Measures to prevent red water and leaks in the water supply piping of Legend Hotel Saigon.
Case study of introducing NMR pipe protectors for preventing red rust and extending the lifespan of hotel water supply piping.
The Legend Hotel Saigon is a building that is 7 years old and used galvanized steel pipes (SGP) for its water supply piping. Due to the high sulfur content in the water supplied by Ho Chi Minh City, red rust corrosion in the hotel's water supply pipes progressed very quickly, resulting in red water coming from the faucets in guest rooms within 6 to 7 years after completion. There were also concerns about potential leaks in the future. To address the red water issue caused by red rust in the water supply pipes, a pipe replacement was planned, but it was costly and required a water outage, which would necessitate halting hotel operations. Therefore, a rust prevention and pipe longevity device called the "NMR Pipe Protector," which does not require a water outage, was installed by a major Japanese general contractor. Before the installation of the NMR Pipe Protector, very dark red water due to red rust was coming from the faucets, but 1.5 months after the installation, the water became almost clear, and complaints from the hotel ceased. The NMR Pipe Protector has stopped the progression of new red rust, and it has been proven that the existing red rust in the pipes has transformed into inert black rust that does not dissolve in water.
Inquire About This Product
basic information
**Introduction Overview** ■Building Name: Legend Hotel Saigon ■Location: Vietnam ■Building Overview: 7 years old, 17 stories, 282 rooms ■Installation Date: July 31, 2008 ■Installed Piping/Number of Units: High water tank secondary side water supply piping (SGP pipe 200mm)/PT-200DS×1 unit High-rise system booster pump primary side water supply piping (SGP pipe 100mm)/PT-100DS×1 unit The NMR pipe protector has proven to stop the progression of new red rust, and the existing red rust within the piping has transformed into inert black rust that does not dissolve in water. If the NMR pipe protector continues to be used, all red rust in the piping will change to black rust, thereby preventing external corrosion and extending the lifespan of this water supply piping until the end of the hotel's building life. ■■■■■ Japan System Planning Co., Ltd. ■■■■■ Toll-Free Number: 0120-320-390 <Free Material Request/Inquiries> https://www.jspkk.co.jp/jp/contact/ *For more details, please refer to the PDF materials or feel free to contact us.*
Price range
Delivery Time
Applications/Examples of results
Over 4,200 installations!
catalog(13)
Download All Catalogs



Company information
~Extending the lifespan of old piping~ "NMR Pipe Protector" Cumulative installation record surpassing 4,300 buildings! (As of March 2022) Among them, over 3,000 installations in condominiums. = Domestic Achievements = New Chitose Airport Domestic Terminal, JR Sapporo Station (JR Tower Building), Imperial Theatre Building (Tokyo Marunouchi), Yaesu Exit Hall, Famous Bookstore Building (Shinjuku), Hotel Toyokaku (Kyoto), Hotel Serve Shibuya, Care House Shirasagi (Saitama), Kawanishi Private Kushi Elementary School, Food Processing Factory, Major Automobile Manufacturer Factory (Fukuoka Prefecture), Kumamoto Red Cross Hospital, etc. = International Achievements = Buckingham Palace, London City Hall, British Museum, BBC, Christ's College, University of Cambridge, Royal Bank of Scotland, Harrods Department Store, Royal Garden Hotel London, UK Parliament, etc. ★ Featured in the Media "NMR Pipe Protector" ★ Selected as one of the top 10 rust prevention technologies in the world in 2020 and introduced in a U.S. magazine! Case studies and customer testimonials have been featured in many media outlets, including TV Tokyo's "World Business Satellite (WBS)," TOKYO MX's "Corporate Spirit," and specialized newspapers "Condominium Management News" and "Air Conditioning Times."