigger of the MSA558 (IF level, power, external) has a time resolution of up to 14.7ns, significantly reducing the chances of missing intermittent signals. Additionally, it is capable of measuring 5GHz band wireless LAN (Note 1), which can be used, for example, to verify the DFS (Dynamic Frequency Selection) function during radar detection, which requires wireless LAN communication to cease within 10 seconds and switch to another channel. 【Product Introduction】 ■ Signal Analyzer MSA558 ■ Portable Antenna M406 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Visualization of modulated signals using a signal analyzer.

[Application Example] Various modulated signals can be visually observed using a handy real-time signal analyzer.

【Product Introduction】 ■ Signal Analyzer MSA538 *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Signal Analyzer MSA538 ■ Lithium-ion Battery MB400 ■ SMA-SMA Cable 1.5m MC303 ■ Conversion Adapter N(P)/SMA(J) MA306 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Optimization of weak signal measurement using a spectrum analyzer.

[Application Example] By optimizing the spectrum analyzer, it becomes possible to capture weak signals.

All spectrum analyzers are inevitably affected by noise generated internally. The average noise level defines the impact of this noise. This is an important factor when measuring weak signals, as it becomes impossible to measure signals that fall below the average noise level. Therefore, the key point is how effectively to keep this average noise level low. Additionally, if signals cannot be captured even after optimizing the settings of the spectrum analyzer, measurement can be made possible by amplifying the signal. 【Product Introduction】 ■ Signal Analyzer MSA538 ■ Low Noise Amplifier MAP302 *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Signal Analyzer MSA538 ■ Low Noise Amplifier MAP302 ■ PC Software MAS500 ■ Others (various cables, adapters, etc.) *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Methods to prevent erroneous measurements due to saturation of the spectrum analyzer.

[Application Example] This introduces a method to prevent erroneous measurements caused by saturation due to strong power signal inputs outside the measurement frequency band in a spectrum analyzer.

When a signal above an appropriate level is applied to the 1st mixer of the spectrum analyzer, saturation occurs, resulting in harmonic distortion and spurious signals, making accurate measurements impossible. Even signals outside the frequency measurement range can lead to incorrect measurements if they are above an appropriate level. 【Product Introduction】 ■ Spectrum Analyzer / Signal Analyzer *For more details, please refer to the PDF materials or feel free to contact us. 【System Configuration】 ■ Signal Analyzer MSA500 Series ■ Spectrum Analyzer MSA400 Series ■ Spectrum Analyzer MSA300 Series ■ Attenuators, filters, etc. *For more details, please refer to the PDF materials or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] C/N Ratio Measurement Using Channel Power Measurement

【Application Example】 Easily measure C/N ratio with a handy spectrum analyzer. Simplify the assessment of stable reception for digital broadcasts and more.

In digital modulation communication such as digital broadcasting, the carrier-to-noise ratio (C/N ratio) is an important indicator of whether stable reception can be achieved. A deterioration in the C/N ratio leads to a rapid increase in the bit error rate (BER), making it impossible to correctly reproduce the transmitted data. Our handheld spectrum analyzer MSA438 can measure this C/N ratio using the "channel power measurement" function. ● Accurate measurement and evaluation with a full-fledged spectrum analyzer ● Easy saving of measurement results (screen, data) to USB memory, simplifying report creation ● Handy type with easy settings for field use (compact, lightweight, battery-operated for 4 hours), no commercial power outlet required 【Product Introduction】 ■ Spectrum Analyzer MSA438 *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Spectrum Analyzer MSA438 ■ Dedicated Battery MB400 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Example: Telemetry Solution

[Application Example] Enables simultaneous reception of multiple channels in animal ecology research telemetry using a handheld spectrum analyzer.

In recent years, due to the increase in population of wildlife that is causing damage to agriculture and railways, telemetry transmitters are used for ecological surveys of these animals. In 2008, the "Radio Equipment for Animal Detection Reporting System of Specified Low Power Radio Stations in the 150 MHz Band" was enacted, and the 150 MHz band was allocated for telemetry transmitters. Typically, a dedicated receiver is used for exploration, but it can only observe one channel at a time. By using the MSA338 handheld spectrum analyzer, it is possible to observe multiple channels simultaneously, significantly improving survey efficiency. [Product Introduction] ■ Spectrum Analyzer MSA338 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Method for expanding the dynamic range of a spectrum analyzer equipped with a tracking generator.

[Application Example] Method for Expanding the Dynamic Range of Spectrum Analyzers Equipped with Tracking Generators (TG) Using Low-Noise Amplifiers

This introduces a method for expanding the dynamic range of spectrum analyzers equipped with a tracking generator (TG) by using a low-noise amplifier. 【Product Introduction】 ■ Signal Analyzer MSA538TG ■ Spectrum Analyzer MSA338TG ■ Spectrum Analyzer MSA438TG ■ Low Noise Amplifier MAP302 *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration