Numerous construction achievements and know-how! Completely shut out leaks outside the tank.
We would like to introduce our "Lining Construction for Solvent Tanks." We apply materials that can withstand various solvents to the entire inner surface of the tank, completely shutting out any leakage of the tank contents to the outside. Lining for hydrocarbons such as toluene and xylene, as well as alcohols and industrial gasoline, is also possible. We apply the extensive construction experience and know-how we have cultivated through tank lining to solvent tanks as well. Please feel free to consult us when needed. 【Items that can be lined】 ■ Hydrocarbons ■ Alcohols ■ Aromatic and ester compounds ■ Ketones ■ Ether glycol compounds, etc. *For more details, please refer to the PDF document or feel free to contact us.
Inquire About This Product
basic information
For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
catalog(1)
Download All CatalogsCompany information
Currently, environmental destruction due to global warming is progressing on a global scale. Amidst this, in our country, leakage accidents have occurred at aging hazardous material storage facilities in various regions, and environmental destruction caused by soil contamination has become a serious social issue. Additionally, due to amendments to the Fire Service Act regarding underground storage tanks, leakage prevention measures have been made mandatory. The government is also taking proactive measures, such as partially subsidizing soil contamination environmental conservation projects at fueling facilities, but soil conservation measures must be addressed as a problem that requires cooperation between the public and private sectors. Our company is enhancing related products for leakage prevention measures, focusing on underground tanks and piping, so that owners of hazardous material storage facilities can operate their businesses with peace of mind. We hope to be of assistance to everyone with our many years of rich experience and reliable technology. ● FRP lining construction for underground tanks, etc. (Patent No. 3594183) ● Piping lining ● Construction of solvent tanks (Patent application 2014-185015, Utility model application 2015-003503) ● Steel tank inner surface FRP double-shell structure [with leakage detection device] (Patent application Japan 2012-256961, Utility model No. 3196696) (Patent Australia No. 2012-101365)