Level Sensors - メーカー・企業22社の製品一覧とランキング

更新日: 集計期間:Oct 29, 2025~Nov 25, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

Level Sensorsのメーカー・企業ランキング

更新日: 集計期間:Oct 29, 2025~Nov 25, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

  1. ニチフ Osaka//others
  2. BBKテクノロジーズ ​計装部門 Tokyo//others
  3. 亀岡電子 Kyoto//others
  4. 4 拓和 営業統括本部・本社営業部 Tokyo//Building materials, supplies and fixtures manufacturers
  5. 5 Japan Honeywell GK 本社 Tokyo//others

Level Sensorsの製品ランキング

更新日: 集計期間:Oct 29, 2025~Nov 25, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

  1. Direct-reading liquid level gauge (glass liquid level gauge) BBKテクノロジーズ ​計装部門
  2. Pressure-type water level gauge "CPS-A Series" 拓和 営業統括本部・本社営業部
  3. Tank Gauge | Enraf Servo 954 (JPEX Certified Product) Japan Honeywell GK 本社
  4. 4 Sensing device "Surface Water Detection Rod (Level Sensor)" 住友電工ツールネット 本社
  5. 4 Liquid level sensor CLA for monitoring water levels in remote locations. 亀岡電子

Level Sensorsの製品一覧

16~30 件を表示 / 全 72 件

表示件数

A must-see for electrical and air conditioning wiring contractors! Connectors that can streamline work more than outlet installation.

Introduction of a disconnect connector for multi-package air conditioners that can reduce construction time and costs by over 50%, compliant with Internal Regulations 2022 Edition 3302-2!

We would like to introduce the "Plug Joint Connector," which can be used for disconnection devices for multi-package air conditioners. The Plug Joint Connector can be used as a disconnection device in place of an outlet during the electrical wiring of multi-package air conditioners by combining a plug connector and a terminal block. 【Features】 ■ Complies with the 2022 version of the internal wiring regulations 3302-2 (suitable for disconnection devices) ■ Reduces installation time and costs by over 50% compared to conventional outlets! ■ No need for a junction box ■ Allows for visual confirmation of the wire insertion state, and adopts a double spring structure for the contact area of the wires ■ Easily enables changes from straight connections to branch connections *For more details, please download the PDF or feel free to contact us.

  • Parts and Materials

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Electrical appliance plug joint connector

Joint box according to the Electrical Appliance and Material Safety Law

You can easily wire the F cable by simply connecting the plug connector to the terminal block.

  • Wiring devices

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Usage Example 1] Simply wrap a sensor around the gauge tube to monitor the liquid level.

This is a sensor that can linearly detect the liquid level inside the gauge tube simply by wrapping a film-like electrode around the outside of the gauge tube.

It is an electrode made of flexible transparent film, allowing for completely different uses compared to previous sensors. Have you ever experienced a situation where the contents unexpectedly ran out and the process came to a halt? In addition to linear level display, it is also possible to set up to four control outputs. For more details, please refer to the catalog. *Demo units are available for free rental.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Non-contact liquid level detection with millimeter precision!! Liquid level sensor

A liquid level sensor that can linearly detect the liquid level inside a non-metal container (such as resin) to the millimeter level simply by attaching a film-like electrode from the outside!

This is a capacitive liquid level sensor that can linearly detect the internal liquid level simply by attaching a film-like electrode to the outside of non-metallic containers (made of resin or glass) or gauge tubes. - The electrode is transparent, allowing for visual confirmation. - Since it is a film-like electrode, it can be wrapped around pipes or adhered to curved surfaces. *For more details, please download the catalog or feel free to contact us.*

  • glue

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Non-contact linear detection of liquid level!! Micro-capacity detection specification with a detection length of 40 millimeters.

Mini-sized liquid level sensor ideal for φ10 test tubes. It can be installed on curved or flat surfaces with flexible material.

Mini-sized electrodes of the CLA series! Capable of detecting liquid level ranges from 0 to 40 mm. Can be installed in φ10 dispensers, test tubes, beakers, and viewing windows of tanks.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Heat-resistant and chemical-resistant liquid level sensor specifications *Sample available for loan

Heat resistance temperature of 100℃! While maintaining the functionality of the standard product, the heat and chemical resistance of the electrode part has been improved. *Demo units are available for loan.

The "Heat-Resistant and Chemical-Resistant Liquid Level Sensor" is suitable for managing levels of high temperatures and chemical liquids. While maintaining the functionality of the standard model, the heat resistance and chemical resistance of the electrode section have been improved. FEP is used for the cable, and fluororubber is used for the sealing part. 【Features】 ■ Ideal for managing levels of high temperatures and chemical liquids ■ Heat resistance temperature: 100℃ ■ FEP used for the cable, fluororubber used for the sealing part ■ Protection structure: IP-63 *For more details, please refer to the external link page or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Non-contact linear detection! Capacitive liquid level sensor with micro-capacitance detection specifications.

【Micro-capacity detection detection distance 40 mm】 By simply attaching a film-like sensor to the outside of the container, the liquid level inside the container is linearly detected. It can also be wrapped around pipes.

The "Liquid Level Sensor Micro Capacitance Detection Specification" captures even minute changes of 10pF without missing them. When there are no external influences such as temperature changes, capacitance changes below 10pF can also be measured. It is capable of detecting micro capacitance levels for scientific analysis equipment and the remaining cartridge level in dispensers. 【Features】 ■ Mini size suitable for test tubes and similar applications ■ Capable of measuring capacitance changes below 10pF ■ Micro capacitance level detection for scientific analysis equipment ■ Detection of remaining cartridge level in dispensers ■ Operating temperature range: 0 to 40°C *For more details, please refer to the external link page or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Liquid level sensor pipe-type electrode specifications! Linear detection with a resolution of less than 1 millimeter.

No moving parts! It allows for liquid level detection simply by being immersed in the liquid.

The "Liquid Level Sensor Pipe Type Electrode Specification" allows for level management simply by immersing it in the liquid. Its structure has no moving parts, eliminating issues of false detection due to clogging. It is suitable for slurry liquids such as waste liquids. 【Features】 ■ Structure with no moving parts ■ Eliminates false detection issues due to clogging ■ Ideal for slurry liquids such as waste liquids ■ Usable in metal tanks *For more details, please refer to the external link page or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[CLA Case] Coolant Overflow Management [Bearing Manufacturing]

Using the liquid level sensor 'CLA'! Introducing a case of coolant overflow management! *Sample available for loan.

We would like to introduce a case of coolant overflow management in the bearing manufacturing process using the non-contact liquid level sensor "CLA," which can be installed in various tanks due to its electrodes being suitable for PET film. The bearing manufacturer was using an ultrasonic type but faced challenges due to its high cost and the difficulty of installation. Therefore, they adopted the "CLA pipe type." After implementation, it can be easily installed by tightening with a nut on the top of the tank. With a liquid contact type guaranteed to IP-68, it can manage the liquid level at four points even when directly in contact with the liquid, allowing for control of the device according to the desired liquid level. [Current Issues and Requests] - In the bearing manufacturing process, they are managing the liquid level of the coolant used and overseeing overflow. - They were using an ultrasonic type but faced challenges due to its high cost and the difficulty of installation. *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[CLA Case] Rubber Material in Metal Hopper (Inventory Management) [Powder and Granule Detection]

Using the liquid level sensor "CLA"! Here is a case study on managing the remaining rubber pellets in a metal hopper.

We would like to introduce a case study on managing the remaining amount of rubber material in a metal hopper using the non-contact liquid level sensor "CLA," which can be installed in various tanks due to its electrodes being compatible with PET film. The extrusion molding manufacturer faced issues such as forgetting to visually check the material, leading to it running out and resulting in defective products, which caused damages including repair time. They also experienced malfunctions with ultrasonic sensors, which caused unnecessary line stoppages and reduced productivity. Therefore, they adopted the "CLA." After implementation, by managing the rubber material at any desired position, the sensor emits a signal when the rubber material reaches the set level, automatically stopping the device and notifying with a beacon light, thus preventing the occurrence of defective products due to material shortages. [Current Issues and Requests] - Managing the remaining amount of rubber material in the hopper visually through a window - Forgetting visual checks and mistakes led to the material running out, resulting in defective products and damages including repair time. - Ultrasonic sensors malfunctioned, causing unnecessary line stoppages and reducing productivity. *For more details, please refer to the PDF document or feel free to contact us.*

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[CLA Case] Liquid Tank (Dilute Sulfuric Acid) Level Detection [Semiconductor Equipment Related]

Using the liquid level sensor "CLA"! It can detect the liquid level position and output it with an analog signal, allowing for linear liquid level management!

We would like to introduce a case of level detection in a chemical tank using the non-contact liquid level sensor "CLA," which can be installed in various tanks due to its electrodes being suitable for PET film. (Detection substance: dilute sulfuric acid) For companies related to semiconductor equipment, changing the liquid level management position requires the hassle of reattaching sensors. They faced the challenge of not knowing the liquid level position due to point-based liquid level management. Therefore, they adopted the "CLA." As a result, by allowing the setting of four detection points for the liquid level, there is no need to change the sensor position. Additionally, with analog output, the liquid level position can be detected and output, enabling linear liquid level management. 【Current Issues and Requests】 ■ Currently, four capacitive sensors are installed for liquid level management. ■ The management of the liquid level changes depending on the liquid and operating conditions. ■ We want to monitor the liquid level linearly to know its position. ■ If we want to change the liquid level management position, it requires the hassle of reattaching sensors. ■ Due to point-based liquid level management, we do not know the position of the liquid level. *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Liquid Level Sensor Example] Detection of Remaining Epoxy Resin [Carbon Fiber]

Using the liquid level sensor "CLA"! Here is a case study on detecting the remaining amount of epoxy resin. *Sample units are available for loan.

We would like to introduce a case study on detecting the remaining amount of epoxy resin using the non-contact liquid level sensor "CLA," which can be installed in various tanks due to its electrode being made of PET film. A carbon fiber company faced challenges in managing the liquid volume in their epoxy resin tank. The current sensor (guide pulse method) could not detect when the liquid volume was low, and the accuracy of liquid level management was poor, with a precision of 3 to 5 mm against the desired liquid level of ±1 mm. Therefore, they adopted the liquid level sensor "CLA-D10P40." As a result, they were able to detect the liquid level with an accuracy of ±1 mm and manage the liquid level by installing the sensor at the desired position, even when the liquid volume was low. 【Current Challenges and Requests】 - Challenges arose in managing the liquid volume in the epoxy resin tank. - The current sensor (guide pulse method) cannot detect when the liquid volume is low. - The accuracy of liquid level management is poor, with a precision of 3 to 5 mm against the desired liquid level of ±1 mm. *For more details, please refer to the PDF document or feel free to contact us.*

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[CLA Case] Hydraulic Cylinder Oil Level Management [Automotive Parts and Machinery Industry]

Using the liquid level sensor "CLA"! We will introduce examples of oil level management for hydraulic cylinders. *Sample units are available for loan.

We would like to introduce a customized case of the non-contact liquid level sensor "CLA," which can be installed in various tanks due to its electrodes being made of PET film. The oil level management of hydraulic cylinders is currently done visually, but the sensors are located on the back side of the equipment, making it difficult to check without going around to the back, as they are hidden by the equipment and there are many of them to confirm. Therefore, we installed the liquid level sensor "CLA-D10P40." With an accuracy of ±1mm for the desired liquid level, it can detect the liquid level, allowing for management by installing it at the position of the liquid level to be monitored, even when the liquid volume is low. 【Current Issues and Requests】 - The oil level management of hydraulic cylinders is done visually, but the sensors are located on the back side of the equipment: - Cannot check without going around to the back - Hidden by the equipment - Difficult to confirm due to the large number - We want to monitor with sensors and raise the management level - Other sensors are not easy to install *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

CLS (Capacitance Type Liquid Level Switch Multi-Point Output Type)

We can propose the automation and monitoring system in the factory using our level sensor products!

Kameoka Electronics Co., Ltd. provides integrated production services tailored to customer needs, covering product development design, parts procurement, production planning, manufacturing (including board assembly), and shipping for various sensors. Additionally, we support improvement proposals for equipment using level sensors. If you have applications where you want to avoid contact with the target object or require non-destructive testing, please feel free to consult us. ■ Case Study: Example from a printing peripheral equipment manufacturer Before implementation, there were concerns about sensor degradation with contact-type sensors, and it was difficult to predict failure timing. By installing a non-contact CLS on the outside of the tank, we achieved non-contact liquid level management for defoamer. *We also have examples of solving mounting issues through modifications of standard electrodes. For more details, please refer to the PDF materials or feel free to contact us.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Remote liquid level monitoring Liquid level sensor CLA

Next-level liquid volume management! Why not start monitoring liquid levels with IoT?

Proposal for a product that allows constant monitoring of liquid levels in tanks located away from the office【Part 2】 【Example of collaboration with communication devices】 By combining our liquid level sensor CLA, which can monitor the water level inside tanks (excluding metal tanks) simply by being attached to the outside, with an analog wireless converter manufactured by our partner, Kurohne Co., Ltd., it is possible to monitor the liquid levels of remote tanks using a computer in the office. The analog wireless converter can be powered by batteries or via USB (DC5V). In the case of USB power (DC5V), it can also supply DC24V for the liquid level sensor CLA from the analog wireless converter, so if you have a conversion adapter that changes AC100V to DC5V, you can operate both the liquid level sensor CLA and the analog wireless converter with an AC100V power source. This solution helps address challenges related to liquid level monitoring management, such as the hassle of having to patrol multiple tanks and the time required for patrolling due to labor shortages. The above is just one example. Regarding communication devices, we collaborate with multiple companies, so we can propose various collaboration patterns with communication devices to suit your specifications.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Level Sensorsに関連する検索キーワード