136~180 item / All 249 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online136~180 item / All 249 items
The particle diameter of a true sphere is uniquely determined. However, non-spherical particles can vary in size depending on the measurement method. For example, ground materials have different shapes for each individual particle. Therefore, to determine the overall size of a powder from individual particle diameter measurements, it is necessary to measure a large number of particles using the same method and statistically determine the particle size. In visual inspection or image analysis, it is common to measure the "equivalent diameter," which is the size of a particle with an ideal shape (usually circular) equal to the projected area of the particle, or the "directional diameter," which measures the length in a specific axial direction for randomly oriented particles. Additionally, there is the aspect ratio, which represents the ratio of the long axis to the short axis of the particle. Our particle size distribution measurement device measures particles as aggregates, so it cannot be discussed on the same level as measurements taken with microscopes and similar instruments. Among the Microtrack methods, the laser diffraction method outputs the particle size distribution of an aggregate of spherical particles that exhibit a scattering pattern equivalent to the obtained light scattering pattern. The dynamic light scattering method outputs the sphere-equivalent diameter based on diffusion. *For more details, please refer to the related links or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA powder is defined as "an extremely large collection of solid particles, in which appropriate interaction forces are acting between each particle." This is a qualitative definition, so there are quite vague points, but in short, it refers to what we visually perceive as powder and behaves like powder. The greatest feature of powder measurement is that it measures a collection of fine particles. In the case of particle size measurement, it is rare for all the measured fine particles to be of the same size. Most are collections of particles of varying sizes, more or less. To measure this and accurately represent it, it is necessary to statistically process the particles as a collection and express what sizes of particles exist in what proportions. *For more details, please refer to the related links or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMicrotrack Bell Co., Ltd. will hold a webinar on "Handling and Characterization of All-Solid-State Battery Materials" on Thursday, September 2, 2021. This webinar will focus on grinding (ball milling) in material synthesis and measurement techniques for powder properties. We welcome everyone, from those already involved in all-solid-state batteries to those who wish to learn more about them. ■ To participate, please proceed to the ZOOM registration page via the link to the [Application Page] below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of sugar. The standard method for measuring the particle size distribution of sugar is sieving in accordance with the ICUMSA Method GS2/9-37, and equivalent results have been obtained in round robin tests conducted across multiple laboratories. However, in practice, each laboratory follows slightly different procedures from the ICUMSA Method guidelines, resulting in significantly different particle size distributions measured by different labs, which is a concern. [Contents (excerpt)] - Sugar sieving - Systematic errors - Hardware-related issues - Human operational errors - Dynamic image analysis *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of synthetic diamonds. Diamonds are among the hardest materials found in nature and are mined as natural ores. The particle size distribution and particle shape of diamond abrasives are crucial for determining the efficiency of grinding tools, making their characterization very important. The "CAMSIZER M1" enables high-resolution particle characterization even for very fine diamond particles. [Contents (excerpt)] - Industrial diamonds - Static image analysis using CAMSIZER M1 - Data comparison with laser diffraction and scattering devices - Features of CAMSIZER M1 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of toner particles. Toner is a coloring particle primarily used in electrostatic printing, such as copiers and laser printers, and consists of very fine powder made up of particles ranging from 5 to 30 μm. It has fluidity and behaves like a liquid. It is composed of various auxiliary materials such as synthetic resins, pigments, and magnetic particles, and the demands for performance and quality of toner have become very high in order to achieve high-resolution printing performance. [Contents (excerpt)] ■ Applications ■ Static Image Analysis Device CAMSIZER M1 ■ Sample Preparation ■ Measurement Results ■ Particle Image Analysis *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution of ferrosilicon. Ferrosilicon (FeSi) is an alloy of iron and silicon, with a silicon content ranging from 10% to 90%. In steel manufacturing, it is used as a master alloy added in small amounts to adjust the melting, cooling processes, and the properties of the finished product. [Contents] ■ Applications ■ Dynamic Image Analysis Device CAMSIZER P4 ■ Measurement Examples: Differences by FeSi Grade ■ Summary ■ Features of CAMSIZER P4 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of needle-like crystals. Wollastonite is a colorless chain silicate found in metamorphic rocks, formed when impure limestone is exposed to temperatures above 600°C. Two types of Wollastonite were measured using the static image analysis device 'CAMSIZER M1', and the particle size distribution and particle shape were evaluated. [Contents (excerpt)] ■ Mineral: Wollastonite ■ Static image analysis using CAMSIZER M1 ■ Sample preparation and measurement ■ Measurement results ■ Evaluation of individual particles *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of extruded products. The particle width of extruded products is ideally uniform, but in reality, it is not necessarily uniform due to factors such as the mold opening being blocked by particle adhesion or the effects of contraction and expansion after extrusion. The dynamic image analysis device "CAMSIZER P4" can measure the amount of dust contamination, damage to extruded products, bending, fusion, and deformation of particles, as well as improper cuts of edges indicating blade wear. [Contents (excerpt)] ■ Extruded products ■ Major and minor axes ■ Dynamic image analysis device CAMSIZER P4 ■ Measurement examples of extruded products ■ Summary *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of spray-dried particles. In spray drying, milk is first pasteurized at low temperatures, then transferred to a spray tower, where it is dispersed into hot air at approximately 200°C from the nozzle. The droplets quickly lose almost all of their remaining moisture, reducing the moisture content from 87.5% to 3%, resulting in a fine powder. [Contents] ■ Granulation by spray drying ■ Advantages of dynamic image analysis in powdered milk measurement ■ Measurement example 1: Powdered milk ■ Measurement example 2: Powdered cream ■ Summary *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution and particle shape of superabsorbent polymers (SAPs). Superabsorbent polymers are granular polymers that have the ability to absorb liquids up to 500 times their own weight. Different particle size distributions of polymer granules are required depending on the application, so managing particle size distribution is very important in the quality control process. [Contents (excerpt)] ■ Extruded products ■ Manufacturing of superabsorbent polymers ■ Measurement example 1: Suitable measurement methods for SAP ■ Example 2: Reproducibility and equipment calibration ■ Example 3: Measurement of particle shape ■ Summary *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of abrasives and grinding grains. The "CAMSIZER X2" is based on dynamic image analysis and can measure not only high-precision particle size distribution but also particle shape. With very simple operation, the measurement time is only 2 to 3 minutes. It can evaluate the characteristics of both macrograins and micrograins. [Contents (excerpt)] ■ Applications ■ Quality control of abrasives ■ Measurement example 1: Measurement of micrograins using compressed air dispersion ■ Measurement example 2: Comparison with macrograins_sieving ■ Measurement example 3: Detection of coarse particles *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of pharmaceutical products. In the pharmaceutical field, evaluating the characteristics of the constituent particles is very important. For measuring the particle size distribution of active ingredients and excipients, methods such as sieving and laser diffraction/scattering are used, but these methods also have drawbacks. The image analysis of the 'CAMSIZER X2' is an alternative measurement method that overcomes these drawbacks. With a wide measurement range from 0.8μm to 3000μm, it allows for the evaluation of the characteristics of granules and powders within 3 minutes. [Contents] ■ Introduction ■ Measurement Example 1: Starch ■ Measurement Example 2: Active Ingredients ■ Summary ■ CAMSIZER X2: Features *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of wood fibers and wood powder. Wood fibers are 100% renewable organic materials used in various applications such as building materials, animal bedding pellets, and biomass for energy generation. The size and shape of the particles are important not only for the homogeneity and strength of particle boards but also when gasifying wood for use as biofuel in engines. For this biofuel, the surface area of the ground material significantly affects the pyrolysis process. 【Contents】 ■ Applications ■ Quality control requirements and limitations of sieving ■ Measurement example 1: Particle size measurement of wood fibers ■ Measurement example 2: Particle size distribution of sawdust ■ Features of CAMSIZER X2 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe document introduces the particle size distribution of solder powder and metal powder. The particle size distribution of metal powder varies from a few micrometers to millimeters depending on the application, with most falling between 10 micrometers and 100 micrometers. Various processes, such as grinding and different spraying processes, are used in the production of metal powder. A common method to obtain the desired particle size distribution is to "sieve" the metal powder with a wide particle size distribution during the manufacturing stage. [Contents (excerpt)] ■ Applications ■ Quality control and research and development of metal powder ■ Measurement of solder powder using CAMSIZER X2 ■ Measurement example 1: Particle size distribution measurement of solder powder using CAMSIZER X2 ■ Measurement example 2: Measurement reproducibility of CAMSIZER X2 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of food (powder and granules). Food particles often agglomerate and may have oil content or stickiness, making proper particle dispersion a significant challenge. Air jet sieving and laser diffraction/scattering are commonly used measurement techniques, but there may be cases where measurement resolution, manpower, and sensitivity are insufficient. The 'CAMSIZER X2' is suitable for rapidly and accurately analyzing the particle size distribution and particle shape of crystalline, powdered, and granular foods. [Contents] ■ Applications ■ Example 1: Ground coffee beans ■ Example 2: Baby food (powdered milk, milk substitutes) ■ Measurement principle of CAMSIZER X2 ■ Features of CAMSIZER X2 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution of carbon. Carbon components are used in applications where high heat resistance and chemical resistance are required. The 'CAMSIZER X2' is suitable for measuring the particle size distribution and particle shape of graphite, powdered or crushed coal and coke, activated carbon, and even industrial diamonds used as abrasives. [Contents] ■ Applications ■ Measurement of various carbons ■ Dynamic image analysis CAMSIZER X2 ■ Example of measurement of carbon brush raw materials ■ Features of CAMSIZER X2 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (granulometry) and particle shape of proppants. The role of proppants contained in fracturing fluids is to keep the cracks in the rock open and maintain the permeability of oil and gas. Proppants include sand, resin-coated sand, and ceramic beads, and to achieve good permeability, the particle size must match the size of the cracks, and the particle size distribution must be narrow. [Contents] ■ Applications ■ Quality control of proppants ■ Dynamic image analysis CAMSIZER P4 ■ Features of CAMSIZER P4 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe document introduces the particle size distribution and particle shape of activated carbon. Activated carbon is used as a filter material to adsorb gases, bacteria, odors, and more in various industrial fields. The characteristics of the filter are greatly influenced by the particle shape and particle size distribution of the activated carbon. The 'CAMSIZER P4' provides reliable information on both aspects and is suitable for quality control and production management. [Contents (excerpt)] ■ Applications ■ Dynamic image analysis CAMSIZER P4 ■ Measurement of fine particles in activated carbon ■ Reproducibility ■ Data consistency with sieving *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of petroleum coke. Controlling the grinding state of petroleum coke, which is the raw material for electrodes, is particularly important because both the particle size distribution and particle shape of the ground material significantly affect the quality of the product. The dynamic image analysis device 'CAMSIZER P4' is well-suited for evaluating the particle size distribution and particle shape of petroleum coke. [Contents] ■ Applications ■ Solutions: CAMSIZER P4 ■ Screening and high data consistency ■ Measurement of particle size distribution and particle shape ■ Features of CAMSIZER P4 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces the particle size distribution (particle diameter distribution) and particle shape of fertilizers. Fertilizers and fertilizer granules need to have a particle size distribution suitable for their purpose in order to ensure a certain dilution time and control the release of nutrients. The 'CAMSIZER P4' dynamic image analysis device is a powerful alternative that offers higher accuracy and reproducibility, as well as the ability to process more samples. Automated measurements ensure that the results are not dependent on the operator, allowing even untrained individuals to perform high-precision measurements. [Contents] ■ Applications ■ CAMSIZER P4 suitable for fertilizer measurement ■ Particle size distribution of fertilizers ■ Particle shape of fertilizers ■ Features of CAMSIZER P4 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "BELPYCNO L" is a fully automatic true density measurement device (multi-volume specification) capable of measuring the volume and true density (skeleton density) of various powders, granular materials, porous materials, molded bodies, mixtures, pastes, and liquids. With automatic temperature control and pressure sensors, it is possible to minimize the impact of fluctuations in ambient temperature and pressure on density. By combining three types of expansion cells (volumes of 20, 40, and 60 cm³), true density evaluation of samples ranging from small to large volumes (4, 20, 40, 60, 100, and 135 cm³) can be performed. 【Features】 ■ Built-in high-precision pressure sensor (absolute pressure gauge) ■ Measurement possible with separation of the cell section (sample chamber and expansion chamber) and the operation panel section ■ Built-in high-precision ATC (automatic temperature control) ■ Short measurement time with high stability ■ High reproducibility *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document is a collection of data from "CAMSIZER," which introduces the world of micrometers that can be understood through dynamic image analysis. It includes particle size distribution and particle shape analysis using dynamic image analysis for samples of spherical particles (mixed particle resolution), as well as food and industrial materials. The information is summarized clearly using tables and figures, so please take a moment to read it. 【Contents (excerpt)】 ■ MRB product lineup (particle size distribution, particle shape) ■ Dynamic image analysis CAMSIZER X2 ■ Selecting a suitable feeder for CAMSIZER X2 samples ■ Glass bead mixed particles_CAMSIZER X2_wet measurement ■ Carbon fiber_CAMSIZER X2_wet measurement *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document is a collection of data from "CAMSIZER," which introduces the world of micrometers that can be understood through static image analysis. It includes analyses of particle size distribution and particle shape using static image analysis for spherical particles (mixed particle resolution), as well as non-spherical particles (with a wide particle size distribution) and samples of industrial materials and applications. The information is summarized clearly using tables and figures, so please take a moment to read it. [Contents] ■ MTB Product Lineup (Particle Size Distribution) ■ CAMSIZER M1 ■ Static Image Analysis CAMSIZER M1 ■ Measurement of Polystyrene Latex Mixed Particles ■ Measurement Images of Polystyrene Latex *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document is a collection of data from "CAMSIZER," which introduces the world of millimeters through images. It includes applications related to fertilizers, food, and building materials, as well as evaluations of particle size distribution and shape indices using dynamic image analysis methods. The information is summarized clearly using tables and figures, so please take a moment to read it. 【Contents (excerpt)】 ■ Fertilizers (large particles) ■ Fertilizers (small particles) ■ Comparison of fertilizers (particle size distribution and shape) ■ Fertilizers (pellets) ■ Sugar (medium granulated sugar) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CAMSIZER X2" is a powerful and versatile particle characterization device that combines new camera technology with flexible sample dispersion options. Based on the principle of dynamic image analysis (ISO 13322-2), it accurately determines particle size and shape for powders, granules, and suspensions over a wide measurement range of 0.8μm to 8mm. It generates a flow of particles in either dry powder or suspension state, continuously capturing particle images at a frame rate of 300 images per second using a high-brightness strobe light source and two high-resolution digital cameras. 【Features】 ■ Captures hundreds of thousands to millions of particle images in a short measurement time of 1 to 3 minutes ■ Enables comprehensive and reliable characterization of samples ■ Complies with ISO 13322-2 dynamic image analysis ■ Utilizes unique dual-camera technology to accommodate a wide measurement range (0.8μm to 8mm) ■ High-resolution measurements for sharp particle size distributions and multiple peak distributions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CAMSIZER X2" is a powerful and versatile particle characterization device that combines new camera technology with flexible sample dispersion options. Based on the principle of dynamic image analysis (ISO 13322-2), it accurately determines particle size and shape for powders, granules, and suspensions over a wide measurement range of 0.8μm to 8mm. It generates a flow of particles in either dry powder or suspension state and continuously captures particle images at a frame rate of 300 images per second using a high-intensity strobe light source and two high-resolution digital cameras. 【Features】 ■ Captures hundreds of thousands to millions of particle images in a short measurement time of 1 to 3 minutes ■ Enables comprehensive and reliable characterization of samples ■ Complies with ISO 13322-2 dynamic image analysis ■ Utilizes unique dual camera technology to accommodate a wide measurement range (0.8μm to 8mm) ■ Provides sharp particle size distributions and high-resolution measurements in multi-peak distributions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CAMSIZER X2" is a powerful and versatile particle characterization device that combines new camera technology with flexible sample dispersion options. Based on the principle of dynamic image analysis (ISO 13322-2), it accurately determines particle size and shape for powders, granules, and suspensions across a wide measurement range of 0.8μm to 8mm. It generates particle flow in a dry powder or suspension state, continuously capturing particle images at a frame rate of 300 images per second using a high-intensity strobe light source and two high-resolution digital cameras. 【Features】 ■ Captures hundreds of thousands to millions of particle images in a short measurement time of 1 to 3 minutes ■ Enables comprehensive and reliable characterization of samples ■ Complies with ISO 13322-2 dynamic image analysis ■ Utilizes unique dual camera technology to accommodate a wide measurement range (0.8μm to 8mm) ■ High-resolution measurements of sharp particle size distribution (granulometric distribution) and multi-peak distributions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CAMSIZER X2" is a powerful and versatile particle characterization device that combines new camera technology with flexible sample dispersion options. Based on the principle of dynamic image analysis (ISO 13322-2), it accurately determines particle size and shape for powders, granules, and suspensions over a wide measurement range of 0.8μm to 8mm. It generates a flow of particles in a dry powder or suspension state, continuously capturing particle images at a frame rate of 300 images per second using a high-intensity strobe light source and two high-resolution digital cameras. 【Features】 - Captures hundreds of thousands to millions of particle images in a short measurement time of 1 to 3 minutes - Enables comprehensive and reliable characterization of samples - Complies with ISO 13322-2 dynamic image analysis - Utilizes unique dual camera technology to accommodate a wide measurement range (0.8μm to 8mm) - High-resolution measurements for sharp particle size distributions and multiple peak distributions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CAMSIZER X2" is a powerful and versatile particle characterization device that combines new camera technology with flexible sample dispersion options. Based on the principle of dynamic image analysis (ISO 13322-2), it accurately determines particle size and shape for powders, granules, and suspensions over a wide measurement range of 0.8μm to 8mm. It generates a flow of particles in a dry powder or suspension state and continuously captures particle images at a frame rate of 300 images per second using a high-brightness strobe light source and two high-resolution digital cameras. 【Features】 ■ Captures hundreds of thousands to millions of particle images in a short measurement time of 1 to 3 minutes ■ Enables comprehensive and reliable characterization of samples ■ Complies with ISO 13322-2 dynamic image analysis ■ Utilizes unique dual camera technology to accommodate a wide measurement range (0.8μm to 8mm) ■ High-resolution measurements of sharp particle size distributions (granulometric distributions) and multiple peak distributions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm, Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single unit ■ The three-laser system has become a standard evaluation device in various industries for measuring particle size distribution ■ Capable of evaluating over 30 shape parameters including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 - Measurement range: Particle diameter: 0.02 to 2000 μm, Image analysis: 5 to 2000 μm - Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device - The three-laser system has become a standard evaluation device in various industries for measuring particle size distribution - Capable of evaluating over 30 shape characteristics, including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles ranging from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm; Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single unit ■ The three-laser system has become a standard evaluation device in various industries for particle size distribution measurement ■ Capable of evaluating over 30 shape characteristics, including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles ranging from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm; Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device ■ The three-laser system has become a standard evaluation device in various industries for measuring particle size distribution ■ Capable of evaluating over 30 shape parameters, including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-beam laser optical system, it detects scattered light from particles at high angles of 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm, Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single unit ■ The three-beam laser system has become a standard evaluation device in various industries for measuring particle size distribution ■ Capable of evaluating over 30 shape parameters including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm, Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device ■ The three-laser system for particle size distribution measurement has become a standard evaluation device in various industries ■ Capable of evaluating over 30 shape parameters including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, roughness, etc. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles of 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circle diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm; Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single unit ■ The three-laser system has become a standard evaluation device in various industries for measuring particle size distribution ■ Capable of evaluating over 30 shape parameters, including equivalent circle diameter, equivalent ellipse diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYNC is a particle size distribution and shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It allows for the evaluation of roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm; Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device ■ A standard evaluation device in various industries, utilizing a three-laser system for particle size distribution measurement ■ Capable of evaluating over 30 shape parameters including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"SYNCH" is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles of 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circle diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm, Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device ■ Particle size distribution measurement using a three-laser system, which has become a standard evaluation device in various industries ■ Capable of evaluating over 30 shape characteristics, including equivalent circle diameter, equivalent ellipse diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"SYNCH" is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles ranging from 0 to 165 degrees, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm; Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device ■ Particle size distribution measurement using a three-laser system, which has become a standard evaluation device in various industries ■ Capable of evaluating over 30 shape parameters, including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe are pleased to announce that until the campaign period (2021/05/23), you can download "Data Collection CAMSIZER PART III 'The World of Micrometers Revealed by Dynamic Image Analysis'"! Please take a look. By accurately measuring the "particle size distribution" and "particle shape" of ceramic particles, we optimize their processing characteristics, flowability, compressibility, and transport properties. Evaluating the basic properties of ceramic raw materials (such as particle size distribution, particle shape, and specific surface area) is essential as it significantly impacts the performance of the processed products. In particular, there is a growing demand for efficient evaluation of particle size distribution and particle shape. 【Features】 ■ The two-camera optical system enables a wide measurement range without the need for lens switching or adjustments, achieving high-precision measurements. ■ Dry measurement: Particles are dispersed and measured using natural fall from an electromagnetic feeder or compressed air. ■ Wet measurement: Compatible with aqueous/organic solvent systems. Evaluates the long diameter, short diameter, and aspect ratio of fibrous particles. ■ The CAMSIZER offers high data consistency with measurements obtained through sieving. Please feel free to contact us. Material gift campaign period: until 2021/05/23.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"SYNC" is a particle size distribution and particle shape measurement device that achieves high-precision particle size distribution measurement and shape evaluation through image analysis in a single unit. With a three-laser optical system, it detects scattered light from particles at high angles ranging from 0 to 165 degrees as a continuous surface, enabling high-resolution measurement of particle size distribution. It is capable of evaluating roundness, aspect ratio, roughness, equivalent circular diameter, short and long axes of ellipses, Feret diameter, and more. 【Features】 ■ Measurement range: Particle diameter: 0.02 to 2000 μm, Image analysis: 5 to 2000 μm ■ Achieves high-precision particle size distribution and shape evaluation through image analysis in a single device ■ Particle size distribution measurement using a three-laser system, which has become a standard evaluation device in various industries ■ Capable of evaluating over 30 shape characteristics, including equivalent circular diameter, equivalent elliptical diameter (short and long axes), Feret diameter (short and long axes), roundness, aspect ratio, and roughness *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"BELCRYO" is a low-temperature variable temperature control unit that can perform automatic measurements in conjunction with an adsorption device. It can control temperatures from 50K to extremely low temperatures and is capable of high-pressure measurements of over 10MPa. Gas adsorption measurements can be conducted at any temperature that could not be controlled with refrigerants, eliminating the need for refrigerants like liquid oxygen and removing restrictions on measurement time. [Features] ■ Temperature control is possible from 50K to 473K ■ Gas adsorption measurements can be conducted at any temperature that could not be controlled with refrigerants ■ No need for refrigerants like liquid oxygen, and there are no restrictions on measurement time ■ Fully automatic in-situ measurements from pretreatment to measurement in conjunction with measurement software ■ Supports high-pressure measurements of over 10MPa *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "BELSORP MAX G" is a dedicated device for evaluating porous and non-porous materials (BET specific surface area and pore distribution) and gas adsorption capacity. A compact and low-cost model has been newly added to the lineup of BELSORP MAX, which can evaluate from micropores. It can be widely used in catalysts, batteries (solid-state batteries, fuel cells, etc.), fibers, polymer materials, chemicals, pigments, cosmetics, and more. 【Features】 ■ Evaluation of BET specific surface area and a wide range of pore distribution from micropores through ultra-low pressure measurements of N2 (77.4K) and Ar (87.3K) ■ Evaluation of low specific surface area through gas adsorption measurements with Kr (77.4K) ■ Advanced analysis using BELMaster Ver.7 equipped with new pore distribution theories such as GCMC and NLDFT ■ Gas introduction optimization (GDO) function ensures reliable evaluation of each adsorption point in a short time *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "BELSORP MAXII-HP" is a high-precision gas/vapor adsorption measurement device capable of evaluating material properties (BET specific surface area and pore distribution) as well as gas and vapor separation performance. A new high-pressure gas adsorption measurement specification has been added to the BELSORP MAXII lineup. In addition to evaluating the BET, pore distribution, and vapor adsorption of materials, it is now possible to evaluate the adsorption of various gases under high pressure. 【Features】 ■ Capable of evaluating the adsorption of various high-pressure gases (up to 900 kPa) at temperatures up to 70°C ■ Accurate adsorption evaluation achieved through automatic calculation of the compressibility factor, taking into account the non-ideality of various adsorbate gases ■ The analysis software BELMaster Ver. 7 allows for not only BET and pore distribution analysis but also adsorption rate evaluation *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration