Water treatment equipment Product List and Ranking from 43 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

Water treatment equipment Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. サンエー工業 Tokyo//Facility Design Office
  2. 富士計器 本社 Hokkaido//Electricity, Gas and Water Industry
  3. ヴァンテック Tokyo//Building materials, supplies and fixtures manufacturers
  4. 流機エンジニアリング 本社 Tokyo//Building Management
  5. 5 エコサイクル Tokyo//Building Management

Water treatment equipment Product ranking

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. Vantech Pipe Comprehensive Catalog ヴァンテック
  2. Multi-pole magnetic field far-infrared water treatment device "Thunder System" 富士計器 本社
  3. Coagulation Aid "Aqua Lite" エコサイクル
  4. 4 High-precision adsorption water treatment device effective against PFAS: ECO Clean LFP 流機エンジニアリング 本社
  5. 5 Reference material on the relationship between surface area load and thickener capacity in wastewater treatment. サンエー工業

Water treatment equipment Product List

226~240 item / All 438 items

Displayed results

Case study of the magnetic water activation device "Muzatsu" - Fukuoka City Apartment G

Scale removal in 3 years! Obstruction rate reduced from 51.2% to 0%! Also prevents adhesion.

"Muza" is a magnetic water treatment device that solves the 3S problems of water (scale: limescale, slime: bacteria, rust: red water) and algae issues with the industry's best magnetic field (circulating water 10,000G, once-through water 15,000G). This page introduces a case study of the installation in Mansion G located in Fukuoka City. In Mansion G, regular maintenance is performed, and approximately three years since the last maintenance, the following effects have been observed: ■ Condition of the water pipes  ◯ Blockage rate reduced from 51.2% to 0%  ◯ Removal of scale (limescale) and slime (bacteria) confirmed  ◯ Prevention of attachment confirmed ■ Condition of "Muza"  ◯ No deformation or corrosion observed in the unit, mag case, or magnets ◎ By downloading the catalog, you can view the regular maintenance document (details of the above content) in PDF format.

  • Sanitary fixtures

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Magnetic Water Treatment Device 'Muzatsu' Case Study (Apartment Water Supply Pipe)

We will introduce examples of how "Muzou-zatsu" solves the problems of scale, rust, and slime that occur in water supply pipes and other systems.

The "Muzatsu" magnetic water treatment device utilizes the electromagnetic induction phenomenon to prevent blockages, corrosion, energy loss, and chemical loss caused by the "3S problems" of water, namely "scale," "rust," and "slime (algae)." In this case study, we present examples of how "Muzatsu" has provided solutions, accompanied by photos and easy-to-understand explanations. The design, which allows water to come into direct contact with a super-strong magnetic field and a flow rate above a certain level, produces clear effects and resolves issues with condominium water pipes. We confidently recommend you try "Muzatsu." For more details, please contact us or download the catalog.

  • Sanitary fixtures

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【No Mixed Usage Examples】Existing Water Supply Pipe

Effective rehabilitation of water supply pipes! We will introduce a case study that achieved long lifespan by removing water stains, red rust, and bacteria through "no-mix" installation.

We would like to introduce a case study using "Muzatsu," handled by Toko Co., Ltd. After 15 years of installation, the existing water supply pipe has a blockage rate of 50%. The water supply pipe is definitely heading towards blockage. By installing "Muzatsu," we effectively removed scale, rust, and bacteria, achieving rehabilitation of the water supply pipe and extending its lifespan. Additionally, there are cases of removing algae that breed in the fin section of cooling towers and resolving red water without using chemicals. 【Muzatsu After 10 Years】 ■ Blockage Rate 0% ■ Scale Removal ■ No Bacteria ■ No Red Water *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Magnetic Water Treatment Device 'Muzatsu' <Case Study Presentation>

A proposal for cooling tower managers who are fighting with long-term chemical input.

To the engineers who have been fighting for a long time with the long-term, economic, and management operations of cooling towers, are you still forced to use chemical treatments? Regarding the issues of scale, slime, rust, and algae, which are essential for the operation of cooling towers, I speculate that the current specific measures are primarily chemical treatments or maintenance through manpower. Therefore, we have a proposal from Toko. The measures for the 3S problems of scale, slime, and rust in water have already been completed. An effective countermeasure is the utilization of water. This is a strategy based on understanding water pressure, flow, and volume, and there is no risk of failure. Cooling tower engineers, please consider this low-risk, high-return strategy. There will be no charge if results are not achieved. You can use it with confidence. *You can view materials with case studies from the "PDF Download." Please feel free to contact us.

  • Water Treatment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

"Scale Adhesion Prevention" Electromagnetic Water Treatment Device 'Hydroflow' *Made in the UK

Maintenance-free! Water treatment device for corrosion prevention, scale adhesion prevention, red rust measures, algae control, and slime prevention.

The electromagnetic water treatment device "Hydroflow" is a device that treats water by forming an electromagnetic field inside various types of pipes. By applying the principle of a transformer, it induces a magnetic field and electric field perpendicular to the water flow inside the pipe through a ferrite ring wrapped around the outside of the pipe, which is simply attached to the outside of the piping. This effect is propagated through the water, acting on scale and other issues up to 5000 meters upstream and downstream. 【Features】 ■ Prevents scale adhesion and addresses rust without chemicals ■ Applicable to all pipe materials without the need for piping work ■ Contributes to the longevity of the entire system ■ Maintenance-free, with running costs equivalent to just the electricity of 1-2 fluorescent lights *For more details, please download the catalog or contact us.

  • Water Treatment Plant

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Aluminum die-casting mold cooling [Electromagnetic water treatment device Vol. 4]

Introduction of a case study on preventing cooling scale in aluminum die-casting molds through hydroflow installation.

We will introduce a case study on preventing cooling scale in the aluminum die-casting mold of the "Hydroflow Electromagnetic Water Treatment Device." The user is ED Industry Co., Ltd. (an aluminum die-casting manufacturer in Shizuoka Prefecture). The silica content in the well water is high at 48 mg/L, and when scaling occurs, it forms a very hard scale, leading to a significant decrease in production efficiency. To prevent the occurrence of defective products, the device was installed. The equipment used includes five aluminum die-casting machines and an oil cooler. 【Installation and Effect Confirmation】 ■ Installed Model: Electromagnetic Water Treatment Device "Hydroflow," Model: P60 × 1 unit ■ Usage Period: From July 14, 2011, to November 21, 2011, for four months ■ Regular checks on the scale adhesion condition of the jet cooler pipes - Before treatment: Replaced after approximately 25,000 to 35,000 shots - After treatment: Extended to 90,000 to 95,000 shots ⇒ Significantly contributed to efficiency improvement For more details, please refer to the catalog or feel free to contact us.

  • Water Treatment Plant

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Countermeasures for Red Water in Business Hotels [Electromagnetic Water Treatment Device Vol. 3]

Install this device on the return pipe of the circulating water to the storage tank! Conducted to check the feasibility of corrosion prevention while operating normally.

We would like to introduce a technical case of installing the electromagnetic water treatment device "Hydroflow" at a certain business hotel in Saitama Prefecture. The hotel's plumbing consists of heat-resistant PVC lined pipes, and the hot water storage tank is made of steel with anti-rust paint. However, since it has been 17 years since its construction, repainting the anti-rust coating would require the hotel to close temporarily. In this case, we installed the device on the return pipe of the circulating water to the hot water storage tank and conducted the installation while the hotel was in normal operation to verify whether corrosion prevention could be achieved. As a result, we successfully addressed the issue of red water in the hot water supply within about one month. 【Case Overview】 ■ Test Period: December 6, 2011 - January 10, 2012 ■ Location: A certain business hotel in Saitama Prefecture ■ Target Device - British-made electromagnetic water treatment device Hydroflow - Model: P100 (for 65A and 80A) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Spring Water Scale Countermeasures [Electromagnetic Water Treatment Device Vol. 6]

We will introduce a case of installation on a submerged pump that had stopped due to calcium scale.

We would like to introduce a technical case study of the electromagnetic water treatment device "Hydroflow." The water from the spring pit located 15 meters underground at the power plant is supplied through pipes A and B, but it is extremely hard water. The submersible pump for drainage stops due to calcium scaling in about three months, requiring the replacement of the pump each time, which incurs significant costs and time, causing difficulties. Therefore, we installed the Hydroflow model S100 on the water lift pipe. The effective range of this device is approximately 5,000 meters before and after the installation location. This device is a semiconductor product that requires no installation costs or maintenance, and it has been operating smoothly for two years since installation. [Case Overview] ■ Challenges - The pump stops due to calcium scaling in about three months because of hard water. - Replacing the pump each time incurs significant costs and time. ■ Results - It has been operating smoothly for two years since installation. *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment Plant

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Solution for hard water scale in the use of bore water in Australia.

A case study of successfully preventing scale adhesion using polar utilization. We will introduce the situation before and after treatment with photos!

Here is an example of solving hard water scale issues in the use of well water in Australia. We successfully prevented scale buildup on the fins and pipes of spray cooling water using polar treatment. We have included photos showing the significant scale presence before polar treatment and the absence of scale afterward. For more details, please check the PDF download below. [Measures and Effects] ■ Successfully prevented scale buildup on the fins and pipes of spray cooling water using polar treatment. *For more information, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study on Corrosion Prevention Effects of Chilled Water in Air Conditioning Systems [Magnetic Water Treatment Device Vol. 6]

Installed on the supply header outlet side! An example showing a dark brown color compared to the untreated side.

There are two comparison devices for the internal pipe inspection; one utilizes a polarizer, while the other does not. A comparative inspection was conducted under conditions where the polarizer was not used. One polarizer model "PI-50F (2”)” was installed on the discharge side of the supply header for cold and hot water, with partial circulation treatment performed using the polarizer. After treatment, it was evident that old scale and rust had dissolved and flowed out, forming a magnetite anti-corrosion coating inside the pipe, which appeared smoother and had a dark brown color compared to the untreated side. The untreated side showed signs of corrosion and scale adhesion. [Case Study] ■ Installation Date: December 1985 ■ Purpose: Anti-corrosion and anti-scaling for cold and hot water equipment ■ Installation Method: Installed the polarizer model "PI-50F (50A)" on the outlet side of the supply header ■ Treated Water Volume: Treated more than 5% of the total circulating water volume *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Cooling Water (Chiller Water) Molding Machine Mold Case Study [Magnetic Water Treatment Device Vol. 2]

Cooling water volume increased by 16%! Red rust has been completely removed and changed to black rust.

Tests were conducted in the cooling passages of plastic molds with the aim of removing blockages caused by rust and scale using a polarizer, thereby restoring cooling effectiveness. Additionally, we confirmed whether the removal of red rust from the cooling passages and its reduction to black rust (magnetite) would lead to the formation of an anti-corrosion coating. As a result, when the rust that had dissolved into the water tank was collected and a magnet was applied, the rust was attracted to the magnet, indicating that it had transformed into magnetite. [Test Details] ■ Purpose - To remove blockages caused by rust and scale in the cooling passages of plastic molds using a polarizer, thereby restoring cooling effectiveness (increasing cooling water flow rate). - To confirm whether the removal of red rust from the cooling passages and its reduction to black rust would lead to the formation of an anti-corrosion coating. ■ Location: SK Corporation Headquarters (Gifu Prefecture) ■ Duration: January 21, 1992 - May 30, 1992 (24-hour continuous bench test operation) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Countermeasures (Hot Water Supply of Large Hospitals) [Magnetic Water Treatment Device Vol. 11]

This is an introduction to a case where water quality improvement was achieved through the effects of a polar magnetic water treatment device!

This is a case study of measures taken against red water in a certain hospital in Okayama City (approximately 15 years after construction). A "PI-25F" Polar unit was installed on the pump discharge side, treating more than 50% of the circulating water in a partial bypass method, with water samples taken from the hospital faucet every morning at 10 AM. Sixty days after installation, improvements in water quality were observed in all aspects, including general bacteria, iron content, odor, taste, color, and turbidity, due to the effectiveness of the Polar magnetic water treatment device, particularly confirming its effectiveness in addressing red water issues in hot water supply. [Case Study] ■ Client: A certain hospital in Okayama City (approximately 15 years after construction) ■ Installation Date: Installed on March 7, 1987 ■ Water Quality Analysis Location: Okayama Medical Laboratory Center Co., Ltd. ■ Sampling Method: Water samples taken from the hospital faucet every morning at 10 AM ■ Polar Installation Method: A "PI-25F" Polar unit was installed on the pump discharge side, treating more than 50% of the circulating water in a partial bypass method. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

About the cause of red water (300 households) [Magnetic water treatment device Vol. 2]

We will introduce examples of conducting water main extraction in various housing complexes and investigating corrosion within the pipes!

Since the 1970s, as a measure against red water in buildings constructed after that period, the Ministry of Construction has guided the increased use of PVC-lined pipes over white gas pipes (galvanized steel pipes). Furthermore, from the 1980s to the present day (2002), many buildings, apartments, and general residences have experienced occurrences of red water every morning. As a result, in various housing complexes, investigations were conducted on the corrosion of the water supply pipes by removing them. The findings revealed that most of the corrosion inside the pipes was caused by the potential difference between dissimilar metals at the valves and pipe joints, as well as damage to the PVC lining seals. It was determined that the dissolved oxygen in the water reacts electrochemically with the metals through the water. [Causes] ■ Most of the corrosion inside the pipes is due to the potential difference between dissimilar metals at the valves and pipe joints, and damage to the PVC lining seals. ■ The dissolved oxygen in the water reacts electrochemically with the metals through the water. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Countermeasures (Hotel Hot Water Supply) [Magnetic Water Treatment Device Vol. 9]

Installed with a partial bypass method on return pipe 65A! Introduction of a case where red rust in the boiler turned into black rust and red water stopped.

There was a complaint that red water was coming out of the hot water faucet in the guest rooms within three years of the hotel's completion, and various measures were taken, but the issue was not resolved at all. As a result, a Polar magnetic water treatment device "Model PI-25F" (3-point set) was installed in a partial bypass configuration on the return pipe 65A, treating about 20% of the circulating water volume. As a result, it was confirmed that the red rust in the boiler had turned into black rust, and the red water had stopped. [Case Study] ■ Issues - Despite the piping being made of stainless steel and plastic, red water occurred. - The cause of the red water was corrosion due to an abnormal oxidation reaction of dissolved oxygen (DO) in the water inside the steel hot water heater. ■ Measures - A Polar magnetic water treatment device "Model PI-25F" (3-point set) was installed in a partial bypass configuration on the return pipe 65A. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion and scale prevention for chilled water in air conditioning systems [Magnetic Water Treatment Device Vol. 7]

The water quality in the pipe is slightly alkaline! The pH has increased, there is less iron, the water is clear, and the corrosion resistance is significant.

This introduces the corrosion prevention, scale prevention, and water quality purification effects of chilled and warm water systems. To confirm the effectiveness of the newly installed chilled and warm water pipes, an internal surface inspection was conducted. A very thin, dense, and uniform white (inorganic) corrosion-resistant film was formed, and there was no occurrence of rust. The water quality inside the pipes was slightly alkaline, and the iron content was within the drinking water standards. The clips in the sample water also did not rust, resulting in excellent outcomes. [Case Study] - Installation Location: A certain hospital in Fukuoka Prefecture - Installation Date: February 16, 1999 - Polar Model: PI-50F x 2 units - Installation Location: Chilled and warm water equipment for air conditioning (2 units) - Installation Method: Partial (5%) back method *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Search Keywords Related to Water treatment equipment