Visualize gas leaks such as gasoline vapor, methane, toluene, and ethanol! Non-cooling thermal imaging camera thermometer.
■There are variations depending on the gas detected.
◇Model: G600C
Infrared spectral band: 7.0 to 8.5 μm
Detectable gases: Methane, nitrous oxide, sulfur dioxide, toluene, ethanol, ethyl acrylate, 2-ethylhexyl acrylate, freon (R13, R13B1, R123, R125, R134A, R417A, R422A, etc.)
◇Model: G600F
Infrared spectral band: Center wavelength of 10.55 μm
Detectable gases: Sulfur hexafluoride, ammonia, ethylene, ethylene ether, vinyl chloride, trichloroethylene, methyl vinyl ketone, propylene, acrolein, acrylonitrile, ethyl cyanoacrylate, allyl fluoride, allyl chloride, furan, etc.
■Explosion-proof specifications
With Ex ic 2C T4 explosion-proof specifications, it can be safely used in industrial fields such as petroleum, petrochemicals, and natural gas.
CNEX National Explosion-proof Certification No. CNEx22.4252X
■Gasoline vapor detection
https://youtu.be/2LLM_KRAUN0
■C2H4 gas leak detection
https://youtu.be/BuHpcb1Uoi8