46~90 item / All 125 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online46~90 item / All 125 items
- The push head is small, making it easy to integrate into compact devices. - It has a built-in contact block, featuring a slim design that does not take up space on the back of the panel. - A wide temperature range from -25 to 70°C. - With a waterproof structure (IP65 / IP67 / IP69K), it can be safely used in outdoor equipment.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWith the IoT transformation of factories, machine tools have started to be manufactured as models that connect to computers via LAN cables for programming and data extraction. However, common connectors tend to malfunction quickly. The environment in which machine tools are used can sometimes have operating oils that become mist-like, so waterproof, high-durability connectors have been adopted. An angle-type connector that changes the cable exit by 90 degrees has been implemented, allowing for more effective use of the limited space in machine tools. 【Case Study】 ■Challenges - Common connectors tend to malfunction quickly. ■Countermeasures - Introduced LAN cable connectors that are resistant to operating oils and have high waterproof capabilities. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationRegarding the connectorization of the power supply points, after trying various connectors, we faced issues with poor conductivity due to welding in harsh usage environments (temperatures above 80°C and humidity of 70-80%) while conducting large currents (700-1000A) with standard connectors. By adopting high-current connectors, we completely eliminated the occurrence of conductivity issues during high-current conduction in harsh usage environments. Additionally, the special spring contacts of the high-current connectors allowed us to significantly reduce size and weight compared to conventional connectors, which has contributed to reducing the burden on workers in the field, such as alleviating back pain, and minimizing operational errors like incorrect connections. It has become an indispensable item during equipment updates. [Case Study] ■ Issues - Poor conductivity due to welding occurs with standard connectors. ■ After Implementation - No occurrences of conductivity issues during high-current conduction in harsh usage environments. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDue to heat, oil, and dust, the locking part has become stiff and difficult to detach. This is particularly problematic in hydraulic and grease piping, where liquid leakage during detachment can lead to air and foreign substances entering the system. To address this, a one-touch coupling was adopted at the piping connection points of the rolling equipment, which minimizes liquid leakage and air intrusion during detachment. As a result, the work of detaching and attaching the piping has become easier, and the absence of liquid leakage has eliminated the sticking of the locking part, improving the issues at the connection points themselves. [Case Study] ■ Issues - Liquid leakage to the outside and air/foreign substances entering the inside during coupling detachment. ■ After Implementation - Work during piping detachment has become easier. - Issues at the connection points have also been improved. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt the steel mill's lifter crane, connectors were breaking every three to six months, making maintenance cumbersome. Therefore, we adopted our one-touch coupling waterproof connector. The method of attaching and detaching is now one-touch, eliminating concerns about wear on the screw threads, and the size of the connector itself has become even more compact, significantly improving work efficiency on-site. Additionally, it can be used without any issues even when exposed to rain or sea breeze, and it has been functioning without maintenance for over five years. [Case Study] ■Challenges - Connectors break every three to six months, making maintenance cumbersome. ■After Implementation - Work efficiency on-site has significantly improved. - It has been functioning without maintenance for over five years. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe press line experiences significant vibrations, which sometimes causes poor electrical contact at the connector between the moving bolster and the press machine, leading to line stoppages. To prevent connection failures, a special connector was introduced that uses springs to maintain a constant contact pressure at the connection point. Previously, the line frequently stopped, but after the introduction of this connector, there have been no instances of poor electrical contact. Additionally, workers originally connected the connectors manually, but by enabling automatic connection and disconnection, the burden on employees was reduced, leading to increased productivity. [Case Study] ■ Issues - Poor electrical contact at the connector of the moving bolster on the press line ■ After Implementation - No instances of poor electrical contact - Reduced burden on employees and increased productivity *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe electrical connector for the transport device of the press machine was originally designed for automatic connection, but it was a push-type connection. However, due to severe vibrations, contact failures occurred, causing the line to stop, which was problematic. The coupling was very fragile and needed to be replaced frequently. Therefore, we introduced a combined electrical and air connector, and by adding a guide, we were able to correct misalignment and prevent damage during attachment and detachment. Additionally, compared to the connectors and couplings used previously, they have become significantly more durable, eliminating electrical contact issues, which has allowed for smoother operations on-site. [Case Study] ■ Issues - Connectors and couplings on the press line break easily ■ After Implementation - Attachment and detachment operations have become smoother *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe welding robot has six joint parts, three of which are connected by connectors, but there were issues with poor electrical conductivity due to faulty connections. To address this, a special spring connector that maintains consistent contact pressure was introduced. After the introduction, there were no more electrical conductivity issues at all. Additionally, the equipment personnel used to remove the connectors for maintenance, but with the spot welding connectors, only the cables can be detached, eliminating the hassle of removing the connectors and significantly reducing time and effort. 【Case Study】 ■Issue - Poor electrical conductivity due to faulty connector connections ■After Implementation - No more electrical conductivity issues at all *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe welding transfer device and jig were each connected with electrical connectors and air couplings. Previously, electricity and air were manually connected and disconnected separately, but by combining air and electricity, it became possible to do it in one process. Additionally, by sliding the connector on the rail, it became possible to automatically connect and disconnect. The contacts use a special spring connector that maintains a constant contact pressure, resulting in a longer lifespan and reduced frequency of replacement compared to the connectors previously used. [Case Study] ■Challenges - Wanted to consolidate the connectors and couplings on the welding line. ■After Implementation - Adopted a high-durability connector that allows for automatic connection and disconnection, reducing running costs. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe workers were manually connecting the electrical connectors of the engine test bench's pallet and testing equipment, as well as the couplings for fuel, air couplings for exhaust gas recovery, and couplings for cooling water. Since there are couplings of the same size, there was a risk of incorrect connections, leading to the introduction of an automatic multi-coupling system. As a result, we implemented couplings that do not leak liquid, allowing us to consolidate everything into a multi-coupling system, significantly reducing work time. 【Case Study】 ■Challenge - To consolidate all connectors and couplings on the engine test line. ■After Implementation - Consolidated everything into a multi-coupling system. - Achieved a significant reduction in work time. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWhen replacing the die-casting machine's mold core, multiple hydraulic circuits are connected. However, the coupling of the hydraulic circuits is subjected to high pressure, making it prone to breakage, so we kept spare couplings on hand. Additionally, during attachment and detachment, oil tends to leak, requiring workers to clean it up. If oil leaks, air can mix into the hydraulic hoses, necessitating regular maintenance to bleed the air. Therefore, we introduced a multi-coupling that does not leak. This reduced the workload for workers and shortened the working time. [Case Study] ■ Issues - Hydraulic leaks in the casting line made maintenance difficult. ■ After Implementation - Reduced the workload for workers. - Shortened the working time. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSince we strictly manage the takt time, the workers are rushing their tasks, which inevitably leads to mistakes and losses. Additionally, when inexperienced workers take over, the number of errors tends to increase, causing further issues. To reduce mistakes during mold changes, we introduced a multi-coupling system. This allows all 20 units to be attached and detached simultaneously with a lever. As a result, even inexperienced workers no longer make mistakes, and we were able to significantly shorten the takt time. [Case Study] ■ Challenges - We wanted to reduce mistakes during injection molding mold changes. ■ After Implementation - Even inexperienced workers no longer make mistakes, and we were able to significantly shorten the takt time. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe received an inquiry regarding the multi-coupling used in the engine development department, which is not available as a standard product from domestic manufacturers and would need to be custom-made. Our company has a proven track record with multi-couplings in the casting line, and we have introduced a large lever from an overseas manufacturer that can withstand high pressure as a standard product. Additionally, unlike domestic manufacturers, the manufacturers we work with produce all electric connectors and fluid couplings in-house, allowing for one-stop support in case of any issues, providing peace of mind for implementation. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe connectors for the engine parts assembly device were originally manually plugged and unplugged for electrical and air connections. However, since there were multiple connections for each, this process took a lot of time and sometimes caused electrical connectivity issues at the connector part. As a result, when we aimed to improve productivity in the factory, this issue was raised as an area for improvement, and we consolidated everything to allow for automatic connection and disconnection. As a result, the work time was shortened, leading to an increase in productivity. Additionally, the connectors we introduced use special spring contacts that maintain consistent contact pressure, eliminating connectivity issues, and the staff has reported that "it has become much easier to work with." [Case Study] ■ Issues - We wanted to improve the assembly and inspection line to reduce work time. ■ After Implementation - Work time was reduced, leading to increased productivity. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn the vehicle-mounted radio inspection line, there are connectors for electricity, coaxial, and optical fiber. However, there were no composite connectors combining electricity, coaxial, and optical fiber from domestic manufacturers, so connections were made manually and separately. Therefore, we introduced our composite connector that can integrate electricity, coaxial, and optical fiber. Additionally, by installing a rail and allowing for sliding, we enabled automatic attachment and detachment of all components together, eliminating the need to assign workers to this process and improving productivity. We plan to similarly introduce composite connectors in the inspection lines for car navigation systems and batteries, automating those processes as well. [Case Study] ■Challenge - We want to conduct high-quality inspections efficiently. ■After Implementation - The need to assign workers has been eliminated, resulting in increased productivity. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationUntil the technology of high-current connectors was adopted, it was necessary to significantly increase the area of the contact points for safety against heat generation during current flow and short-circuit currents. By adopting the technology of high-current connectors, the multi-contact points have greatly reduced the contact resistance, allowing for better control of temperature rise. Additionally, they are strong against short-circuit currents and enable high current flow in a compact space. Furthermore, they can accommodate movable states such as sliding and rotating connections, making them indispensable for connections between circuit breakers, switches, and busbars. [Case Study] ■ Challenges - There was a need to significantly increase the area of the contact points for safety against heat generation during current flow and short-circuit currents. ■ After Implementation - The contact resistance has been greatly reduced, allowing for better control of temperature rise. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe were using a common coupling used in the semiconductor industry, but there were liquid leaks during the disconnection of piping during annual equipment maintenance. The end-user, a semiconductor manufacturer, strongly requested that no fluorinated inert liquid be leaked outside during the disconnection of piping even during maintenance. Therefore, we adopted our "no-drip coupling." It allows for one-touch connection and disconnection while maintaining the same or better airtightness as the currently used couplings, eliminating liquid drips to the outside during connection and disconnection. [Case Study] ■ Issues - We received strict demands from customers that liquid drips at the disconnection points of piping are unacceptable. ■ After Implementation - There are no liquid drips to the outside during connection and disconnection. - It has also become possible to prevent human connection errors. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn the semiconductor manufacturing process, there was a disconnection at the power supply points rated at 150-200A in the limited space within the equipment. Conventional connectors were long in length, making the attachment and detachment difficult and cumbersome. To prevent connection failures, a special connector was introduced that uses springs to maintain a constant contact pressure at the connection points. Previously, the production line frequently stopped, but after the introduction of this connector, there have been no issues with power supply failures. [Case Study] ■ Challenges - Large current connectors were causing space constraints. ■ After Implementation - Achieved approximately 30% space savings, allowing for smooth operation even for female and elderly workers with the one-touch design. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn the process of filling canisters for transporting electrolyte, there were instances of electrolyte dripping and a small amount of air mixing in when coupling was attached and detached. Therefore, a coupling that does not allow liquid to drip was introduced. This nearly eliminated losses during attachment and detachment, and concerns about product oxidation and deterioration due to air mixing were alleviated. Additionally, the structure results in about half the pressure loss compared to conventional couplings, which shortened the filling time and led to improved productivity. [Case Study] ■Challenge - Eliminate liquid dripping and air mixing during coupling attachment and detachment. ■After Implementation - No concerns about product oxidation and deterioration due to air mixing. - Filling time was shortened, leading to improved productivity. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn the charging and discharging inspection line, there were no composite connectors combining power and signal from domestic manufacturers, so we were connecting them separately by hand, which was labor-intensive. We were considering ways to improve this situation. Therefore, we introduced our composite connector that can integrate power and sensing into one. Additionally, by installing a rail and enabling sliding, we made it possible to automatically attach and detach everything together. As a result, it became unnecessary to assign workers to this process, leading to increased productivity. [Case Study] ■ Issue - Manual connection of power and sensing connectors separately ■ After Implementation - No need to assign workers, resulting in increased productivity *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document is a collection of successful case studies compiled by Salton Co., Ltd. regarding productivity improvement for automotive-related factories. If you are facing issues such as "connectors and couplings break easily," "I want to shorten the takt time," or "the line stops due to poor electrical contact," this is a must-see for you. 【Examples included in the success case collection】 ■ Press line case ■ Welding line case ■ Injection molding and casting line case ■ Engine test line case ■ Assembly and inspection line case 【Exhibition Information】 ■ Exhibition Name: 5th Nagoya Automotive World ■ Dates: October 26 (Wednesday) to October 28 (Friday), 2022 ■ Venue: Port Messe Nagoya, New No. 1 Exhibition Hall ■ Salton's Booth: NO.8-19 *Please be sure to stop by when you visit the exhibition. *For the productivity improvement success case collection, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Saltone Co., Ltd., we handle tools manufactured by Aicotech. The "compact hydraulic punch driver" without a hose can quickly and easily create rectangular, square, or round holes. We also offer "round hole punches" for mounting holes PG16, M16, M21, M25, M32, M40, M50, M63, M75, and M85. In addition, we have a "punch driver set" that includes a handheld hydraulic punch driver and metric standard hole punches. 【Features】 ■ Highest level of flexibility ■ Multiple cut-out pieces can be divided ■ Suitable for Aicotech cable entry components *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe cable entry system and plate with flame intrusion prevention seal manufactured by Aikotec have been certified for use in railway-related technologies. The expansion (foaming) IFPS flame intrusion prevention seal attached to the back of the component is made of expanding graphite, which swells several times during a fire. This creates a barrier that prevents flames and high temperatures from entering other spaces for as long as possible. 【Features】 ■ Easy assembly ■ High-density wiring capability ■ Easy wiring even with pre-assembled cable terminals ■ Protection rating IP66/NEMA 4X ■ Vibration resistance EN61373 ■ European railway-related standards (flame retardant standards) EN45545-2, EN45545-3, EN1363-1 (E45/EI30) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe handle "Cabinet Accessories" manufactured by Aikotec. The "Ground Plate" is a product that creates airflow, causing ventilation and air conditioning systems to draw in and disperse dust into the cabinet. It can be easily installed even with large connectors, and no additional processing of metal plates is required. In addition, we also offer "Cable Pass-Through Brush Strips" for individual mounting holes found in cabinet bases, cabinets, boxes, panels, server racks, and machine panels. 【Ground Plate Features】 ■ Easy to install and remove ■ Can be easily installed with large connectors ■ No additional processing of metal plates required ■ Modifications can be made without removing cables ■ Everything can be assembled and mounted on cables *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe handle the "Cable Conduit System" manufactured by Aikotech. The conduit fitting "CONFiX FWS," which can be bent at a 90° angle, is designed for the protection of parallel wave cables. It is used inside machines, control panels, and control cabinets, and the flip cover is securely fixed to the mounting box with hinges. Additionally, the wave conduit for cable routing, "CONFiX WS," is used when it is necessary to protect cables from mechanical damage or specific weather conditions. 【Features】 ■ Quick and easy installation ■ Easy maintenance ■ Flexible *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Saltone Co., Ltd., we handle the 'EMC Cable Shield' manufactured by Aikotech. Compared to conventional shield brackets, it achieves a contact area that is up to 50% larger, and the clamping range expands by up to 10%. In the high-frequency domain, the impedance of the SKL shield clamp is kept low, with less than 120Ω at a maximum of 1,000MHz and significantly below 20Ω from 10kHz to 100MHz. 【Features】 ■ Wide clamping range ■ Compatible with thick cable outer diameters even with small product sizes ■ Space-saving design even with all components assembled ■ Available with strain relief ■ Wide contact area with cable shield *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Saltone Co., Ltd., we handle the 'Strain Relief' manufactured by Aikotech. This system is used to bundle and securely fix cables within machines, switch cabinets, boxes, and cable trays. Using standard cable ties, cables can be installed quickly and economically, and the shape of this product is designed to hold the cable ties and cables securely. 【Features】 ■ High cable density ■ Multi-layer installation possible ■ Quick and easy installation ■ Available in various sizes ■ Rich installation methods *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe handle the "Cable Entry Plate" manufactured by Aicotech. It can be assembled quickly and easily, with some parts requiring no tools. It features a high cable density and a compact, space-saving design. Additionally, it adopts many mounting holes based on industrial standard dimensions, sealing cables doubly from both the front and back with protection ratings from IP64 to IP68. We also offer the "Cable Entry Grommet," which provides high flexibility when installing cables. 【Features】 ■ High cable density ■ Quick and easy assembly, with some parts requiring no tools ■ Compact and space-saving design ■ Seals cables doubly from both the front and back with protection ratings from IP64 to IP68 ■ Adopts many mounting holes based on industrial standard dimensions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe product is the "Split Cable Entry Frame" manufactured by Aikotech. The split grommets come in a wide variety of options and can accommodate cables, pipes, and conduits of various diameters. When assembled correctly, the split grommets are securely held within the frame. In addition, we also offer "Split Cable Glands" and "Modular Adapter Systems" for the KT Grommet System. 【Features】 ■ Allows for cable entry, sealing, and strain relief ■ No need to cut and re-terminate pre-terminated cables ■ Wide variety of options available ■ Split grommets are securely held within the frame ■ High level of protection rating is ensured, along with strain relief *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis product is a cable entry product manufactured by Aicotech for railway use. If the IFPS flame intrusion prevention seal is installed and aligned vertically, it has been tested for "E" and "EI." All tested products have successfully achieved certification using just one layer of the flame intrusion prevention seal. 【Features】 ■ Certification for use in railway technology (EN45545-2, EN45545-3, and EN1363-1) ■ Easy assembly ■ High cable density ■ Only one flame intrusion prevention seal is required for the cable entry components *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Schlegel company's "Illuminated Push Button Switch & Emergency Stop Button" is a switch that combines high design quality with dustproof and waterproof functionality. The types of illuminated switches include panel-mounted, ring-type, and selector-type options. The emergency stop button is available in 46 different shapes, including illuminated types with keys. These switches are adopted in a wide range of fields, including machine tools, industrial equipment, and special vehicles. 【Features】 ■ Panel cut dimensions: φ16mm, φ22mm, φ30mm ■ Front bezel height: thinnest 2mm ■ Protection rating: IP65 / IP66 / IP67 / IP69K ★ The "SHORTRON series" with a minimum body length of 16.2mm is a distinctive product. For more details, please feel free to contact us via the [Inquiry Form].
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Salton, a specialized trading company for connectors, we handle a wide range of products that contribute to improved work efficiency while maintaining high quality and low costs. Here, we introduce products for food factories, such as packaging machines and food machinery! 【Lineup and Features】 <Couplings> ■ One-touch connection for increased work efficiency ■ Prevents liquid leakage during attachment and detachment ■ Long lifespan reduces total costs ■ Proven track record in food factories <Connectors> ■ One-touch attachment and detachment for increased work efficiency ■ Waterproof and stainless steel options available ■ Combination of heaters and thermocouples is possible ■ Used in heater power supplies, control panels, food machinery, packaging machines, etc. <Slip Rings> ■ Combination types of electricity + air, heater + thermocouple also available ■ Customization available to match machine specifications ■ Used in packaging machines, filling machines, winding machines, roll heaters, etc. *For more details, please refer to the materials. Feel free to contact us as well.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- We have obtained safety standards from Europe, a leader in safety. - Not only safety, but also highly reliable contact multi-lam bands are used. - With a wide variety of colors and types, we can accommodate various applications. - The cables used are soft, highly flexible cables that are strong against repeated use, such as bending. *For more details, please contact us!*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe handle "waterproof connectors" manufactured by Glenair Italy. The company's "circular multi-pole waterproof connectors" are versatile connectors with a proven track record, designed to withstand harsh operating environments. They are widely praised in various fields such as defense equipment, lighting, medical, aerospace, railways, and production lines, where reliability in cable connections is required. 【Features】 ■ Versatile connectors with a proven track record ■ Ideal for applications requiring reliability in cable connections ■ Applicable in defense equipment, lighting, medical, aerospace, railways, and production lines *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe lightweight and compact New type Safety Limit Switch NM series offers a choice of 5 types of contact elements and 5 types of actuator shapes.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe innovative cable gland manufactured by Aikotech is a cable entry system that allows for easy assembly of cables with connectors thanks to its split-type grommet. It includes a cable entry plate for unprocessed cables and hoses. The grommet can be pressed into the frame, allowing for flexible combinations. No tools are required, making it easy to change to your desired layout. 【Features】 ■ Compliant with RoHS 10 ■ Obtained various certifications including UL, ECOLAB, marine DNV-GL, European railway standard EN45545-3 (E45, EI30), and EN45545-2 (HL3) ■ Strain relief compliant with EN62444 ■ Protection ratings IP54 to IP68 ■ Certified to withstand vibration and shock ■ Easy cable replacement and maintenance *You can view a digest version of the catalog from "Download." For the full version, please apply through "Contact Us."
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe strain relief plate is a plate designed to hold cables or fluid hoses in the notched areas and secure them with standard zip ties. It features a very simple design that achieves both high strain relief functionality and cable organization simultaneously. 【Features】 ■ For cable organization ■ Simple design ■ Screw mounting, 35mm DIN rail ■ EMC strain relief ■ Fabric Velcro-style zip ties *For more details, please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe propose products for important noise countermeasures in control and measurement equipment. It is essential to connect the cable shield to the cabinet ground at a low resistance. This EMC clip allows for easy and efficient grounding to achieve noise countermeasure results. For example, it can be directly attached to an inverter, with proven noise reduction results. In conventional spiral spring methods, it was necessary to push in screws, but this product can be installed simply by stripping the insulation and pushing it into the clamp section. Compared to conventional methods, it can secure a contact area that is up to 50% larger. 【Features】 ■ Can clamp a wide range of outer diameters from 1.5mm to 48mm ■ Installation methods: DIN rail (35 mm H type, 30 mm C type), screws, busbars, for printed circuit boards, inverters ■ Permanent contact with cable shield due to spring design ■ Strain relief function included, PROFINET compatible double strain relief ■ Impedance 10 kHz to 100 MHz; below 20Ω Below 1,000 MHz; below 120Ω
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA connector for rotary connections developed independently by Melcotack. Unlike conventional slip rings, it uses mercury contacts, which eliminates noise generation and allows for connections even with minute signals. Recently, with the automation of manufacturing processes such as FA, the demand for power supply to rotating bodies and signal extraction from rotating bodies has increased. To meet these demands, this series has achieved an immediate delivery system with standard stock and cost reduction. ● Usable with microampere-level minute currents and microvolt-level minute voltages ● Compact design ● Noise-free due to specially encapsulated mercury contacts ● Contacts do not wear out ● Available in 10 types for 1, 2, coaxial 3, 4, 6, 8 poles, and high current applications *For more details, please contact us!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIntroducing the "CombiTac" series of hybrid connectors from Stäubli Electrical Connectors (formerly known as Multi-Contact). By combining various electrical and fluid modules, it is possible to create the optimal configuration tailored to the user's specifications. 【Application Examples】 ● Test consoles for semiconductor testing equipment ● Large computers ● Broadcasting equipment ● Robot control devices ● Various FA (Factory Automation) equipment *For more details, please contact us!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationConnectors in Solar Power Generation Systems 【Features】 - Excellent conductivity performance using a multi-contact method - Safe structure that prevents exposure of conductive parts - Excellent waterproofing - Material with outstanding weather resistance and UV resistance *For more details, please contact us!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is designed to protect anyone from accidental electric shocks. - It has obtained safety standards from Europe, a leader in safety. - Not only is it safe, but it also employs highly reliable contact multi-lam bands. - With a wide variety of colors and types, it can accommodate various applications. - The cables used are soft, highly flexible cables that are strong against repeated use, such as bending. *For more details, please contact us!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe round waterproof multi-pole connectors handled by Salton are the most proven multipurpose connectors today. The ITS series connectors, designed to withstand harsh operating environments, comply with MIL-C-5015 and VG95234 standards. Additionally, the MIL-C-38999 series is widely praised in various fields such as railways, military, lighting, medical, aerospace, and production lines, where reliable cable connections are required. ● Easy to attach and detach with one-touch coupling. ● Resistant to shock and vibration. ● Reliable coupling that can be confirmed by sight, sound, and touch. ● Proven waterproof performance. ● Long lifespan (at least 2000 cycles of attachment and detachment).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe have also obtained certification for our quality assurance system based on ISO9001, and we offer a wide range of products that meet UL and VDE standards. Our product line, which features waterproof structures and EMC-compliant items, has gained support in areas of the FA industry that require environmental resistance, securing a significant share in the applications of FA equipment.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis clip offers a variety of connection methods. - Dolphin clip with an overall insulated cover - Securely grips fine stranded cables, with a safety socket type for wide opening 4mm plug connections - Touch protection structure in accordance with IEC/EN61010-2-031 - The "IF" logo is awarded to exceptionally outstanding product designs at an international competition held once a year.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration