Separate type thickness gauge main unit A456 series 【*Model selection table provided】
A456C
The Elcometer 456 digital thickness gauge, sold in 170 countries and regions worldwide. Please check out the diverse features not found in traditional thickness gauges.
The Elcometer Digital Coating Thickness Gauge 456 is a high-performance thickness gauge designed for manufacturing and quality control. - Excellent measurement accuracy - High-speed readings of over 70 times per minute - A wide range of measurement probes tailored to the target coating thickness and measurement method - Large, easy-to-read color LCD screen - Sturdy design that won't break if dropped - Dustproof and waterproof (IP64) for use even in the rain - Japanese display (supports 30 other languages) (Depending on the model) - Data output to management software via USB cable and BluetoothⓇ - Ability to instantly send measurement data to a PC or mobile device - Scan mode and automatic measurement mode (T only) - Function to notify when measurement values are outside the adjustment range (T only) - Graphing of data within a batch (T only) - Maximum number of readings that can be saved in memory: 2,500 batches, 150,000 points 【Specifications】 - Display: 2.4-inch (6cm) QVGA color TFT display - Battery type: 2 AA batteries - Body dimensions (Height x Width x Depth): 141 x 73 x 37mm - Body weight (including batteries): 161g - Operating temperature: -10 to 50℃
Inquire About This Product
basic information
Elcometer Ltd. was established in the UK in 1947. Since developing the world's first non-destructive coating thickness gauge, we have been selling and servicing coating inspection equipment, including thickness gauges, in over 120 countries and regions worldwide. We have obtained ISO 9000 and ISO 14001 certifications. 〖Applicable Standards〗 AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12, BS 5599, EN 13523-1, IMO MSC.215(82), IMO MSC.244(83), ISO 1461, ISO 19840, ISO 2063, ISO 2178, ISO 2360, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, JIS K 5600-1-7, NF T30-124, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32.
Price range
P3
Delivery Time
Applications/Examples of results
Thickness measurement of coatings is used in various applications such as automotive production lines, bridge inspections, and repairs and inspections of plants. 【Ferromagnetic Metals】 Metals that are attracted to magnets (such as steel, nickel, cobalt, etc.) 【Non-Ferromagnetic Metals】 Metals that are not attracted to magnets (such as gold, silver, copper, aluminum, chromium, titanium, etc.) can have their coating thickness measured. *Note: Diamagnetic materials, such as wood, plastic, acrylic, and glass, cannot be measured if they are the substrate as they cancel out the magnetic field. For more detailed information, please check the 'YouTube' videos on this page. *If Japanese subtitles do not appear: After logging into YouTube, you can set the language to Japanese and the location to Japan from the account icon in the upper right corner of the screen to enable Japanese subtitles. Alternatively, you can select the language from the "Settings" → "Subtitles" option in the lower right corner of the video screen.
Detailed information
-
Model B (A456CFBS, A456CNBS, A456CFNFBS) [Included Items] Main unit, wristband, protective case, two AA batteries, instruction manual
-
Model S (A456CFSS, A456CNBS, A456CFNFSS) 【Included Items】 Main unit, wristband, protective case, screen protector, two AA batteries, instruction manual, USB cable, ElcoMasterⓇ installation CD & QR code
-
Model T (A456CFTS, A456CNTS, A456CFNFTS) 【Included Items】 Main unit, wristband, carrying case, protective case, screen protector, two AA batteries, instruction manual, USB cable, ElcoMasterⓇ installation CD & QR code
Line up(9)
Model number | overview |
---|---|
A456CFBS | This is the main unit for the electromagnetic probe. It can measure the coating thickness on metals (such as steel, nickel, cobalt, etc.) that are attracted to magnets. 【Features】 ・Number of readings that can be saved in memory: Up to the last 5 points |
A456CFSS | This is the main unit for the electromagnetic probe. It can measure the coating thickness on metals (such as steel, nickel, cobalt, etc.) that are attracted to magnets. 【Features】 ・Number of readings that can be saved in memory: 1,500 ・Measurement data can be instantly transmitted to a PC or mobile device. |
A456CFTS | This is the main unit for the electromagnetic probe. It can measure the coating thickness on metals (such as steel, nickel, cobalt, etc.) that are attracted to magnets. 【Features】 ・Number of readings that can be saved in memory: 2,500 batches, 150,000 points ・Measurement data can be instantly transmitted to a PC or mobile device. |
A456CNBS | This is the main unit for the eddy current probe. It can measure the coating thickness on non-magnetic metals (such as gold, silver, copper, aluminum, chromium, titanium, etc.). 【Features】 ・Number of readings that can be saved in memory: Up to the last 5 points |
A456CNSS | This is the main unit for the eddy current probe. It can measure the coating thickness on non-magnetic metals (such as gold, silver, copper, aluminum, chromium, titanium, etc.). 【Features】 ・Number of readings that can be saved in memory: 1,500 ・Measurement data can be instantly transmitted to a PC or mobile device. |
A456CNTS | This is the main unit for the eddy current probe. It can measure the coating thickness on non-magnetic metals (such as gold, silver, copper, aluminum, chromium, titanium, etc.). 【Features】 ・Number of readings that can be saved in memory: 2,500 batches, 150,000 points ・Measurement data can be instantly transmitted to a PC or mobile device. |
A456CFNFBS | This is the main unit for both electromagnetic and eddy current probes. It can measure the coating thickness on both magnetic and non-magnetic metals. *Note: Measurements cannot be taken if the substrate is a diamagnetic material, such as wood, plastic, acrylic, or glass, which cancels out the magnetic field. 【Features】 ・Number of readings that can be saved in memory: Up to the last 5 points |
A456CFNFSS | This is the main unit for both electromagnetic and eddy current probes. It can measure the coating thickness on both magnetic and non-magnetic metals. *Note: Measurements cannot be taken if the substrate is a diamagnetic material, such as wood, plastic, acrylic, or glass, which cancels out the magnetic field. 【Features】 ・Number of readings that can be saved in memory: 1,500 ・Measurement data can be instantly transmitted to a PC or mobile device. |
A456CFNFTS | This is the main unit for both electromagnetic and eddy current probes. It can measure the coating thickness on both magnetic and non-magnetic metals. *Note: Measurements cannot be taken if the substrate is a diamagnetic material, such as wood, plastic, acrylic, or glass, which cancels out the magnetic field. 【Features】 ・Number of readings that can be saved in memory: 2,500 batches, 150,000 points ・Measurement data can be instantly transmitted to a PC or mobile device. |
catalog(2)
Download All CatalogsCompany information
Elcometer, with a specialized team composed of cutting-edge production facilities and elite development engineers in the UK and Europe, has been leading the industry as a frontrunner in the fields of coating inspection, concrete testing, and metal detection. The globally renowned products of Elcometer are available in every region through sales offices in the UK, the US, Singapore, the Netherlands, France, and Germany, as well as through distributors around the world.