Inspection of equipment corrosion, thinning, and cracking! Evaluation of remaining life and integrity 'Static Equipment Diagnosis'
Over 40 years, approximately 5,000 inspections have been conducted on equipment both within and outside the Toray Group! By inspecting for corrosion, thinning, and cracking of equipment, we evaluate the integrity of the facilities.
In "Static Equipment Diagnosis," we evaluate the corrosion and deterioration of various equipment such as towers, heat exchangers, and piping, allowing us to identify risks of leakage and damage, as well as assess remaining lifespan. Not only do we provide measurement data, but we also offer cause estimation and recommendations for countermeasures based on our extensive knowledge gained from damage analysis and other sources. For long-distance piping where full-length inspection is difficult, we conduct economic evaluations using extreme value analysis, responding flexibly to customer requests. ■ Various non-destructive testing methods such as penetrant testing, ultrasonic testing, and magnetic particle testing ■ Inspection of confined spaces using industrial endoscopes and 360-degree cameras ■ Observation of metal microstructures using the sump method ■ Evaluation of FRP tank deterioration (jointly developed evaluation criteria with Toray) Others.
- Company:東レエンジニアリング中部
- Price:Other