iPROS Urban Planning
  • Search for products by classification category

    • Building Materials
      Building Materials
      35537items
    • Facilities
      Facilities
      56659items
    • Lighting and Interior
      Lighting and Interior
      17273items
    • Common materials
      Common materials
      37011items
    • Civil Engineering Materials
      Civil Engineering Materials
      9533items
    • Construction, work and methods
      Construction, work and methods
      27653items
    • Surveys, Measurements, and Services
      Surveys, Measurements, and Services
      30352items
    • IT/Software
      IT/Software
      31856items
    • others
      others
      84579items
    • Store and facility supplies
      Store and facility supplies
      4358items
    • Office and commercial supplies
      Office and commercial supplies
      11463items
    • Hospital and welfare facility supplies
      Hospital and welfare facility supplies
      952items
    • Logistics Equipment
      Logistics Equipment
      7378items
    • Energy and Resources
      Energy and Resources
      11606items
  • Search for companies by industry

    • Information and Communications
      7198
    • others
      6980
    • Building materials, supplies and fixtures manufacturers
      6683
    • Service Industry
      4607
    • Trading company/Wholesale
      2996
    • Other construction industries
      2455
    • Electrical equipment construction business
      642
    • Interior Design
      528
    • Facility Design Office
      492
    • Construction Consultant
      464
    • Architectural design office
      361
    • retail
      345
    • Warehousing and transport related industries
      321
    • Electricity, Gas and Water Industry
      290
    • General contractors and subcontractors
      288
    • Interior construction business
      274
    • Medical and Welfare
      272
    • Educational and Research Institutions
      258
    • Building Management
      253
    • Renovation and home construction industry
      224
    • Water supply and drainage construction business
      204
    • Housing manufacturers and construction companies
      187
    • Transportation
      160
    • Real Estate Developers
      155
    • Fisheries, Agriculture and Forestry
      124
    • Structural Design Office
      66
    • Finance, securities and insurance
      35
    • Restaurants and accommodations
      29
    • self-employed
      29
    • Mining
      26
    • Public interest/special/independent administrative agency
      18
    • Police, Fire Department, Self-Defense Forces
      18
    • Store and building owners
      9
    • Property Owner
      8
    • Government
      8
    • Individual
      8
  • Special Features
  • Ranking

    • Overall Products Ranking
    • Overall Company Ranking
Search for Products
  • Search for products by classification category

  • Building Materials
  • Facilities
  • Lighting and Interior
  • Common materials
  • Civil Engineering Materials
  • Construction, work and methods
  • Surveys, Measurements, and Services
  • IT/Software
  • others
  • Store and facility supplies
  • Office and commercial supplies
  • Hospital and welfare facility supplies
  • Logistics Equipment
  • Energy and Resources
Search for Companies
  • Search for companies by industry

  • Information and Communications
  • others
  • Building materials, supplies and fixtures manufacturers
  • Service Industry
  • Trading company/Wholesale
  • Other construction industries
  • Electrical equipment construction business
  • Interior Design
  • Facility Design Office
  • Construction Consultant
  • Architectural design office
  • retail
  • Warehousing and transport related industries
  • Electricity, Gas and Water Industry
  • General contractors and subcontractors
  • Interior construction business
  • Medical and Welfare
  • Educational and Research Institutions
  • Building Management
  • Renovation and home construction industry
  • Water supply and drainage construction business
  • Housing manufacturers and construction companies
  • Transportation
  • Real Estate Developers
  • Fisheries, Agriculture and Forestry
  • Structural Design Office
  • Finance, securities and insurance
  • Restaurants and accommodations
  • self-employed
  • Mining
  • Public interest/special/independent administrative agency
  • Police, Fire Department, Self-Defense Forces
  • Store and building owners
  • Property Owner
  • Government
  • Individual
Special Features
Ranking
  • Overall Products Ranking
  • Overall Company Ranking
  • privacy policy
  • terms of service
  • About Us
  • Careers
  • Advertising
  1. Home
  2. Building materials, supplies and fixtures manufacturers
  3. ビカ・ジャパン
  4. Product/Service List
Building materials, supplies and fixtures manufacturers
  • Added to bookmarks

    Bookmarks list

    Bookmark has been removed

    Bookmarks list

    You can't add any more bookmarks

    By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

    Free membership registration

ビカ・ジャパン

EstablishmentApril 1, 1999
capital8000Ten thousand
number of employees40
addressTokyo/Minato-ku/6th Floor, MG Shibaura Building, 1-8-4 Shibaura
phone03-5439-6673
  • Official site
last updated:Nov 12, 2024
ビカ・ジャパンlogo
  • Contact this company

    Contact Us Online
  • Company information
  • Products/Services(652)
  • catalog(300)
  • news(31)

ビカ・ジャパン List of Products and Services

  • category

316~360 item / All 652 items

Displayed results

class="retina-image"

Clamp connection inline diaphragm seal for pharmaceuticals and food applications.

Clamp connection inline diaphragm seal. It has no dead space and is ideal for clean services, pharmaceuticals, food, SIP, and CIP applications.

Clamp connection inline diaphragm seal. It has no dead space and is ideal for clean services, pharmaceuticals, food, SIP, and CIP applications. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified - Connection standards: DIN32676 ISO2852 - Material: SUS316L, Hastelloy - 3-A, EHEDG certified - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. Please refer to the product data sheet for more details.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary Clamp Connection Inline Diaphragm Seal

Inline diaphragm seal with clamp connection. It has no dead space and is ideal for clean services, pharmaceuticals, food, SIP, and CIP applications.

Inline diaphragm seals can be used in applications that involve media that are difficult to measure with standard diaphragm structures. We offer a variety of designs, materials, and filling liquids, making them particularly suitable for pharmaceutical and food-related applications. They can withstand the cleaning steam temperatures generated during SIP processes and ensure an aseptic connection between the measuring medium and the diaphragm seal. The installation of the measuring device can accommodate direct connections, high-temperature applications via cooling elements, and capillary installations. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure Range: 0 to 4 MPa - 3-A Certified Product - Connection Standards: DIN32676, ISO2852 - Materials: SUS316L, Hastelloy - 3-A, EHEDG Certified - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Clean service application: Inline diaphragm for simultaneous measurement of temperature and pressure.

Simultaneous measurement of pressure and temperature at a single installation point. It is ideal for clean services and sanitary applications with no dead space, as well as for SIP and CIP.

At one installation location, both a mechanical pressure gauge and a pressure transmitter will be installed. To avoid dead space, a completely circular diaphragm is adopted, preventing medium retention within the process. It is used to protect pressure measuring devices in applications that use media that are difficult to measure with conventional diaphragm structures. To achieve measurements in demanding applications, we offer various designs, materials, and system filling liquids. It can withstand the cleaning steam temperatures generated in SIP processes and ensures an aseptic connection between the medium and the diaphragm seal. The diaphragm seal can be easily integrated into existing pipe surfaces to adapt to common pipe standards and nominal widths. <Product Specifications> - Simultaneous measurement of pressure and temperature at one location - Completely circular diaphragm shape that does not create dead space - Structure that allows for automatic drainage at all mounting positions - Can be quickly cleaned without leaving residues - Suitable for SIP and CIP processes. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for simultaneous measurement of temperature and pressure without dead space.

Simultaneous measurement of pressure and temperature at a single installation point. It is ideal for clean services and sanitary applications with no dead space, as well as for SIP and CIP.

Protects pressure measuring instruments used in applications with media that are difficult to measure with conventional diaphragm structures. We offer various designs, materials, and system filling liquids for measurements in harsh applications. Simultaneous measurement of pressure and temperature is possible at a single installation point. The complete circular diaphragm, which prevents dead space, contributes to quality assurance by preventing yield loss within the process. It can withstand the cleaning steam temperatures generated during SIP processes, ensuring sterile connections. The installation of measuring instruments can be done not only for mechanical pressure gauges but also for pressure transmitters. The diaphragm seal can be easily integrated into existing pipe surfaces to adapt to common pipe standards and nominal widths. <Product Specifications> - Simultaneous measurement of pressure and temperature at one location - Complete circular diaphragm shape that does not create dead space - Structure that allows automatic drainage at all mounting positions - Can be quickly cleaned without leaving residues - Suitable for SIP and CIP processes. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

In-line diaphragm for simultaneous measurement of temperature and pressure for medical and food use.

Simultaneous measurement of pressure and temperature at a single installation point. Ideal for clean services and sanitary applications with no dead space, as well as for SIP and CIP.

Simultaneous measurement of pressure and temperature at a single installation point. Ideal for clean services and sanitary applications with no dead space, as well as for SIP and CIP. <Product Specifications> - Simultaneous measurement of pressure and temperature at one location - Complete circular diaphragm shape that eliminates dead space - Structure that allows for automatic drainage at all installation positions - Quick cleaning without leaving any residue - Suitable for SIP and CIP Please refer to the product data sheet for more details.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for simultaneous measurement of temperature and pressure for sanitary use.

Simultaneous measurement of pressure and temperature at a single installation point. Ideal for clean services and sanitary applications with no dead space, as well as for SIP and CIP.

It is used to protect pressure measuring instruments in applications that use media that are difficult to measure with conventional diaphragm structures. To achieve measurements in demanding applications, we offer various designs, materials, and system filling liquids. Pressure and temperature can be measured at a single installation point. A complete circular diaphragm is adopted to avoid dead space, preventing blockage of the media within the process and contributing to quality assurance through complete cleanability. It can withstand the cleaning steam temperatures generated in SIP processes and ensures an aseptic connection between the media and the diaphragm seal. The instrument can be installed not only as a mechanical pressure gauge but also as a pressure transmitter. The diaphragm seal can be easily integrated into existing pipe surfaces to adapt to common pipe standards and nominal widths. <Product Specifications> - Simultaneous measurement of pressure and temperature at one location - Complete circular diaphragm shape that does not create dead space - Structure that allows automatic drainage at all mounting positions - Can be quickly cleaned without leaving residues - Suitable for SIP and CIP processes. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for pharmaceutical, food use / clean service applications.

An inline diaphragm with aseptic connections and no dead space in an autoclave type. Ideal for COP, SIP, and CIP.

An inline diaphragm with aseptic connection and no dead space in an autoclave type. Ideal for COP, SIP, and CIP. The installation of measuring instruments can be done via direct connection, high-temperature applications through cooling elements, and capillary mounting. The connection complies with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified - Connection standards: DIN 11864-1 DIN 11864-2 DIN 11864-3 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for sanitary / clean service applications.

An inline diaphragm with aseptic connections and no dead space in an autoclave type. Ideal for COP, SIP, and CIP.

It can withstand the cleaning steam temperature generated during the SIP process and ensures an aseptic connection between the measuring medium and the diaphragm seal due to the absence of dead space. The installation of the measuring device supports direct connection, high-temperature applications via cooling elements, and capillary mounting. The connection complies with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified product - Connection standards: DIN 11864-1 DIN 11864-2 DIN 11864-3 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation for piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for pharmaceutical and food use / without dead space.

An inline diaphragm with aseptic connections that has no dead space in an autoclave type. Ideal for COP, SIP, and CIP.

Inline diaphragm seals without dead space can be used in food, pharmaceutical, bio, and sanitary applications. We offer various designs, materials, and filling liquids that can withstand the cleaning steam temperatures generated during the SIP process. This ensures that there is always a sterile connection between the measuring medium and the diaphragm seal. The installation of measuring instruments can accommodate direct connections, high-temperature applications via cooling elements, and capillary mounting. The connection complies with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified product - Connection standards: DIN 11864-1 DIN 11864-2 DIN 11864-3 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary / No dead space inline diaphragm

An inline diaphragm with aseptic connections that has no dead space and is of autoclave type. It is ideal for COP, SIP, and CIP.

Model: 981.51 can be used in pharmaceutical and food applications that utilize media that are difficult to measure with conventional diaphragm structures. It can withstand the cleaning steam temperatures generated in SIP processes and ensures an aseptic connection between the measuring medium and the diaphragm seal. The connection complies with international standards and can be easily integrated into existing piping. <Product Details> - Pressure Range: 0 to 4 MPa - 3-A certified - Connection Standards: DIN 11864-1 DIN 11864-2 DIN 11864-3 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Aseptic Connection Inline Diaphragm for Pharmaceuticals and Food Products

An inline diaphragm with aseptic connections and no dead space in an autoclave type. Ideal for COP, SIP, and CIP.

An inline diaphragm with aseptic connection and no dead space, designed for autoclave use. Ideal for COP, SIP, and CIP applications. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified - Connection standards: DIN 11864-1 DIN 11864-2 DIN 11864-3 - Material: SUS316L - Perfect for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation for piping. Please refer to the product data sheet for more details.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Aseptic Connection Inline Diaphragm for Sanitary Use

An inline diaphragm with aseptic connections that has no dead space in an autoclave type. It is ideal for COP, SIP, and CIP.

Inline diaphragm seals can be used in applications that involve media that are difficult to measure with standard diaphragm structures. We offer a variety of designs, materials, and filling liquids, making them particularly suitable for pharmaceutical and food-related applications. They can withstand the cleaning steam temperatures generated during SIP processes and ensure an aseptic connection between the measuring medium and the diaphragm seal. The installation of the measuring device can accommodate direct connections, high-temperature applications via cooling elements, and capillary mounting. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified product - Connection standards: DIN 11864-1 DIN 11864-2 DIN 11864-3 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for pharmaceutical, food, and clean service applications.

3-A, EHEDG, FDA certified product. No dead space, inline diaphragm for clean service. Ideal for SIP and CIP as well.

This is an inline diaphragm seal suitable for use in pharmaceutical, food, and clean service applications. We offer various designs, materials, and filling liquids for media applications that are difficult to measure with standard diaphragm structures. It is particularly ideal for pharmaceuticals, food, biotechnology, and cleanroom-related applications. It can withstand the cleaning steam temperatures generated during the SIP process and ensures a sterile connection between the measuring medium and the diaphragm seal. The installation of measuring instruments can accommodate direct connections, high-temperature applications via cooling elements, and capillary mounting. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure Range: 0 to 4 MPa - 3-A Certified Product - Connection Standards: NEUMO BioConnect, ISO 1127, DIN 11850, 11866 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - Quick cleaning with no residual impurities. - Dead space-free installation for piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for sanitary/cleaning service applications.

3-A, EHEDG, FDA certified product. No dead space, inline diaphragm for clean services. Ideal for SIP and CIP as well.

The instrument features a direct connection, suitable for high-temperature applications via a cooling element, and can be installed with a capillary inline diaphragm seal. The connection complies with international standards, making it easy to install onto existing piping. It can be used in applications that utilize media that are difficult to measure with conventional diaphragm structures. We offer a variety of designs, materials, and filling liquids, making it particularly suitable for pharmaceutical and food-related applications. It can withstand the cleaning steam temperatures generated during the SIP process and ensures an aseptic connection between the measuring medium and the diaphragm seal. <Product Details> - Pressure Range: 0 to 4 MPa - 3-A certified product - Connection Standards: NEUMO BioConnect ISO 1127 DIN 11850, 11866 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[For pharmaceuticals and food / No dead space] Inline diaphragm

3-A, EHEDG, FDA certified products. No dead space, inline diaphragm for clean service. Ideal for SIP and CIP as well.

It can be used in pharmaceutical and food applications that utilize media that are difficult to measure with conventional diaphragm structures. It can withstand the cleaning steam temperatures generated during the SIP process, ensuring an aseptic connection between the measuring medium and the diaphragm seal. We offer a variety of designs, materials, and filling liquids, making it particularly suitable for pharmaceutical and food-related applications. The installation of the measuring device accommodates not only direct connections but also high-temperature applications through cooling elements and capillary mounting. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure Range: 0–4 MPa - 3-A Certified - Connection Standards: NEUMO BioConnect ISO 1127 DIN 11850, 11866 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary / No Dead Space Inline Diaphragm

3-A, EHEDG, FDA certified product. No dead space, inline diaphragm for clean services. Ideal for SIP and CIP as well.

The inline diaphragm seal without dead space can be used in sanitary applications that involve media that are difficult to measure with conventional diaphragm structures. We offer various designs, materials, and filling liquids to meet your specific requirements. It can withstand the cleaning steam temperatures generated during the SIP process and ensures a sterile connection between the measuring medium and the diaphragm seal. The installation of the measuring device can be done directly, and it is compatible with high-temperature applications with cooling elements and capillary installations. The connection complies with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified product - Connection standards: NEUMO BioConnect, ISO 1127, DIN 11850, 11866 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

In-line diaphragm seal for pharmaceuticals and food applications

3-A, EHEDG, FDA certified products. No dead space, inline diaphragm for clean service. Ideal for SIP and CIP as well.

Model: 981.50 can be used in pharmaceutical and food applications that utilize media that are difficult to measure with conventional diaphragm structures. We offer a variety of designs, materials, and filling liquids. It can withstand the cleaning steam temperatures generated during the SIP process, ensuring an aseptic connection between the measuring medium and the diaphragm seal. The installation of the measuring device can accommodate direct connections, high-temperature applications via cooling elements, and capillary installations. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified product - Connection standards: NEUMO BioConnect ISO 1127 DIN 11850, 11866 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary inline diaphragm seal

3-A, EHEDG, FDA certified product. No dead space, inline diaphragm for clean service. Ideal for SIP and CIP as well.

Inline diaphragm seals can be used in applications that utilize media that are difficult to measure with standard diaphragm structures. We offer a variety of designs, materials, and filling liquids, making them particularly suitable for pharmaceutical and food-related applications. They can withstand the cleaning steam temperatures generated during SIP processes and ensure an aseptic connection between the measuring medium and the diaphragm seal. The installation of the measuring device can accommodate direct connections, high-temperature applications via cooling elements, and capillary mounting. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: 0 to 4 MPa - 3-A certified - Connection standards: NEUMO BioConnect, ISO 1127, DIN 11850, 11866 - Material: SUS316L - Ideal for COP, SIP, and CIP applications. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary temperature measuring resistance thermometer, clean service application TR25

A structure that prevents contamination allows for rapid cleaning. Suitable for SIP and CIP applications. Achieves high precision with fast response speed. Complies with explosion-proof standards.

With various process connections, it can be easily installed on many different processes without any issues. The structure prevents contamination and allows for rapid cleaning. It is compatible with SIP and CIP. It achieves high precision with a fast response time and complies with explosion-proof standards. <Product Details> - Hygienic design with no dead space - No residue at measurement points, allowing for rapid cleaning (compliant with SIP and CIP) - Quality of materials and surface finish in accordance with hygienic design standards - Quality of materials and surface finish compliant with pharmaceutical industry directives and standards - High precision achieved with a short response time - Explosion-proof specifications available as an option For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

"Temperature measuring resistance thermometer for medical and food use, clean service applications" TR25

A structure that prevents contamination allows for rapid cleaning. Suitable for SIP and CIP. Achieves high precision with a fast response time. Complies with explosion-proof standards.

The TR25 RTD with an inline diaphragm seal is used in pharmaceutical, food, and cleanroom applications where pipelines and thermowells have very high hygiene requirements. Its structure prevents contamination and allows for rapid cleaning. It is compatible with SIP and CIP, and achieves fast response times and high-precision measurements. It also complies with explosion-proof standards. <Product Details> - Hygienic design that is free of dead space - No residuals at the measurement point, allowing for rapid cleaning (compliant with SIP and CIP) - Quality of materials and surface finish compliant with hygienic design standards - Quality of materials and surface finish compliant with pharmaceutical industry directives and standards - High precision achieved with short response times - Explosion-proof specifications available as an option For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pharmaceutical and food RTD, clean service applications TR25

A structure that prevents contamination allows for rapid cleaning. Suitable for SIP and CIP applications. Achieves high precision with a fast response time. Also complies with explosion-proof standards.

The structure prevents contamination and allows for rapid cleaning. It is compatible with SIP and CIP. It achieves high precision with a fast response time. The TR25, which meets explosion-proof standards, is used in applications with pipelines and thermowells that have strict hygiene requirements. It can handle media that are difficult to immerse in the process medium and very stringent flow conditions in pipes. For example, high viscosity is desirable in piggable pipelines. It accommodates a wide variety of process connections and can be installed in many processes without issues. <Product Details> - Hygienic design with no dead space - No residuals at the measurement point, allowing for rapid cleaning (compliant with SIP and CIP) - Quality of materials and surface finish compliant with hygienic design standards - Quality of materials and surface finish compliant with pharmaceutical industry directives and standards - High precision with a short response time - Explosion-proof specifications available as an option For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary RTD, clean service application TR25

A structure that prevents contamination allows for rapid cleaning. Suitable for SIP and CIP. Achieves high precision with a fast response time. Complies with explosion-proof standards.

This thermometer is used in applications where pipelines and thermowells have very high hygiene requirements. The reason is that it can handle media that are difficult to immerse in the process medium and very harsh flow conditions in the pipes. For example, high-viscosity media are desirable in piggable pipelines. With a variety of process connections, it can be installed in many different processes without any issues. <Product Details> - Free of dead space and hygienic design - No residuals at the measurement point, allowing for rapid cleaning (compliant with SIP and CIP) - Quality of materials and surface finish compliant with hygienic design standards - Quality of materials and surface finish compliant with pharmaceutical industry directives and standards - High accuracy achieved with a short response time - Explosion-proof specifications available as an option For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for pharmaceutical and food applications / clean service use

Easy installation into the pipeline with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications.

Inline diaphragm seals can be used for pharmaceutical and food applications / clean service applications. We offer a variety of designs, materials, and filling liquids. Instrument installation can be done via direct connection, for high-temperature applications with cooling elements, and capillary type connections are also possible. They can be easily integrated into existing piping systems as they comply with national connection standards. <Product Details> - Pressure range: Supports 0 to 4 MPa. - 3-A certified product - Connection standards: ISO 1127 row 2, ISO 2037/1992, DIN 11851, ISO 2853, BS 4825 part 4 - Ideal for COP, SIP, and CIP applications. - Self-draining capability at all installation positions. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm for sanitary/cleaning services

Easy installation into pipelines with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications.

The inline diaphragm seal for sanitary and cleanroom applications can be used in applications that utilize media that are difficult to measure with standard diaphragm structures. It can withstand the cleaning steam temperatures generated during the SIP process and ensures a sterile connection between the measuring medium and the interior of the diaphragm seal. The installation of the measuring device can be done directly, and it also supports capillary installation for verification purposes in high-temperature environments through cooling elements, even at locations away from the installation site. The connection standards comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: Supports 0 to 4 MPa. - 3-A certified product. - Connection standards: ISO 1127 row 2, ISO 2037/1992, DIN 11851, ISO 2853, BS 4825 part 4. - Ideal for COP, SIP, and CIP applications. - Self-draining capability at all installation positions. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Pharmaceuticals and Food Use / No Dead Space】Inline Diaphragm

Easy installation into pipelines with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications.

The inline diaphragm seals for pharmaceutical and food applications are available in various designs, materials, and filling liquids. They are compatible with the cleaning steam temperatures generated during the SIP process and ensure an aseptic condition between the measuring medium and the diaphragm seal. The installation of measuring instruments can be done via direct connection, high-temperature applications through cooling elements, and capillary mounting. The connection points comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: Supports 0 to 4 MPa. - 3-A certified product - Connection standards: ISO 1127 row 2, ISO 2037/1992, DIN 11851, ISO 2853, BS 4825 part 4 - Ideal for COP, SIP, and CIP applications. - Self-draining capability at all mounting positions. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary use / No dead space Inline diaphragm

Easy installation into the pipeline with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications.

The sanitary inline diaphragm seal can be easily installed into pipelines and features a diaphragm structure with no dead space. It is ideal for COP, SIP, and CIP applications. The installation of measuring instruments can be done through direct connection, high-temperature applications via cooling elements, and capillary mounting. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: Supports 0 to 4 MPa. - 3-A certified product. - Connection standards: ISO 1127 row 2, ISO 2037/1992, DIN 11851, ISO 2853, BS 4825 part 4. - Ideal for COP, SIP, and CIP applications. - Self-draining capability at all mounting positions. - No residual impurities, allowing for quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm seal 981 series for pharmaceuticals and food applications

Easy installation into pipelines with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications.

Easy installation into pipelines with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications. <Product Details> - Pressure range: Supports 0 to 4 MPa. - 3-A certified product - Connection standards: ISO 1127 row 2 ISO 2037/1992 DIN 11851 ISO 2853 BS 4825 part 4 - Ideal for COP, SIP, and CIP applications. - Self-draining capability at all installation positions. - No residual impurities, quick cleaning. - Dead space-free installation in piping. Please refer to the product data sheet for more details.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline diaphragm seal 981 series for sanitary use

Easy installation into pipelines with a diaphragm structure that has no dead space. Ideal for COP, SIP, and CIP applications.

Inline diaphragm seals can be used in applications that utilize media that are difficult to measure with standard diaphragm structures. We offer a variety of designs, materials, and filling liquids, making them particularly suitable for pharmaceutical and food-related applications. They can withstand the cleaning steam temperatures generated during SIP processes and ensure an aseptic connection between the measuring medium and the diaphragm seal. The installation of the measuring device can accommodate direct connections, high-temperature applications via cooling elements, and capillary installations. The connection parts comply with international standards and can be easily integrated into existing piping. <Product Details> - Pressure range: Supports 0 to 4 MPa. - 3-A certified product - Connection standards: ISO 1127 row 2, ISO 2037/1992, DIN 11851, ISO 2853, BS 4825 part 4 - Ideal for COP, SIP, and CIP applications. - Self-draining capability at all mounting positions. - No residual impurities, quick cleaning. - Dead space-free installation in piping. For more details, please refer to the product data sheet.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Pharmaceutical and Food Use] NEUMO BioControl Flange

NEUMO BioControl connection housing, flange. Designed without dead space and hygienically, compliant with pharmaceutical industry standards.

The pharmaceutical-grade BioControl system provides housings and flanges to adapt pressure and temperature measuring devices to pipelines and containers, specifically developed for aseptic processes. To meet the advanced requirements of aseptic processes, various designs of the BioControl system are available and have received type certification. - Housing (G) A flow-through housing with a welded end for direct orbital welding to the pipeline (process connection). By using two aseptic flange connections, it allows for the connection of pressure and temperature gauges without dead space, complying with hygienic standards. - Housing, angled variant (U) A 90° angled variation of the flow-through housing. It is particularly suitable for connecting temperature gauges with a long insertion length. - Mounting flange (B) Developed for mounting pressure and temperature gauges to aseptic equipment. It allows for the installation of devices without creating dead space in the container. - Blind flange (D) Seals the housing or the angled housing variant.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Pharmaceutical and Food Use] NEUMO BioControl Housing

NEUMO BioControl connection housing, flange. Designed without dead space and in a hygienic manner, compliant with pharmaceutical industry standards.

The NEUMO BioControl connection housing offers various designs of the BioControl system to meet the advanced requirements of aseptic processes and has obtained type certification. - Housing (G) This is a flow-through housing equipped with a welded end for direct orbital welding to the pipeline (process connection). By using two aseptic flange connections, it allows for the connection of pressure and temperature gauges without dead space, complying with hygienic standards. - Housing, angled variant (U) This is a 90° angled variation of the flow-through housing. It is particularly suitable for connecting temperature gauges with a long insertion length. - Mounting flange (B) Developed for mounting pressure and temperature gauges to aseptic equipment. It allows for the installation of equipment without creating dead space in the container. - Blind flange (D) Seals the housing or the angled housing variant.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Sanitary Use] NEUMO BioControl Flange

NEUMO BioControl connection housing, flange. Designed without dead space and hygienically, compliant with pharmaceutical industry standards.

The BioControl system, ideal for pharmaceutical and food applications, has developed housings and flanges for connecting pressure and temperature instruments for aseptic processes. We offer various designs of the BioControl system to meet the advanced requirements of aseptic processes. - Housing (G) This is a flow-through housing equipped with a welded end for direct orbital welding to the pipeline (process connection). By using two aseptic flange connections, it allows for the connection of pressure and temperature instruments without dead space and in compliance with hygienic standards. - Housing, angled variant (U) This is a 90° angled variant of the flow-through housing. It is particularly suitable for connecting temperature instruments with a long insertion length. - Mounting flange (B) Developed for mounting pressure and temperature instruments to aseptic equipment. It allows for the installation of equipment without creating dead space in the container. - Blind flange (D) Seals the housing or the angled housing variant.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Sanitary Use] NEUMO BioControl Housing

NEUMO BioControl connection housing, flange. Designed without dead space and hygienically, compliant with pharmaceutical industry standards.

The BioControl system for sanitary applications has been specially developed to optimally integrate pressure and temperature measuring devices for aseptic processes into pipelines and containers, providing housings and flanges. To meet the advanced requirements of aseptic processes, various designs of the BioControl system are available and have received type certification. - Housing (G) This is a flow-through housing equipped with a welded end for direct orbital welding to pipelines (process connections). By using two aseptic flange connections, it allows for the connection of pressure and temperature sensors without dead space, complying with hygienic standards. - Housing, angled variant (U) This is a 90° angled variation of the flow-through housing. It is particularly suitable for connecting temperature sensors with a long insertion length. - Mounting flange (B) This has been developed to mount pressure and temperature sensors onto aseptic equipment. It allows for the installation of devices without creating dead space in the container. - Blind flange (D) This seals the housing or the angled housing variant.

  • Fittings

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pressure gauge PG43SA-D with diaphragm rupture detection function for pharmaceuticals and food.

A diaphragm pressure gauge with a diaphragm rupture detection feature, compact design, and excellent cleanability, making it ideal for use in SIP and CIP processes.

This is a pressure gauge with diaphragm rupture detection functionality designed for the pharmaceutical and food industries. Its compact and easy-to-clean design makes it ideal for use in SIP and CIP processes. The monitoring system, which meets the highest safety requirements, immediately displays a warning mark when a diaphragm rupture is detected, minimizing risks. <Product Details> - Range: 0–2.5bar....0–16bar -1–+1.5bar...-1–+15bar - Accuracy: Class 1.6 - Allowable ambient temperature: -20–+60℃ - Allowable media temperature: -30–+150℃ - Protection rating: IP54 - Connection standards: Clamp connection DIN 32676 / BS4825 part 3 Aseptic connection DIN 11864-1 /-2 /-3 Milk screw connection DIN 11851 VARINLINE NEUMO BioControl SMS threaded connection For more details, please refer to the product data sheet. [Pressure gauge PG43SA-D with diaphragm rupture detection functionality for pharmaceutical and food use]

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary Pressure Gauge PG43SA-D with Diaphragm Rupture Detection Function

A diaphragm pressure gauge with a diaphragm rupture detection feature, compact design, and excellent cleanability, making it ideal for use in SIP and CIP processes.

The diaphragm rupture detection function refers to a monitoring system that has obtained patents in the pharmaceutical and biotech industries. When a rupture in the diaphragm is detected, a red warning mark is displayed immediately, minimizing the risks after the rupture. If the pressure element is intact, it remains displayed in white. <Product Details> - Range: 0–2.5 bar....0–16 bar -1–+1.5 bar...-1–+15 bar - Accuracy: Class 1.6 - Allowable ambient temperature: -20 to +60℃ - Allowable media temperature: -30 to +150℃ - Protection rating: IP54 - Connection standards: Clamp connection DIN 32676 / BS4825 part 3 Aseptic connection DIN 11864-1 /-2 /-3 Milk screw connection DIN 11851 VARINLINE NEUMO BioControl SMS threaded connection For more details, please refer to the product data sheet. [With diaphragm rupture detection function] Sanitary pressure gauge PG43SA-D

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Diaphragm Pressure Gauge for Medical and Food Use PG43SA-D

A diaphragm pressure gauge with a diaphragm rupture detection feature, compact design, and excellent cleanability, making it ideal for use in SIP and CIP processes.

The monitoring system, certified for the pharmaceutical and biotechnology industries, displays a red warning mark as soon as a diaphragm rupture is detected. If this mark remains white, it indicates that the pressure element is intact. It is also ideal for CIP and SIP cleaning, ensuring thorough cleaning due to its design that eliminates dead spaces. Submission of standard documents compliant with GMP, such as material certificates, is also possible. <Product Details> - Range: 0–2.5 bar....0–16 bar -1 to +1.5 bar...-1 to +15 bar - Accuracy: Class 1.6 - Permissible ambient temperature: -20 to +60℃ - Permissible media temperature: -30 to +150℃ - Protection rating: IP54 - Connection standards Clamp connection DIN 32676 / BS4825 part 3 Aseptic connection DIN 11864-1 /-2 /-3 Milk screw connection DIN 11851 VARINLINE NEUMO BioControl SMS threaded connection For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary Diaphragm Pressure Gauge PG43SA-D

A diaphragm pressure gauge with a diaphragm rupture detection feature, designed to be compact and easy to clean, making it ideal for use in SIP and CIP processes.

The monitoring system, which meets the highest safety requirements and has obtained patents in the pharmaceutical and biotechnology industries, displays a warning mark as soon as a diaphragm rupture is detected, minimizing risks. If this mark remains white, it indicates that the pressure element is intact. In CIP and SIP applications, cleaning can be performed reliably without creating dead spaces. Submission of documentation compliant with GMP, such as material certificates, is also possible. <Product Details> - Range: 0–2.5bar....0–16bar -1–+1.5bar...-1–+15bar - Accuracy: Class 1.6 - Permissible ambient temperature: -20–+60℃ - Permissible media temperature: -30–+150℃ - Protection rating: IP54 - Connection standards Clamp connection DIN 32676 / BS4825 part 3 Aseptic connection DIN 11864-1 /-2 /-3 Milk screw connection DIN 11851 VARINLINE NEUMO BioControl SMS threaded connection Please refer to the product data sheet for more details.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Medical and food use temperature measuring resistance thermometer Inline type RTD TR25

A structure that prevents contamination allows for rapid cleaning. Suitable for SIP and CIP applications. Achieves high precision with a fast response time. Complies with explosion-proof standards.

TR25 can be used in applications installed in pipelines with very high hygiene requirements for the pharmaceutical and food industries. It has proven effective even in pipeline conditions where it is difficult to immerse the medium in the process or where very strict flow rates are involved. For example, in piggable pipelines, high viscosity is desirable. With a variety of process connections, it can be easily installed in many different processes without any issues. <Product Details> - Dead space-free and hygienic design - No residuals at the measurement point, allowing for rapid cleaning (compliant with SIP and CIP) - Quality of materials and surface finishes compliant with hygienic design standards - Quality of materials and surface finishes compliant with pharmaceutical industry directives and standards - High precision achieved with a short response time - Explosion-proof specifications available as an option For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Sanitary RTD, no dead space] TR25

A structure that prevents contamination allows for rapid cleaning. Suitable for SIP and CIP applications. Achieves high precision with a fast response time. Complies with explosion-proof standards.

This thermometer is used in applications where pipelines and thermowells have very high hygiene requirements. The reason is that it can handle media that are difficult to immerse in the process medium and pipeline conditions with very strict flow rates. For example, high-viscosity media are desirable in piggable pipelines. With a variety of process connections, it can be installed without issues in many different processes. <Product Details> - Dead space-free and hygienic design - No residuals at the measurement point, allowing for rapid cleaning (compliant with SIP and CIP) - Quality of materials and surface finish compliant with hygienic design standards - Quality of materials and surface finish compliant with pharmaceutical industry directives and standards - High accuracy with a short response time - Explosion-proof version available as an option For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Medical and food pressure gauge - Diaphragm pressure gauge PG43SA-C

A diaphragm pressure gauge with a compact and easy-to-clean design that does not use transmission fluid, making it ideal for use in SIP and CIP processes.

The PG43SA-C is an ideal product for customers who require reliable cleaning without creating dead space in CIP and SIP applications. Of course, submission of specification documents compliant with GMP is also possible. Thanks to its special design that meets hygienic requirements, it can be used without any issues in pharmaceutical and food-related applications. Since neither the body nor the diaphragm section uses transmission fluid, there is no risk of contamination, and internal cleaning of the product is unnecessary. The diaphragm element process connections, which are welded in a sterile state (e.g., clamp, threaded, VARIVENT, BioControl), enable connections without dead space. <Product Details> - Size: 63mm - Range: +1 to 2bar, -1 to +4bar, -1 to +9bar, 0 to 3bar, 0 to 5bar, 0 to 10bar *It supports SI units such as MPa, Pa, psi, etc., so please feel free to consult us. - Usable Temperature Ambient: -20 to +60 °C Medium: -20 to +150 °C - Accuracy: Class 2.5 - Protection Rating: IP66 For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary Pressure Gauge Diaphragm Type Pressure Gauge PG43SA-C

A diaphragm pressure gauge with a compact and easy-to-clean design that does not use transmission fluid, making it ideal for use in SIP and CIP processes.

The PG43SA-C is specially designed to meet hygienic requirements and is suitable for pharmaceutical and food-related applications. Since neither the body nor the diaphragm section uses transmission fluid, there is no risk of contamination, and internal cleaning of the product is unnecessary. The diaphragm element process connections, which are welded in a sterile state (e.g., clamp, threaded, VARIVENT, BioControl), allow for connections without dead space. In CIP and SIP applications, the absence of dead space ensures effective cleaning. Documentation compliant with GMP standards can also be provided. <Product Details> - Size: 63mm - Range: +1 to 2bar, -1 to +4bar, -1 to +9bar, 0 to 3bar, 0 to 5bar, 0 to 10bar *We can accommodate SI units such as MPa, Pa, psi, etc., so please feel free to consult us. - Operating Temperature Ambient: -20 to +60 °C Medium: -20 to +150 °C - Accuracy: Class 2.5 - Protection Rating: IP66 For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Diaphragm Pressure Gauge for Medical and Food Use PG43SA-C

A diaphragm pressure gauge with a compact and easy-to-clean design that does not use transmission fluid, making it ideal for use in SIP and CIP processes.

The PG43SA-C features a diaphragm element process connection that is welded in a sterile environment (e.g., clamp, threaded, VARIVENT, BioControl), allowing for connections without dead space. In CIP and SIP applications, its design prevents the creation of dead space, enabling thorough cleaning that eliminates yield loss. Compliance with GMP standards for documentation submission is also possible. It is specially designed to meet hygienic requirements and is suitable for pharmaceutical and food-related applications without any issues. Since neither the body nor the diaphragm section uses transmission fluid, there is no risk of contamination, and internal cleaning of the product is unnecessary. <Product Details> - Size: 63mm - Range: +1 to 2bar, -1 to +4bar, -1 to +9bar, 0 to 3bar, 0 to 5bar, 0 to 10bar *We can accommodate SI units such as MPa, Pa, psi, etc., so please feel free to consult us. - Usable Temperature Ambient: -20 to +60 °C Medium: -20 to +150 °C - Accuracy: Class 2.5 - Protection Rating: IP66 For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary Diaphragm Pressure Gauge PG43SA-C

A diaphragm pressure gauge with a compact and easy-to-clean design, ideal for use in SIP and CIP processes, that does not use transmission fluid.

The PG43SA-C features a compact and easy-to-clean design that does not use transmission fluid, making it suitable for pharmaceutical and food-related applications. There is no risk of contamination, and internal cleaning of the product is unnecessary. The diaphragm element process connections, which are welded in a sterile state (e.g., clamp, threaded, VARIVENT, BioControl), allow for connections without dead space. This ensures effective cleaning in CIP and SIP applications by eliminating dead space. Documentation compliant with GMP standards can also be provided. <Product Details> - Size: 63mm - Range: +1 to 2bar, -1 to +4bar, -1 to +9bar, 0 to 3bar, 0 to 5bar, 0 to 10bar *We can accommodate SI units such as MPa, Pa, psi, etc., so please feel free to consult us. - Usable Temperature Ambient: -20 to +60 °C Medium: -20 to +150 °C - Accuracy: Class 2.5 - Protection Rating: IP66 For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sanitary Gas-Filled Thermometer Model 74

We provide high quality with a hygienic design free of dead space, using materials and surface finishes that comply with 3-A and CRN standards.

The Model 74 gas-filled mechanical thermometer is an ideal product to meet the special requirements of the food, bio, and pharmaceutical industries. It is certified by a third-party organization under the 3-A and CRN standards, and the certification mark is displayed on the product. The stem and case are made of stainless steel. The wetted part surface is electropolished, making it suitable for various connection standards, and it is optimal for many food and pharmaceutical process requirements, with a design that eliminates dead space in the stem. <Product Details> - Temperature Range: -30 to +60°C -20 to +100°C 0 to 120°C 0 to 160°C - Accuracy: ±1°C - Ambient Temperature: -40 to +60 °C 0 to +60 °C (for food-grade filling liquids) - Dead space-free and hygienic product design - Compatible with aseptic process connections - High quality due to materials and surface finishes compliant with sanitary design standards For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Gas-filled thermometer for medical and food use Model 74

We provide high quality with a hygienic design free of dead space, using materials and surface finishes that comply with 3-A and CRN standards.

Model74 is designed to meet the special requirements of the food, bio, and pharmaceutical industries while fulfilling the functions of a standard thermometer. It is an ideal thermometer that, despite being a gas-filled type, meets the high standards required for sanitary applications. The thermometer has been certified by a third-party organization as compliant with 3-A standards, and the certification mark is clearly indicated on the product. The stem and case are made of stainless steel. The wetted surface is electropolished, making it suitable for various connection standards, and it is optimal for many food and pharmaceutical process requirements, with a design that eliminates dead space in the stem. <Product Details> - Temperature Range: -30 to +60°C -20 to +100°C 0 to 120°C 0 to 160°C - Accuracy: ±1°C - Ambient Temperature: -40 to +60 °C 0 to +60 °C (for food-grade filling liquids) - Dead space-free and hygienic product design - Aseptic process connection compatible - High quality due to materials and surface finishes compliant with sanitary design standards For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[3-A, CRN Compliant] Sanitary Mechanical Thermometer Model 74

We provide high quality with a hygienic design free of dead space, using materials and surface finishes that comply with 3-A and CRN standards.

The Model 74, compliant with CRN standards, is designed to meet the special requirements of the food, bio, and pharmaceutical industries. It is an ideal thermometer that, while being a gas-filled type, meets the high standards of the sanitary industry. The stem is made of stainless steel, and the wetted part surface is electropolished, making it suitable for various connection standards. It is optimal for many food and pharmaceutical process requirements, and the stem is designed to eliminate dead space. <Product Details> - Temperature Range: -30 to +60°C -20 to +100°C 0 to 120°C 0 to 160°C - Accuracy: ±1°C - Ambient Temperature: -40 to +60 °C 0 to +60 °C (for food filling liquids) - Dead space-free and hygienic product design - Aseptic process connection compatibility - High quality through materials and surface finishes compliant with sanitary design standards For more details, please refer to the product data sheet.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Prev 1...789...15 Next
  • イプロスがリアル展示会を主催します! AI/DX 営業・マーケティング展 出展社募集中 リード数・商談数が止まらない!新しいリアル展示会を提供 会期 2026年3月24日(火)~25日(水) 会場 東京ビッグサイト東4ホール 出展概要資料を進呈!
    • Contact this company

      Contact Us Online

    Products

    • Search for Products

    Company

    • Search for Companies

    Special Features

    • Special Features

    Ranking

    • Overall Products Ranking
    • Overall Company Ranking

    support

    • site map
    IPROS
    • privacy policy Regarding external transmission of information
    • terms of service
    • About Us
    • Careers
    • Advertising
    COPYRIGHT © 2001-2025 IPROS CORPORATION ALL RIGHTS RESERVED.
    Please note that the English text on this page is automatically translated and may contain inaccuracies.