pump Product List and Ranking from 339 Manufacturers, Suppliers and Companies | IPROS

Last Updated: Aggregation Period:Mar 11, 2026~Apr 07, 2026
This ranking is based on the number of page views on our site.

pump Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Mar 11, 2026~Apr 07, 2026
This ranking is based on the number of page views on our site.

  1. 岡三機工 Osaka//Building materials, supplies and fixtures manufacturers
  2. null/null
  3. 日本スプライススリーブ 本社 Tokyo//Building materials, supplies and fixtures manufacturers
  4. 4 横田製作所 Hiroshima//others
  5. 5 川本製作所 Aichi//others

pump Product ranking

Last Updated: Aggregation Period:Mar 11, 2026~Apr 07, 2026
This ranking is based on the number of page views on our site.

  1. Water Heat Source Heat Pump "PMAC System" NIPPON PMAC Co., Ltd.
  2. One-handed portable AC 100V power mortar pump OKP-07M 岡三機工
  3. Mortar-filled rebar joint "Slim Sleeve" 日本スプライススリーブ 本社
  4. 4 Fire pump "Safety Ace Series KTY type" 川本製作所
  5. 5 Inverter Variable Speed Grout Injection [Mortar Pump] OKG-35E 岡三機工

pump Product List

61~90 item / All 1869 items

Displayed results

[Case Study] Transport of a liquid that hardens upon exposure to air

Solve the issue of "hardeners sticking due to exposure to air, causing pump failures" at the foundry manufacturer!

The request from the casting manufacturer was to create sand molds for casting by adding a hardener to the sand during the manufacturing process. However, there was a challenge where the hardener leaked from the pump's shaft seal, came into contact with air, and solidified, causing the pump to fail. The hardener was supplied using a gear pump, and the injection amount was controlled by an electromagnetic valve. For the solution to this issue, please download and refer to the PDF materials. 【Customer's Challenge】 ■ The hardener leaking from the pump's shaft seal comes into contact with air and solidifies, causing the pump to fail. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Automation of the 4-liquid mixing process improves quality.

Solving issues such as "variability in concentration"! A case where automation improved the process and quality.

The request from the steel manufacturer was to mix four types of liquids to apply a coating agent on the surface of electrical steel sheets and supply it to a roll coater. However, each liquid was transferred to a tank using a hydraulic diaphragm pump, and after stirring and mixing, it was supplied to the roll coater. As a result, there were issues such as "variations in concentration due to uneven stirring in the tank" and "operators having to constantly monitor the concentration in the stirring tank and manually adjust the four pumps." For solutions to these issues, please download and view the PDF document. [Customer's Issues] ■ Variations in concentration due to uneven stirring in the tank ■ Operators must constantly monitor the concentration in the stirring tank and manually adjust the four pumps *For more details, please refer to the PDF document or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Reducing Liquid Waste with Spray Application of Release Agent

Case studies of solving challenges such as "wanting to eliminate waste and reduce costs" for rubber product manufacturers.

In the tire manufacturing process, rubber product manufacturers spray release agents using spray guns and have been using air-driven pumps for liquid supply. As a result, there were challenges such as, "The air-driven pump causes fluctuations in flow rate due to pressure variations on the discharge side, which can lead to excessive spraying," and "Release agents are expensive, so we want to eliminate waste and reduce costs." For solutions to these challenges, please download and view the PDF materials. [Customer Challenges] ■ The air-driven pump causes fluctuations in flow rate due to pressure variations on the discharge side, which can lead to excessive spraying. ■ Release agents are expensive, so we want to eliminate waste and reduce costs. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Automation of flow management from manual weighing to flow measurement using a flow meter.

Automate flow management with flow meters! Solve issues such as "unable to use flow meters" and "unstable flow"!

In a paper manufacturing company that transfers and injects dyes in the production process, a plunger pump was traditionally used. As a result, there were challenges such as "the existing pump has pulsation, so a flow meter cannot be used," "overfeed phenomena occur, causing flow to be unstable," and "there may be response delays (discharge delays and liquid dripping) when starting and stopping the pump." For solutions to these challenges, please download and view the PDF materials. 【Customer Challenges】 ■ The existing pump has pulsation, so a flow meter cannot be used. ■ Measurements are taken manually with a graduated cylinder, and the pump's discharge amount is adjusted manually. ■ Due to long-distance piping and small pipe diameter, overfeed phenomena occur, causing flow to be unstable. ■ There may be response delays when starting and stopping the pump. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Safely Diluting Sodium Hydroxide (Caustic Soda)

Solving issues such as the risk of liquid splashing! A case of safely diluting sodium hydroxide.

A chemical manufacturer requested to safely dilute sodium hydroxide (caustic soda) from a concentration of 48% to 25%. However, there were concerns that "there is a risk of intense heat generation during dilution, causing the liquid to splatter" and "there is a risk of serious injury if the liquid comes into contact with the human body." For solutions to these issues, please download and refer to the PDF materials. [Customer's Issues] ■ There is a risk of intense heat generation during dilution, causing the liquid to splatter. ■ There is a risk of serious injury if the liquid comes into contact with the human body. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Continuous Transfer of Color Toner Pigments Without Wear

We will solve your request to supply raw materials to the disperser on the color toner manufacturing line! Here is a case study from an OA equipment manufacturer.

The request from the OA machine manufacturer was to supply raw materials to the disperser in the color toner manufacturing line. However, we faced several challenges after trying various pumps, such as "the air-driven pump has too high a flow rate" and "even with a damper, we couldn't suppress the pulsation, resulting in intermittent flow." For solutions to the challenges and requests, please download and view the PDF materials. 【Customer's Challenges and Requests】 ■ The air-driven pump has too high a flow rate. ■ Even with a damper, we couldn't suppress the pulsation, resulting in intermittent flow. ■ The tube pump not only has pulsation, but the tube also wears out due to the slurry liquid, leading to rubber debris contamination. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Flow-Proportional Injection in Ballast Water Treatment Systems

Solving the request to inject chemicals into seawater with a ballast water treatment system installed on ships! Introducing case studies from water treatment equipment manufacturers.

The request from the manufacturer of water treatment equipment was for a ballast water treatment system to be installed on ships, with the desire to inject chemicals into seawater. However, there were challenges such as the need for "high reliability to strictly adhere to the discharge standards specified by the treaty" and "the treated water must be discharged directly into the sea, so it must be treated reliably." Please download the PDF document to see the solutions to the challenges and requests. 【Customer's Challenges and Requests】 ■ High reliability is required to strictly adhere to the discharge standards specified by the treaty. ■ Since there is a large variation in treatment volume, we want a wide control range for the chemical injection amount. ■ The treated water must be discharged directly into the sea, so it must be treated reliably. ■ Due to limited space on the ship, we want a compact system. ■ To reduce maintenance burden, we want robust and simple piping. *For more details, please refer to the PDF document or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Stable Injection of Chelating Agents to Prevent Heavy Metal Leaching

Solving issues such as "looseness and leakage" when using plunger pumps! Introducing case studies from local governments (wastewater treatment plants).

The local government (sewage treatment plant) was using a plunger pump to add a chelating agent (ferrous sulfate solution) to prevent the leaching of heavy metals contained in the incineration ash after incinerating sludge at the sewage treatment plant. However, there were issues such as "the piping vibrated due to the pump's pulsation, causing loosening and leaks" and "the pump had run dry and malfunctioned when the chemical tank was empty." For solutions to these issues and requests, please download and view the PDF materials. 【Customer's Issues and Requests】 ■ The piping vibrated due to the pump's pulsation, causing loosening and leaks. ■ The pump had run dry and malfunctioned when the chemical tank was empty. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Dividing the raw material liquid into six directions and injecting it into the mixing tank.

We have resolved the request to inject the same amount of liquid from six locations at the top of the mixing tank in the manufacturing process of dental materials! Here is a case study from a dental materials manufacturer.

The dental materials manufacturer requested to inject the same amount of liquid from six locations at the top of the mixing tank during the manufacturing process of dental materials. However, there was a challenge in finding a manufacturer that could produce a six-channel diaphragm pump. Please download the PDF document to view the solution to the challenge and request. 【Customer's Challenge/Request】 ■ Unable to find a manufacturer that could produce a six-channel diaphragm pump. *For more details, please refer to the PDF document or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Safe Long-Distance Transport of Concentrated Sulfuric Acid (98%)

Solving issues such as 'damage caused by corrosion from sulfuric acid without realizing it'! Introducing a case study from a steel manufacturer.

The steel manufacturer was using a hydraulic diaphragm pump to transport 98% sulfuric acid over long distances within the steelworks. However, there were challenges such as "damage that can occur unknowingly due to corrosion from sulfuric acid" and "the need for pump overhauls every three years, incurring costs each time." Please download the PDF document to see the solutions to the challenges and requests. 【Customer's Challenges and Requests】 ■ An accumulator was installed to eliminate pulsation, but it can be damaged unknowingly due to corrosion from sulfuric acid. ■ Due to long-distance piping, a high-pressure pump is used considering pressure loss, and continuing operation without the accumulator functioning poses a risk of pipe damage, which is very dangerous. ■ Pump overhauls are required every three years, incurring costs each time. *For more details, please refer to the PDF document or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Supporting Long-Term Experiments of Culture Medium Injection into Columns for Over One Month

Easy changes to flow rates and calibration operations! Introduction of cases adopted by national universities.

At the National University (Graduate School of Environmental and Life Science), a culture solution containing nutrients that serve as food for microorganisms was being pumped into a column filled with soil samples. It was necessary to collect data for more than a month, and it was ideal for the flow rate to remain constant during that time. For solutions to the issues and requests, please download and view the PDF materials. 【Customer's Issues and Requests】 ■ Looking for a pump with minimal fluctuations in flow rate and pressure to collect data under consistent conditions. ■ It is ideal for the flow rate to remain constant for more than a month while collecting data. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Balancing Stable Operations During Normal Times and Measures Against Sudden Heavy Rainfall

Control of stroke length is not performed! Introduction of a case where gas lock no longer occurs even in low flow regions.

The local government (sewage treatment plant) measured the flow rate of the water flowing through the channel after sedimentation and filtration, and injected the necessary amount of sodium hypochlorite. Using a diaphragm pump, they implemented dual control of stroke length and rotation speed; however, there was a problem where "when operating with a reduced stroke length during low processing volumes, injection failures due to gas lock occurred." For solutions to the issues and requests, please download and view the PDF materials. [Customer's Issues and Requests] ■ When operating with a reduced stroke length during low processing volumes, injection failures due to gas lock (air entrainment) occur. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Solving the Problem of Frequent Impeller Replacement

Introduction of a case where the pump efficiency is good and cavitation due to turbulence is less likely to occur!

At the paper manufacturing company, we are transporting fillers to be added to the paper in the process of turning pulp into paper. Traditionally, we have been using metal spiral pumps, but there has been a problem where "the stainless steel impellers are quickly eroded and need to be replaced every three months." For solutions to the challenges and requests, please download and view the PDF document. 【Customer's Challenges and Requests】 ■ The filler is a mineral-based slurry with high hardness, causing the stainless steel impellers to erode quickly, requiring replacement every three months. ■ We have tried processing to increase the hardness of the impellers, but no improvements have been observed. *For more details, please refer to the PDF document or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Transporting the flammable chemical butyllithium under high pressure

We have become able to transport liquids safely without leakage! Here is an introduction to a case where we were adopted by a national university.

At the National University (Graduate School of Engineering), a microreactor is used to supply small amounts of chemical solutions for organic synthesis experiments. "There is a need for a discharge pressure of 10 MPa to inject liquid into the narrow flow path." "There are challenges such as the need for safety measures in case of pipe blockage, but it is not possible to attach branch piping like safety valves to the pipes." For solutions to the challenges and requests, please download and view the PDF materials. 【Customer's Challenges and Requests】 ■ To strictly control the reaction, the liquid must be delivered in a continuous, constant flow without pulsation. ■ The transfer liquid is butyllithium, which ignites upon exposure to air, so it must not leak. ■ A discharge pressure of 10 MPa is required to inject liquid into the narrow flow path. ■ Safety measures are necessary in case of pipe blockage, but it is not possible to attach branch piping like safety valves to the pipes. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Improving Quality and Cleanability in the Pigment Dispersion Process

Introduction of a case where high-viscosity liquids were delivered with high precision without a drop in flow rate!

The pigment manufacturer uses a bead mill for the dispersion of materials in the pigment manufacturing process. Due to the viscosity of some liquids being around 5000 mPa·s, a vane pump suitable for high-viscosity liquids was used. However, the wear of the pump parts led to contamination in the liquid, affecting the quality of the ink. For solutions to the challenges and requests, please download and view the PDF materials. [Customer's Challenges and Requests] ■ The wear of the pump parts led to contamination in the liquid, affecting the quality of the ink. ■ Due to frequent liquid changes in small-batch production, a pump with high washability is desired. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Supporting Addition, Mixing, and Filtration in the Beer Production Process

We respond to requests such as 'I want to accurately add the specified amount!' Here are examples from sake manufacturers.

At the sake brewing manufacturer, during the beer production process, auxiliary materials, yeast, and filtration aids were added using pumps, and inline mixing was performed with static mixers. We received requests such as "We want to add the specified amount accurately" and "We want to use pumps that do not carry the risk of foreign matter contamination due to wear of parts." For solutions to the challenges and requests, please download and view the PDF materials. 【Customer's Challenges and Requests】 ■ We want to add the specified amount accurately. ■ We want to use pumps that do not carry the risk of foreign matter contamination due to wear of parts. ■ Sanitary pumps generally have expensive parts, but we want to keep running costs as low as possible. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Simple and Accurate Micro Dropping in Synthesis Experiments

We will introduce examples that solve issues such as "syringes are made of glass, making them fragile and difficult to handle."

In the urethane synthesis experiment, isocyanate is dripped into alcohol at a rate of 1 mL/min. Traditionally, we have been using a micro-syringe pump, but there have been issues such as "there are few syringes that are compatible with Japanese-made syringes because the pump is made overseas." For solutions to the challenges and requests, please download and view the PDF materials. 【Customer's Challenges and Requests】 ■ There are few syringes that are compatible with Japanese-made syringes because the pump is made overseas. ■ The syringes are made of glass, making them prone to breakage and difficult to handle. ■ Some researchers are dripping manually because preparing the pump is cumbersome, but it is difficult to drip at a constant speed. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Significant Reduction in Maintenance Man-Hours and Downtime

Solving issues such as 'parts wear out with use'! Introducing a case study from a food packaging manufacturer.

The food packaging manufacturer uses pumps in the process of applying adhesive to packaging films. Traditionally, they have been using precision gear pumps, but there have been issues such as "the need for pump maintenance every three months, which requires stopping the line for a day each time." For solutions to the challenges and requests, please download and view the PDF materials. [Customer's Challenges and Requests] ■ The pump has a structure where multiple gears mesh to send liquid, causing parts to wear out over time. ■ Pump maintenance is required every three months, necessitating a one-day line stoppage each time. ■ Tasks such as adjusting gear clearance require specialized skills, leading to high outsourcing costs. *For more details, please refer to the PDF materials or feel free to contact us.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Integrated synchronous pump picosecond OPO optimal for micro-spectroscopy.

Ultra-stable picosecond wavelength-tunable laser (OPO) designed for CARS, SRS microscopy, and coherent RAMAN microspectroscopy applications.

The picoEmerald from the German company APE automatically overlaps extremely short pulse trains both temporally and spatially, providing three outputs: 1064 nm laser output, OPO signal, and OPO idler. It ensures reliable pulse synchronization and allows for hands-free operation with fully automated control. It delivers high-quality picosecond pulses, making it ideal for CARS and microscopic spectroscopy. In addition to CARS and SRS, it is also perfect for applications in stimulated Raman microscopic spectroscopy, multiphoton fluorescence, and multimodal imaging, including second harmonic generation. It offers wavelength tunability from 700 to 1950 nm, and even with changes, the two-color light pulses completely overlap both temporally and spatially.

  • others
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Electric drum pump for kerosene and light oil / M58EPA-ATN

Electric drum pump for kerosene and light oil (with automatic shut-off nozzle) / Model number M58EPA-ATN

Measuring and stopping are standard! Cost reduction through usage management! Pursuing reasonable prices The long-awaited flow meter integrated drum pump ● Flow meter integrated You can choose from three types with flow meters: M58EPA-ATN, M58EPA-ATNK24, and M58EPA-M33-ATN, depending on your application. There is also a type without a flow meter, allowing for economical use of kerosene drum pumps. ● Electric type for kerosene and light oil with auto-stop gun preset Automatically stops discharge when the liquid is full This prevents overflow. ● Improvement in liquid management With the flow meter, you can see the flow rate at a glance, eliminating waste and leading to cost reduction. ● Continuous operation possible With electric 100V, it can be operated continuously, making it usable anywhere. This also increases work efficiency.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Electric solvent SUS chemical pump / M58CEM1-20SUSA

It is ideal for transferring and dispensing solvents and chemicals with a viscosity of 100 cP or less. It is electric and can operate continuously.

M58CEM1-20SUSA (for solvent use) M58CEM1-V20SUSA (for solvent use / with ball valve) M58CEM1-N20SUSA (for solvent use / with gun nozzle) ● Continuous operation possible ● Lightweight and compact body ● Inexpensive

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Food Processing Plant

Suppressing the growth of algae in the cooling tower! The evaporation residue has also decreased from 952 mg/l to 499 mg/l.

In a food processing factory that is 11 years old, a large amount of chlorine was used to suppress the growth of slime caused by bacteria in the cooling tower. To reduce the amount of chlorine being used, an "NMR Pipe Protector" was installed. Even with the chlorine dosage reduced to one-third, the growth of algae in the cooling tower could still be suppressed. Additionally, the number of general bacteria (microorganisms) decreased from 640 to 270, and the color value, which increases due to organic matter contamination, was significantly reduced from 8 degrees to 3 degrees, within the water quality standard. 【Introduction Overview】 ■ Location: Shizuoka Prefecture ■ Building Overview: 11 years old, factory ■ Water Supply Method: Pump pressurization method ■ Installation Date: October 30, 1998 ■ Installed Piping/Number of Installations: Well water pump primary side (HI-VP 40mm)/PT-50DS x 1 unit *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sampling Pump Gillian 10i/12

A compact and lightweight sampling pump that boasts excellent pressure load characteristics. It can be used for asbestos dispersion prevention measures.

It is suitable for measuring airborne asbestos and can also measure atmospheric concentration at site boundaries (construction plot boundaries), etc. It is a compact and lightweight model with a body weight of only 580 g. The pressure characteristics at a suction rate of 5 L/min are high, with the Gilian 10i at 10.0 kPa and the Gilian 12 at 14.2 kPa. It can measure with a suction flow rate of 5 L/min for 120 minutes. It comes with various measurement and display functions, including alert displays to prevent the capture of faulty data and a fault function that automatically stops suction.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Small Dry Vacuum Pump KM

Orion Machinery / Vacuum Pump. Adopts a free rotor system that does not require side adjustments for precision air conditioning.

■Adopts a free rotor system that does not require side adjustments. ■Easy maintenance. ■Oil-free operation, so it does not contaminate the work environment or products with oil. ■Can be directly connected to rubber or vinyl hoses.

  • Air compressors, blowers and pumps
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

KRF Series Small Standard Dry Vacuum Pump

Orion Machinery / Vacuum Pump. Safe design, environmentally friendly, and long lifespan realized. Environmentally friendly next-generation pump.

■Safe design, environmentally friendly, CE marking compliant. ■Low operating noise, reduction of 2-5 dB (compared to conventional models) due to quiet design. ■20% increase in lifespan (compared to conventional models) due to the adoption of new material blades. ■Compliant with RoHS directive standards.

  • Air compressors, blowers and pumps
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Combination Dry Vacuum Pump CBX Series

Orion Machinery/Vacuum Pump. 2-cylinder, 2-function (vacuum pump and blower in parallel) system.

■The 2-cylinder 2-function (vacuum pump and blower in parallel) system allows for independent use as a vacuum source with a vacuum level of 60 kPa or lower and an air source with an exhaust pressure of 60 kPa or lower simultaneously. ■Compared to conventional combination pumps, it is compact and lightweight (compared to our products). ■Additionally, it is easy to handle.

  • Air compressors, blowers and pumps
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inline single-stage vortex pump TP

Grundfos pump. A high-efficiency inline pump designed with various applications in mind. It boasts a wide range of products.

■Grundfos TP and TPE vertical inline pumps can be used for various applications. All pumps are single-stage inline centrifugal pumps equipped with standard motors and mechanical shaft seals. These are close-coupled pumps where the pump and motor are independent units. Compared to similar canned rotor pumps, they have the advantage of being unaffected by impurities in the conveyed liquid. ■There are two models of vertical inline pumps. We offer a wide range of special product options for each model. 【TP Pump】 This pump is characterized by excellent reliability and high efficiency. For models with 7.5KW 4P and 11KW 2P or higher, a quiet IE2 motor with high-efficiency operation is standard. The pump body of the TP pump is coated with electrodeposition, ensuring excellent corrosion resistance. 【TPE Pump】 The main difference between the TP and TPE pumps is the motor. The TPE motor has a built-in frequency converter, allowing for different control methods to be applied. The TPE pump saves energy and enhances comfort.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Direct-acting diaphragm suction pump NBG

Grundfos pumps. Used for applications such as water supply, industrial boosting, industrial liquid transfer, HVAC (heating, ventilation, air conditioning), and irrigation.

■Single suction pumps are used in applications such as water supply, industrial boosting, industrial liquid transfer, HVAC (heating, ventilation, air conditioning), and irrigation. ■Single suction pumps are versatile pumps that are highly reliable, cost-effective, and capable of handling various applications, primarily used in five areas: water supply, industrial boosting, industrial liquid transport, HVAC (heating, ventilation, air conditioning), and irrigation. ■NB/NBG pumps are non-self-priming single-stage centrifugal volute pumps equipped with a shaft-side suction inlet, a top discharge outlet, and a horizontal shaft, designed as direct-coupled pumps that comply with the main dimensions of EN733 or ISO2858 standards.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Deep Well Water Pump Inverter Automatic Control Unit SPCP

Grundfos pump. Stable discharge pressure and energy saving through constant water supply with inverter operation.

The deep well water pump inverter automatic operation unit SPCP provides stable discharge pressure and energy savings through constant water supply with inverter operation, as well as the advantage of reduced installation space. Additionally, the flow switch quickly detects low flow rates (below 10L/min) and stops operation, preventing unnecessary running. The pump and motor are made of stainless steel (SUS304), and the piping of the automatic operation unit and the above-ground part (with curved pipe well cover) are also standardly made of stainless cast iron (SCS13), offering excellent weather resistance and corrosion resistance.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Titanium Vertical Multistage Spiral Pump CRT

Grundfos pump.

All major parts of the pump are made from titanium, which is lightweight, strong, and boasts extremely high corrosion resistance. It is suitable for applications involving the transfer and pressurization of highly corrosive liquids, including seawater.

  • pump
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration