It can be used in pipelines that require the highest quality standards or in applications where thermowells are already installed. It is particularly suitable for piping conditions that are difficult to immerse in process media or involve very strict flow rate conditions. The connection ends are smooth and designed for easy welding. The process connection meets stringent hygiene requirements in terms of materials and design, and the sensor is removable for easy calibration and maintenance. <Product Details> - The removable measurement insert allows for easy removal of the thermometer. - The stainless steel head is optimized for hygiene and facilitates easy handling on-site. - Unique design allows for cleaning in any installation environment. - Outputs available for Pt100, 4-20mA, HART protocol, FOUNDATION, fieldbus, and PROFIBUS PA. - Wetted parts made of stainless steel 1.4435. - Minimization of dead space prevents contamination. For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis series of thermocouples complies with Chinese explosion-proof standards (CCC explosion-proof) and can be used without a protective tube, as well as in combination with various specifications of protective tubes. Designed with a unique measuring insert and spring shape that includes a spring in the center, it can be used in combination with various designs of connection heads, allowing for use with a variety of sensors. As this is a made-to-order product, the connection head, insertion length of the sheath, length of the connection part, and design of the protective tube can be customized according to the installation process conditions. <Product Features> - Sensor range: -40 to +1,200 °C - Compatible with many temperature transmitters, including field indicators - Can be mounted to a thermowell. - Replaceable spring-type measuring insert. - Explosion-proof specifications For more details, please refer to the product data sheet. 【CCC Explosion-Proof Compliant】TC / Thermocouple Model: TC10
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe TR12 temperature resistance sensor can be used without a protective tube, but it is also capable of measurement when combined with various specifications of protective tubes. Designed with a unique measuring insert that has a spring in the center and a spring shape, it can be used in combination with various designs of connection heads, allowing for use with a diverse range of sensors. As a made-to-order product, the connection head, insertion length of the sheath, length of the connection part, and design of the protective tube can be customized according to the installation process conditions. It is also compatible with international standards such as IECEx, GOST (Russia), INMETRO (Brazil), CCC (China), PESO (India), and Kosha (Korea). <Features> - Sensor temperature range: -196 ... +600 °C - Compatible with many temperature transmitters, including field indicators. - Can be installed in standard thermowells. - Replaceable spring-type measuring insert - Explosion-proof specifications - SIL2 compliant For other specifications, please refer to the catalog. 【CCC Explosion-proof Compatible】RTD / Temperature Resistance Sensor Model: TR12
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationApplications - Ideal for level measurement in non-vented tanks, especially for cryogenic applications - Monitoring of filter clogging - Monitoring and control of pumps - Gases and liquids with low viscosity Features - Differential pressure measurement range from 0 to 80 mbar to 0 to 1725 mbar - High operating pressure of 50 bar (static pressure) - Safety against overpressure up to 50 bar - Very compact design - Optional valve manifold with operating pressure display available
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationYou can use not only the CTP62x0 series Pt100 temperature probes but also your existing probes. We can also provide completely custom-made probes upon request. Various functions, including data logging, can be utilized. Each temperature probe is calibrated at WIKA's DKD-certified factory, and DKD/DAkkS calibration certificates can be issued without additional charges. <Product Specifications> - Probe Type: Pt100 (4-wire) - Insertion Point: 1 - Temperature Range: -50 ... +250 °C - Display: LC Display - Resolution: 0.01 K up to 200 °C, 0.1 K above that - Temperature Drift: ≤ 0.002 °C/K - Display Range: -99.99 to +99.99 °C or -199.9 to +650.0 °C - Power Supply: 9V battery - Continuous Operating Time: 20 hours - Ambient Temperature: -10 to 50 °C - Storage Temperature: -25 to +70 °C - Communication Interface: USB or RS-232 - Product Dimensions: Please refer to the dimensions diagram below. - Weight: 160 g For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn addition to processing signals from thermocouples, it also has adjustment features that minimize measurement errors thanks to a low-drift measurement amplifier. By performing physical calibration with probes and displays at 1 to 3 different temperatures, measurement errors can be minimized, maintaining high display accuracy. Each temperature probe is calibrated at WIKA's DKD-certified factory, and DKD/DAkkS calibration certificates can be issued without additional charges. <Product Specifications> - Input ports: 1 or 2 - Temperature range: -200 to +600 °C (PT100) -200 to +1,500 °C (temperature resistance) - Display: 4 1/2 digits, backlit LC display - Resolution: 0.1 K - Display range: -19999 to 19999 - Power supply: 9V battery - Continuous operating time: 20 hours - Ambient temperature: 0 to 40 °C - Storage temperature: -10 to 50 °C - Communication interface: USB - Product dimensions: 200 x 93 x 44 mm - Weight: 300 g For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Pt100 or thermocouple can measure temperatures from -200 to 1,500 °C. It can also be used as a reference device for customers with strict accuracy requirements. By calibrating between 1 to 3 different probes and the display, measurement errors can be minimized, achieving high-precision temperature readings. Humidity measurement can be performed by combining temperature-humidity probes, and flow measurement from 0.1 to 40 m/s can also be supported using a vane sensor. <Product Specifications> - Probe Type: Pt100, temperature resistance, humidity, flow - Input Ports: 1 or 2 - Temperature Range: -200 to 1,100 °C - Display: 4 1/2 digit, backlit LCD - Resolution: 0.01 K up to 200 °C, 0.1 K above that - Display Range: -19999 ... 19999 - Power Supply: 9V battery - Continuous Operating Time: 20 hours - Ambient Temperature: 0 ... 40 °C - Storage Temperature: -10 ... +60 °C - Communication Interface: USB - Product Dimensions: 200 x 93 x 44 mm - Weight: 350 g For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAchieves high precision through battery operation. The 2-channel mechanism allows for direct temperature measurement from Pt100 or thermistor probes and displays the temperature difference between the two channels. Data can also be saved to a PC using a USB port. <Product Specifications> - Probe Type: Pt100, Pt25 resistance thermometer, NTC thermistor - Number of Inputs: 2 - Temperature Range: -200 to +962 °C - Accuracy: Measuring resistance thermometer / 0.015 K - NTC Thermistor: 0 ... 400 Ω (±0.006 Ω) 400 Ω ... 50 kΩ (±0.01 % of reading) 50 ... 400 kΩ (±0.02 % of reading) - Display: 4 1/2 digit, backlit LC display - Resolution: 0.001 °C - Data Log: Up to 8,000 entries - Power Supply: Nickel-metal hydride battery - Continuous Operating Time: 20 hours - Ambient Temperature: 0 to 40 °C - Storage Temperature: -20 to +50 °C - Communication Interface: USB - Product Dimensions: 232 x 97 x 53 mm - Weight: 500 g
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CTP5000 is manufactured as a platinum resistance thermometer (PRT). We can custom-make the shape and material to meet customer specifications when off-the-shelf products do not meet their needs, so if you are considering custom manufacturing or if other vendors cannot accommodate your request, please feel free to contact us. Calibration data is saved, allowing for easy installation of SMART probes between channels and devices without the need to input calibration data into the currently used equipment. <Probe Basic Specifications> - Temperature Range: -196 to +660 °C - Resistance Value: 100 Ω at 0 °C - Temperature Coefficient: 0.00385 - R(Ga)/R(TPW): Below 1.11807 - Annual Drift: ±10 mK (varies by specification) - Recommended Measurement Current: 1 mA - Material: SUS (material changes can be made upon customer request) - Customers can freely choose the following regarding the probe: Probe Diameter Probe Length Cable Length Connection Size and Standard (standard is DIN plug) For other specifications, please refer to the data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt enables safe temperature measurement from a distance without contacting the object being measured. It is particularly ideal for applications where thermocouples or resistance temperature detectors cannot be used. The infrared handheld thermometer is highly regarded by many customers across a wide range of industries, such as machinery and plant service and maintenance, as well as food monitoring, for its ability to measure surface temperature safely and accurately. We recommend using this product in places where temperature significantly affects process safety and product quality. <Product Specifications> - Measurement Range: -60 to +1,000 °C - Accuracy: 2 K or 2% - Resolution: 0.1 °C, 1 °C for temperatures above 200 °C - Spectral Sensitivity: 6 to 14 µm - Measurement Distance: Up to 8 m - Emissivity: 0.01 to 1.00 - Optical Resolution: 50:1 - Response Time: < 1 s - Temperature Units: °C, °F - Power Supply: 2 x 1.5 V AA batteries - Ambient Temperature: 0 … 50 °C - Product Size (H x D x W): 203 x 197 x 47 mm - Weight: 386 g Please refer to the data sheet for other specifications.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CTR2000 can measure in either 2-channel or 8-channel configurations. The probes can accommodate 4-wire or 3/4-wire types, allowing you to choose according to your needs. The included probes feature enhanced functionality to achieve high operability and low life costs. For example, there is a function to save calibration data in the main memory. By simply connecting the probe to the connector, the specifications are instantly recognized, enabling data storage with the highest measurement accuracy. Additionally, it is possible to monitor the conditions of the surrounding environment during calibration. <Basic Specifications> - Accuracy: ±0.01℃ full range (4-wire platinum resistance thermometer) ±0.05℃ full range (3-wire platinum resistance thermometer) - Compatible with ITS90, EN60751 (DIN90), CVD temperature coefficients - Measurement range: -200 to 850℃ - Resolution: 0.001℃ - Stability: Below 0.005℃/year - Temperature units: ℃, F, K, Ω - Standard RS232C interface - Compatible with 4-wire and 3-wire platinum resistance thermometers For other specifications, please refer to the data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAccuracy: The high-precision digital thermometer CTR3000 model, with an accuracy of ±0.005 ℃, is one of the best in the industry for temperature calibration. It has a proven track record of numerous installations not only in Japan but also in overseas national agencies, public institutions, renowned large companies, and calibration firms across various industries. It can perform multi-point calibration with up to 44 channels, and its user-friendly touch panel display allows for easy operation. <Basic Specifications> - Accuracy: ±0.005℃ full range (4-wire platinum resistance thermometer) ±0.03℃ full range (3-wire platinum resistance thermometer) - Compatible with ITS90, EN60751 (DIN90), CVD (Calendar Bandusen) temperature coefficients (Pt) - Measurement range: -200 to 962℃ (Pt) / -210 to 1820℃ (TC) / 0 to 500kΩ (thermistor) - Resolution: 0.0001℃ / 0.00001Ω / 0.00001mV (depending on temperature range) - Temperature units: ℃, F, K, Ω, mV - USB interface standard equipment - Touchscreen For other specifications, please refer to the data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CTx9100 series portable calibrator is particularly suitable for on-site calibration, and its very compact design and lightweight make it easy to carry and use anywhere. Using dry well calibrators or micro-calibration baths for calibrating surface thermometers or non-contact thermometers may lead to incorrect values as they are not optimal applications, but with the CTM9100-150, you can confidently use such temperature calibrators. By using the included accessories and simply operating the keys and toggle switch, it can be calibrated as contact (TC, Pt, surface) or non-contact (infrared), and you can easily switch between four types of temperature calibration functions. Calibration temperature can be easily adjusted using two keys on the controller, allowing for very rapid control. The actual temperature and the set temperature can be displayed simultaneously on a large four-digit high-contrast LCD screen, minimizing the chances of misreading. Its very compact design and lightweight make it ideal for on-site calibration, allowing it to be carried and used anywhere.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CTB9400 and CTB9500 are the ideal temperature calibration baths for calibrating temperature probes regardless of location. When performing calibration, the test thermometer and reference thermometer are inserted into the calibration bath under the same temperature conditions. After reaching a stable temperature, the displayed values are read, or the output signals are measured for comparison calibration with the standard thermometer. To minimize measurement uncertainty in this comparison, a temperature control unit that ensures a uniform temperature distribution and constant temperature within the calibration range is necessary. The medium used in the liquid chamber is silicone oil, which has high thermal conductivity, low viscosity, is inert over a wide temperature range, has low vapor pressure, is resistant to chemical decomposition, and is difficult to ignite, in order to maintain a uniform temperature distribution. The temperature range is from -45 to +300°C, with two versions available: CTB9400: 28 to 300 °C CTB9500: -45 to +200 °C The temperature-controlled tank is designed to be 200mm, which is generally said to reduce heat dissipation errors and minimize measurement uncertainty. It is the optimal temperature calibration bath for calibrating temperature probes regardless of location.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration<Display> - Display: 4-digit LED display - Temperature range: -35 ... +225 °C - Accuracy: 0.2K - Stability: < 0.05 K - Resolution: 0.01 up to 100°C, thereafter 0.1 <Temperature Control> - Heating time: 10 minutes (from 20 °C to 225 °C) - Cooling time: 30 minutes (from 225 °C to 20 °C) - Stabilization time: depends on temperature and insertion length <Insertion Part> - Insertion depth: 150 mm - Insertion part dimensions: Ø 60 x 165 mm - Constant temperature bath volume: 0.6 liters <Power Supply> - Power supply: AC 100 ... 240 V, 50/60 Hz - Power consumption: 375 VA or 1,100 VA - Fuse: 6.3 A or 10 A slow-blow fuse (AC 250 V) - Power cord: AC 230 V <Other> - Interface: RS-485 - Product size (W x H x D): 215 x 305 x 425 mm - Weight: 12.5 or 7.5 kg - Complies with CE mark, EAC, GOST standards For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CTD9100 is particularly ideal for on-site calibration and is a very user-friendly temperature calibrator. Its compact and lightweight design allows for easy transport and use anywhere. A major feature is the combination of a stable heat source and high-precision Pt100 temperature measurement, which enables even more efficient calibration using temperature probes. By regularly monitoring the temperature probes, it allows for quick detection of failures and helps reduce downtime. Calibration can be performed using a temperature-controlled metal block and interchangeable inserts. Calibration temperatures can be quickly set using just two buttons, and the actual temperature and set temperature are displayed simultaneously on a large, high-contrast four-digit LCD, preventing misreading. Thermometers with different sheath diameters can be inserted into the calibrator using the included inserts. Additionally, the unique block design significantly improves uniformity in the low-temperature range, resulting in very small measurement uncertainty. Furthermore, the calibration bus allows for a 150 mm insertion, greatly reducing heat dissipation errors.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CTD9100 is particularly ideal for on-site calibration applications, and its user-friendly, compact, and lightweight design allows it to be easily transported and used anywhere. By enabling easy regular calibration of temperature probes, it can reduce production downtime due to failures. The freezing point calibrator not only operates at 0°C but also allows for simultaneous calibration at other test temperatures thanks to its active cooling feature. As a product concept, it combines a stable temperature source with high-precision Pt100 temperature measurement, making the calibration of industrial temperature probes more efficient and quicker. This calibration bath can be easily set to cold junction temperatures for extended periods, simplifying the calibration of thermocouples. It not only eliminates the complexities of conventional water fixed-point cells but also mitigates the risk of freezing or damage during transport. The design and control mechanism maintain a uniform temperature distribution within the block. This ensures that temperature variations do not occur across the seven test holes, allowing for a consistent temperature distribution environment and reducing the impact of measurement uncertainty.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt features a sturdy case and a compact size, making it convenient for portability. With a stable heat source and a high-precision Pt100 combination, it allows for efficient calibration. It can quickly detect faults, helping to avoid and reduce downtime. <Display Information> - Temperature Range: tamb … 375 °C - Accuracy: ± 0.5 ... 0.8 K - Stability: ± 0.05 K to 100 °C - Resolution: 0.1 °C <Temperature Control> - Heating Time: 6 minutes (from 20 °C to 300 °C) - Cooling Time: 14 minutes (from 300 °C to 60 °C) - Stabilization Time: 5 minutes <Insertion Part> - Insertion Depth: 100 mm - Insertion Part Size: Ø 13 x 100 mm <Power Supply> - Power Supply: AC 230 V, 50/60 Hz or AC 110 V, 50/60 Hz - Power Consumption: 250 VA <Other> - Interface: RS-232 - Product Size: 149 x 74 x 155 mm - Weight: 1.7 kg - Complies with CE mark, EAC, and GOST standards For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt offers high precision and excellent control stability, making it ideal for automatic testing and calibration standards of various types of high-pressure measuring instruments. It can also perform auto-frettage processing and periodic pressure load testing. The air control circuit requires compressed air, and the output side can be either oil or water, but other media can also be used according to requirements. The sensor can be removed from the front, eliminating the need to take the controller out of the calibration testing device. <Product Specifications> - Pressure Range: 0 … 160 MPa * Equipped with a safety relief valve for overpressure protection - Control Stability: 0.005% FS - Accuracy: 0.01% FS - Calibration Interval: 365 days - Setting Units: 38 units and two user-defined units - 9” Color LCD Display, Touchscreen - Resolution: 4 … 7 digits - Supply Pressure Media: Air or N2 - Power Supply: AC 100 ... 110V / 200 ... 240V, 50/60Hz - Power Consumption: 130 VA - Interface: IEEE-488.2, Ethernet, USB, RS-232 For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPC8000 is a high-pressure compatible pressure controller with a maximum accuracy of 0.008% IS-33. The pressure range is from -100 kPa to 40 MPa. It achieves precise measurements with up to three removable transducers and one standard atmospheric pressure gauge. Thanks to its software functionality, it can be replaced with pressure controllers from other manufacturers. <Product Specifications> - Pressure Range: -100 kPa to 40 MPa - Maximum Accuracy: 0.008% IS-33 - Control Stability: <0.002% FS - Uncertainty: 0.008% - Calibration Interval: 365 days - Setting Units: 38 units and two user-defined units - 9” Color LC Display, Touchscreen - Resolution: 1 to 10 PPM - Supply Pressure Medium: Air or N2 - Power Supply: AC 100 ... 110V / 200 ... 240V, 50/60Hz - Power Consumption: 120 VA For more details, please refer to the product data sheet. [Accuracy: 0.008%] Precision Pressure Controller CPC8000
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPC6050 can accommodate up to two sensors and regulators, each of which can be controlled independently. An atmospheric pressure sensor can also be integrated, allowing for switching between atmospheric pressure, absolute pressure, and gauge pressure displays. It offers many applications for calibration, production processes, and more. <Specifications> - Pressure range: -100 kPa to 21 MPa - Gauge pressure: 0...21 kPa to 21 MPa - Differential pressure: -1.2 kPa...1.2 kPa to -100 kPa to 21 MPa - Absolute pressure: 50 kPa to 21.1 MPa - Accuracy: FS ±0.01% or 0IS-50 - Calibration interval: 365 days - Setting units: 38 units and two user-defined units - 8.9” color LC display, touch screen - Resolution: 4...6 digits - Supply pressure media: Air or N2 - Power supply: AC 100–110V / 200–240V, 50/60Hz - Power consumption: 120 VA - Interfaces: Ethernet, IEEE-488, USB, RS-232, WiFi For more details, please refer to the product data sheet. Portable Pressure Controller Model CPC6050
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe portable pressure controller CPC4000 features: - A wide pressure range from -100 kPa to 21 MPa - Up to 2 built-in sensors - Switching between atmospheric pressure, absolute pressure, and gauge pressure display <Specifications> - Pressure range: 0.02% FS or IS-50 - Gauge pressure: 0...35 kPa to 21 MPa - Differential pressure: -100 kPa...1 MPa to -100 kPa ... 21 MPa - Absolute pressure: 0...100 kPa to 21.1 MPa - Accuracy: FS±0.02% or 0IS-50 - Calibration interval: 365 days - Setting units: 38 units and two user-defined units - 7.0” color LCD display, touch screen - Resolution: 4 to 6 digits - Supply pressure medium: Air or N2 - Power supply: AC 100–110V / 200–240V, 50/60Hz - Power consumption: 120 VA - Interfaces: Ethernet, IEEE-488, USB, RS-232, WiFi For more details, please refer to the product data sheet. Portable Pressure Controller CPC4000
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA pressure calibrator and controller that excels in measuring low pressure. It is a battery-operated pressure controller that generates pressure set by automation. The pressure generation uses a built-in electric pump and can handle both positive and negative pressure. <Product Specifications> - Pressure Range (mbar): 0–1, 0–10, 0–50, 0–100, 0–500, 0–1,000 - Accuracy: FS ±0.3% or 0.1% - Calibration Interval: 365 days - Setting Units: Pa, kPa, hPa, bar, mbar, psi, inH2O, inHg, mmHg, Torr - Overpressure Protection: FS x 5 times or 2 times - Size: 102.6 x 257 x 271 mm - Weight: 4.6 kg - Internal Pressure Supply: Electric pump - IP Rating: IP20 - Resolution: 4 ... 5 digits - Supply Medium: Air - Wetted Materials: Ni, Al, CuBe, PUR - Power Supply: DC 24 V, 1A - Power Consumption: 24 VA For more details, please refer to the product data sheet. Portable Low Pressure Controller Model CPC2000
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPG2500 is used when high-precision pressure measurement is required for accuracy verification, manufacturing, testing, and calibration of pressure instruments. It can be used to display atmospheric pressure by adding an atmospheric reference sensor or to emulate gauge or absolute pressure. The reading percentage for each range can be configured to be continuous, allowing for accuracy in reading percentages over a wide range. Each sensor is removable, enabling recalibration or range changes without stopping operation. <Specifications> - Range: Built-in sensor: can be set arbitrarily between 0 to 289 MPa External sensor: can be set arbitrarily between 0 to 100 MPa - Output: RS-232, USB, GPIB, Ethernet - Resolution: 4 to 7 digits - Accuracy: 0.03% FS to 0.008% IS-33 - Temperature: 15 to 40 °C - Pressure media: Gas, water, oil, and others upon consultation - Number of channels: Up to 3 ch (built-in 0 to 2 ch + external 0 to 3 ch) - Display digits: 4 to 7 digits - Pressure type: Gauge pressure, compound pressure, absolute pressure For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPA2501 displays altitude, true airspeed, vertical true airspeed, and true air acceleration, and can be used when high precision is required for the calibration of altimeters and airspeed indicators in avionics displays or calibration equipment. The CPA2501 has an altitude channel and a true airspeed channel consisting of Ps/Pt or Ps/Qc, and can be configured as a single channel altitude/altitude rate indicator (Ps only) or a true airspeed/ground speed rate indicator (Qc only), or as a unit configuration of Ps/Pt or Ps/Qc, and can also be equipped with an optional barometer. <Specifications> - Measurement range: 0 to 950 mbar abs. up to 0 to 1,253 mbar abs. 0 to 1,355 mbar abs. up to 0 to 3,725 mbar abs. -34 to +100 mbar up to -34 to +3,386 mbar For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis pressure sensor provides high-precision pressure measurement with a 2-wire 4-20mA output, achieving 0.025% FS accuracy across the entire pressure range and compensation temperature range. It also features an output with a reading speed of 21 times per second (47ms). <Product Specifications> - Gauge Pressure: -125 mbar to 0 ... 1,000 bar - Absolute Pressure: 0 ... 350 mbar abs to 0 ... 1,001 bar abs - Accuracy: 0.015% Full Span - Recommended Calibration Span: 365 days - Connection: SAE J514/JIC or Autoclave F250C; for pressure ranges > 400 bar 10-32 UNF female - Allowable Temperature Medium Temperature: -40 ... +85℃ Compensation Temperature Range: -20 ... +75℃ Storage Temperature: -40 ... +85℃ - Allowable Humidity: 0 ... 95% r.h. - IP Rating: IP67 - Weight: 250 g For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe high-precision pressure sensors CPT6100 / 6180 can be freely set within a measurement range of -1 to 400 bar, with a maximum accuracy of 0.01% IS-50. Their robust and compact design allows for easy installation without the need for additional seals. <Product Specifications> - Gauge Pressure: -35 mbar to 0 ... 400 bar - Absolute Pressure: 0 ... 500 mbar abs to 0 ... 401 bar abs - Accuracy: 0.01% IS-50 or 0.01% Full Span or 0.03% Full Span - Recommended Calibration Span: 180 days or 365 days - Connection: 7/16-20 SAE for pressure and reference port - IP Rating: IP67 - Weight: 505 g <Permissible Temperature> - Media Temperature: 0 to +60℃ - Compensated Temperature Range: 15 to +45℃ - Storage Temperature: -20 to +70℃ - Permissible Humidity: 0 to 95% r.h. (without condensation) For more details, please refer to the product data sheet. High-precision pressure sensor Models: CPT6100 / 6180
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationResponse speed of 250 Hz (4 ms), pressure range of -1 to +400 bar, can be used for 365 days without recalibration with a maximum accuracy of 0.025%. The standard interface is RS-232, and it can also be changed to RS-485. It has a robust and compact design, easily integrated into a 19-inch rack without the need for additional sealing. <Product Specifications> - Gauge pressure: -35 to 70 mbar to 0 to 400 bar - Absolute pressure: 0 to 500 mbar abs to 0 to 401 bar abs - Accuracy: 0.025% IS-50 or 0.025% Full Span - Recommended calibration span: 180 days or 365 days - Connection: 7/16-20 SAE for pressure and reference port - IP rating: IP67 - Weight: 505 g <Temperature Range> - Media temperature: 0 to +60℃ - Storage temperature: 0 to +70℃ - Humidity tolerance: 0 to 95% r.h. For more details, please refer to the product data sheet. High-speed response and high-precision pressure sensor Models: CPT6140
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a pressure sensor with electronically compensated pressure linearity, achieving an accuracy of 0.020% FS. The accuracy includes linearity, hysteresis, repeatability, and temperature error, and it outputs at a reading speed of 50 times per second (every 20 milliseconds). The interface is RS-232 or RS-485, with the option to select from four different baud rates using the multi-drop feature in RS-485. <Product Specifications> - Gauge Pressure: 0 ... 25 mbar to 0 ... 100 bar - Absolute Pressure: 0 ... 350 mbar abs to 0 ... 1,001 bar abs - Accuracy: 0.020% Full Scale - Recommended Calibration Span: 185 days - Connection: SAE J514/JIC or Autoclave F250C; > 400 bar - IP Rating: IP67 - Weight: 250 g <Permissible Temperature> - Media Temperature: 0 ... +50℃ - Ambient Temperature: -40 ... +85℃ - Storage Temperature: -40 ... +85℃ - Permissible Humidity: 0 ... 95% r.h. (without condensation) For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe ultra-high precision pressure sensor CPT9000 offers high accuracy of 0.008% (IS-33), a temperature compensation range of 0 to 50 °C, and is capable of measuring pressures from 25 mbar to 1,001 bar. The interfaces support RS-232 and RS-485, with the RS-485 allowing the selection of three different baud rates through its multi-drop functionality. <Pressure Range> - Gauge Pressure: 0 to 25 mbar to 0 to 100 bar - Absolute Pressure: 0 ... 350 mbar abs to 0 ... 1,001 bar abs - Accuracy: 0.008% IS-33 or 0.008% Full Span - Recommended Calibration Span: 365 days - Connection: SAE J514/JIC 4 or Autoclave F250C; > 400 bar - IP Rating: IP67 - Weight: 250 g <Permissible Temperatures> - Media Temperature: 0 to +50℃ - Ambient Temperature: -40 to +85℃ - Storage Temperature: -40 to +85℃ - Permissible Humidity: 0 to 95% r.h. (without condensation) For more details, please refer to the product data sheet. Ultra-high precision pressure sensor Models: CPT9000
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationYou can connect it to a PC with a USB interface via a USB adapter. It has a measurement range of up to 1,000 bar and automatically captures measurement results along with maximum and minimum values over a span of 1 ms to 10 s. Pressure range: 0 … 25 mbar to 0 … 1,000 bar Pressure units: mbar, bar, Pa, kPa, MPa, mmHg, psi, inHg (0 °C), inHg (60 °F), mWs <Specifications> - Connection: G1/2 - Accuracy: ≤ 0.2 % of span/10 K (0.1% option available) - Weight: 120 g <Permissible Temperature> - Medium temperature: -25 ... +100℃ - Ambient temperature: -20 ... +80℃ - Storage temperature: -40 ... +100℃ - Permissible humidity: 0 ... 95 % r. h. (no condensation) For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP-7000, which generates a pressure of up to 700 MPa, is a hand pump that enables rapid pressure supply, smooth pressure generation, and fine pressure adjustment. It can be used in laboratories, workshops, or on-site as a pressure source for testing, adjusting, and calibrating pressure measuring instruments through comparative measurements. When connecting the test specimen and the reference pressure measuring instrument, the same pressure is supplied to the measuring instrument, allowing for high-pressure comparative calibration. The spindle operates within the pump body, resulting in a compact and lightweight design, while the very robust ABS resin case makes it suitable for on-site use. <Specifications> - Supply pressure range: 0 ... 7,000 bar - Pressure supply medium: Mineral oil - Pressure supply port: Includes a sealing cone with a freely rotatable 2 × knurled nut G ¾ female thread, as well as a replaceable adapter to M16 x 1.5 male with a sealing cone. - Pump size: (L x W x H) 460 x 445 x 265 mm - Weight: 32.5 kg For more details, please refer to the product data sheet. 【Maximum supply pressure: 700 MPa】Hydraulic comparison test pump CPP7000-X
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt generates a pressure of up to 400 MPa and can be used as a pressure source for testing, adjusting, and calibrating pressure gauges through comparative measurements. Its design, with a spindle operating within the pump body and a robust ABS resin case that is compact and lightweight, makes it suitable for use not only in laboratories and workshops but also in the field. When connecting the test item to a high-precision reference pressure measuring device, the same pressure is supplied to both gauges. By comparing two measurements at any pressure value, accuracy verification and adjustments can be performed. With the built-in dual-area spindle pump featuring a switching valve, it allows for rapid pressure supply and smooth pressure generation while also enabling fine adjustments of the pressure. <Specifications> - Supply pressure range: 0 ... 4,000 bar - Pressure supply medium: Mineral oil - Pressure supply ports: G1/2 male thread union nut, metal cone specification, 2 locations - Pump size: (L x W x H) 401 x 397 x 155 mm - Weight: 13.5 kg For more details, please refer to the product data sheet. 【Maximum supply pressure: 400 MPa】Hydraulic comparison test pump CPP4000
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP1600 is a hydraulic comparison test pump with a maximum supply pressure of 160 MPa, serving as a pressure generation source for testing, adjusting, and calibrating pressure measuring instruments for comparison and calibration purposes. It can primarily be used for confirming the operation of pressure gauges in laboratories, workshops, and production sites. Even at high pressures, it allows for smooth operation of the hand spindle, and the body size does not change when the pump is operated. By connecting the target instrument and a high-precision reference measuring instrument, the same pressure is supplied to both measuring devices when the pump is activated. By comparing two measurements at any pressure value, accuracy verification and adjustment of the test equipment can be performed. <Specifications> - Supply pressure range: 0 ... 1,000 bar or 0 ... 1,600 bar - Pressure supply medium: Mineral oil - Pressure supply ports: 2 G1/2 male threads - Pump size: (L x W x H) 400 x 375 x 265 mm - Weight: 20 kg For more details, please refer to the product data sheet. 【Maximum supply pressure: 160 MPa】Hydraulic comparison test pump CPP1600
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP1200-X is a comparison calibration pump capable of generating a maximum pressure of 120 MPa. It is suitable for use in laboratories, workshops, and on-site as a pressure source for testing, adjusting, and calibrating pressure measuring instruments through comparative measurements. When connecting the test instrument and a high-precision reference pressure gauge, the same pressure is supplied to both measuring devices. By comparing two measurements at any pressure value, accuracy checks and adjustments of the pressure measuring instruments can be performed. The switching valve allows for smooth pressure generation, while the precisely adjustable spindle pump enables fine-tuning of the pressure. A circuit diagram for pressure supply is displayed on the device base, allowing for quick and easy operation. <Specifications> - Supply pressure range: 0 ... 1,200 bar - Pressure supply medium: Mineral oil - Pressure supply ports: 2 G1/2 male threads - Pump dimensions: (L x W x H) 401 x 397 x 155 mm - Weight: 13.5 kg For more details, please refer to the product data sheet. 【Maximum supply pressure: 120 MPa】Hydraulic comparison test pump CPP1200-X
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a pneumatic comparison test pump designed to supply pressure up to 120 bar. It can be used in laboratories, workplaces, or on-site as a pressure source for comparative testing, adjustment, and calibration of pressure measuring instruments. When a test instrument is connected to a reference pressure measuring instrument with sufficient accuracy, the same pressure is supplied to both measuring instruments. By comparing two measurements at any pressure value, accuracy verification and adjustment of pressure measuring instruments can be performed. It is equipped with two precision metering valves for the pressure inlet and outlet, allowing for precise pressure settings in accurate comparison tests, and includes an adjustable feature for fine-tuning. The connection for external pressure or vacuum sources is located on the rear panel. <Specifications> - Supply pressure range: 0 ... 120 bar - Pressure supply source: Air - Pressure supply ports: 2 G1/2 male threads - Pump size: (L x W x H) 510 x 490 x 210 mm - Weight: 22 kg For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP1000 model of the hydraulic comparison calibration pump is a pressure generator for pressure gauge comparison tests, adjustments, and calibration applications, with a maximum supply pressure of 100 MPa. <Specifications> - Supply pressure range: 0 ... 1,000 bar - Pressure supply medium: mineral oil or fresh water - Pressure supply ports: 2 G1/2 male threads <Pump Size: (L x W x H)> - CPP1000-M: 420 x 280 x 103 mm - CPP1000-L: 420 x 240 x 103 mm <Weight> - CPP1000-M: 6.3 kg - CPP1000-L: 5.6 kg For more details, please refer to the product data sheet. 【Maximum supply pressure: 100 MPa】Hydraulic comparison calibration pump CPP1000
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP700/1000 can be used as a pressure pump for testing, adjusting, and calibrating mechanical and electronic pressure measuring devices through comparative measurement. It enables pressure testing in laboratories as well as on-site in plants and factories. Despite its very compact size, it can easily and accurately generate high pressures of up to 700 bar or 1,000 bar. Additionally, the pump is equipped with a fine adjustment valve to allow for precise comparative testing. <Product Specifications> - Supply pressure range: 0...700 bar or 0 ... 1,000 bar - Pressure supply source: air, hydraulic oil, fresh water - Pressure supply port: hose with G1/4 male thread connection or G1/2 male thread section - With fine adjustment valve - Pump size: (L x W x H) 280 x 170 x 120 mm - Weight: 1.9 kg For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP30 can be used as a pressure generator for testing, adjusting, and calibrating mechanical and electronic pressure measuring devices through comparative measurement. It is equipped with a fine adjustment valve that allows for precise adjustment at the pressure measurement point. This is a pneumatic hand test pump that can switch to generate a vacuum up to -0.95 bar and supports a pressure range of up to 35 bar. <Product Specifications> - Supply pressure range: -0.95 ... +35 bar - Pressure supply source: Air - Pressure supply port: Hose with G1/4 male thread connection or G1/2 male thread section - With fine adjustment valve - Pump size: (L x W x H) 220 x 105 x 63 mm - Weight: 510 g For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CPP7-H can be used as a pressure generator for testing, adjusting, and calibrating mechanical and electronic pressure measuring instruments through comparative measurement. It is compact and portable. - Supply pressure range: -0.8 ... +7 bar - Pressure supply source: Air - Pressure supply ports: 1 port, 2 ports when using a T-connector - With fine adjustment valve - Pump size: (L x W x H) Without T-connector: 175.3 x 111 x 41 mm With T-connector: 175.3 x 144 x 41 mm - Weight: Without T-connector: 293 g With T-connector: 334 g For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Pascal ET, ideal for on-field testing and calibration of industrial measuring instruments, consists of up to two input/output modules and a HART communication-compatible module. <Specifications> - Pressure range: -900 mbar ... 100 bar - Temperature range: -200 ... 850 ℃ - Voltage: DC 80V - Current: DC 100mA - Resistance: 1,000Ω - Frequency: 50,000Hz - Units: bar, mbar, psi, psf, Pa, hPa, kPa, MPa, torr, atm, kg/cm², kg/m², mmHg (0 °C), cmHg (0 °C), mHg (0 °C), inHg (0 °C), mmH2O (4 °C), cmH2O (4 °C), mH2O (4 °C), inH2O (4 °C), ftH2O (4 °C) <Operating Conditions> - Ambient temperature: -10 ... +60 °C - Storage temperature: -20 ... +80 °C - Humidity: 0 ... 90 % r. h. (no condensation) - IP rating: IP54 For more details, please refer to the attached data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Pascal 100 consists of a maximum of two input/output modules and a HART communication-compatible module. By measuring/simulating electrical signals, temperature, and up to six pressure sensors, operators can configure the calibrator according to specific requirements. <Product Specifications> - Pressure range: -900 mbar ... 100 bar - Temperature range: -200 ... 850 ℃ - Voltage: DC 80V - Current: DC 100mA - Resistance value: 1,000Ω - Frequency: 50,000Hz - Units: bar, mbar, psi, psf, Pa, hPa, kPa, MPa, torr, atm, kg/cm², kg/m², mmHg, cmHg, mHg, inHg, mmH2O, cmH2O, mH2O, inH2O, ftH2O <Operating Conditions> - Ambient temperature: -10 ... +60 °C - Storage temperature: -20 ... +80 °C - Humidity: 0 ... 90 % r. h. (no condensation) - IP rating: IP54 Please refer to the data sheet for product details.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe current model is CPH8000 (Pascal100, PascalET). The CPH7650 is designed not only for testing in fixed workspaces and laboratories but also to be portable and compact in size. <Product Specifications> - Pressure range: -1 ... 200 bar - Supply pressure range: -0.85 … +25 bar - Current value range: DC 0 … 1 V; DC 0 ... 2 V; DC 0 ... 5 V; DC 0 ... 10 - Units: mbar, bar, psi, Pa, kPa, hPa, MPa, mmHg, cmHg, inHg, mmH2O, kg/cm², kp/cm², lbf/ft², kN/m², atm, Torr, micron, g/l (20 °C), kg/m³ (20 °C), any pressure unit of your choice Operating conditions: - Ambient temperature: -10 ... +50 °C - Storage temperature: -20 ... +60 °C - Humidity: 35 ... 85 % r. h. (no condensation) - Accuracy: max FS ±0.025% - IP rating: IP67
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a portable high-precision pressure calibrator that achieves an accuracy of 0.025%, capable of not only pressure measurement and transmitter calibration/verification but also temperature calibration. It can be used in explosion-proof areas and allows for the operation check of pressure switches and setting of contacts. An optional built-in reference pressure sensor enables manual generation of pressure up to +25 bar. It is also possible to simultaneously supply power to external transmitters via an electrical module and measure their output signals. Calibration results can be sent, evaluated, and stored completely paperless through dedicated software. <Product Specifications> - Pressure Range: -0.25 ... 10,000 bar - Supply Pressure Range: -0.85 … +25 bar - Accuracy: Max FS ±0.025% - IP Rating: IP54 category 2 <Operating Conditions> - Ambient Temperature: -10 ... +50 °C 0 ... +40 °C - Storage Temperature: -20 ... +50 °C - Humidity: 0 ... 85 % r. h. (without condensation) - Media Temperature: -30 ... +125 °C
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can be used with pressure sensors that have a maximum accuracy of 0.025% and can handle up to 600 MPa. The reference pressure sensor can also be used with external pressure supply. When changing the pressure sensor, the main unit automatically recognizes it, so no reconfiguration is necessary. Each operation is recorded, allowing for the recording of calibration data from multiple calibrations or the automatic calculation of switch hysteresis, for example. <Product Specifications> - Pressure Range: -0.1 to 600 MPa - Units: mbar, bar, psi, Pa, hPa, kPa, MPa, mmHg, cmHg, inHg, mmH2O, cmH2O, mH2O, inH2O, kg/cm², any pressure unit of your choice - Accuracy: Maximum FS ±0.025% - IP Rating: IP65 - Operating Modes: Calibration, Switch Test, Pressure Measurement <Usage Conditions> Ambient Temperature: 0 ... +50 °C Storage Temperature: -20 ... +70 °C Humidity: 0 ... 85 % r. h. (no condensation) Media Temperature: -20 ... +80 °C For more details, please refer to the product data sheet.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration