We conducted visual inspections and internal observations using X-ray CT on normal products and degraded products!
We would like to introduce the internal condition of aluminum electrolytic capacitors that have malfunctioned due to aging degradation, which was confirmed using X-ray CT. In degraded products, the internal pressure rises due to gas generated from the decomposition of the electrolyte, and as degradation progresses, there is a risk that the electrolyte may spout out due to the opening of the pressure relief valve. Additionally, it is believed that the gradual volatilization of the electrolyte occurs due to the deformation of the rubber cap, leading to eventual capacity loss and open failure. 【Overview】 ■Appearance Comparison - Conducted visual inspection of normal and degraded products. ■Internal Comparison using X-ray CT - Conducted internal observation of normal and degraded products using X-ray CT. *For more details, please refer to the PDF document or feel free to contact us.
Inquire About This Product
basic information
For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
catalog(15)
Download All Catalogs

Company information
Aites was established in 1993, originating from the quality assurance department of the IBM Japan Yasu office. Based on the technical expertise cultivated through cutting-edge defect analysis and reliability assurance of electronic components at the IBM Japan Yasu office, we have provided various products and services that support the development and manufacturing of semiconductors, displays, organic EL, solar cells, and electronic components to customers both domestically and internationally.