By installing supply ducts for ducted air conditioning units and external air handling units on the secondary side, ions are supplied from all indoor air supply outlets, achieving virus sterilization, deodorization, and energy-saving air conditioning.
By installing AQS in the air supply section of the ventilation system, the air quality and hygiene levels of the ventilated indoor environment will dramatically improve. Odors generated from outdoor air and indoor sources are detected and identified, and are reliably removed through oxygen ion reactions. Additionally, by measuring and detecting the generation capacity of oxygen ions, as well as indoor and outdoor air quality, air supply volume, and humidity with sensors, it becomes possible to quantify the invisible air and generate the appropriate ions indoors, thereby consistently creating an optimal indoor environment. Furthermore, by monitoring the data measured by air measurement sensors, it is possible to confirm that the indoor air, which changes daily, is being maintained hygienically. It is possible to disinfect airborne bacteria, with disinfection effectiveness data nearing 90%. Installation in the air supply duct allows for infection control in indoor spaces. It is possible to reduce the air conditioning airflow and hygienically increase the proportion of air that is reused (heat recovery) that is expelled outdoors. - Neutralization and removal of airborne bacteria (mold, bacteria, yeast) and odor substances (tobacco, ammonia, hydrogen sulfide). - Effectiveness against viruses, pollen, PM2.5, and VOCs, which can impact human health. - Prevention of hospital-acquired infections.
Inquire About This Product
basic information
Ionair Concentration Adjustment Device (ICE-A1000/2000 a/m) *The control of ion generation concentration corresponds to the variable air volume of the air conditioning unit. Furthermore, by checking the air conditions with various sensors installed in the ducts and supplying the appropriate amount of ions, the indoor air cleanliness will be dramatically improved. Ionair Ion Generation Module IMM Series (Small) IMK Series (Medium) IMG Series (Large) Ion Tube Length: 190 mm / 250 mm / 360 mm / 530 mm Applicable for: Supply Air / Extracted Air / Exhaust Treatment / Recirculated Air Installation Location: Inside Air Handling Unit (AHU) / Air Duct (Note) The number of ion tubes will be calculated by Ionair based on the air conditioning ventilation frequency and area volume of the target area. Please contact us for inquiries. There is no interference with the design. No daily maintenance or replenishment is required (annual maintenance once a year). Inquiries through Ipros have been stopped. Please contact us directly at: P 03 3288 3220 E info@ionair.jp
Price information
The price varies depending on the quantity.
Applications/Examples of results
Air purification / Ventilation volume suppression effect (energy saving and CO2 reduction) Inactivation effect of airborne viruses (proven products) (Implemented facilities) Hotels, stores, shopping malls, amusement facilities (casinos) Subway stations, schools, event facilities, offices, restaurants, airports Infection prevention measures in medical facilities such as nursing homes and hospitals Removal of odor substances (deodorization) - Deodorization of garbage storage rooms, cleaning facilities, and sewage treatment facilities - Air purification in laboratory animal facilities and food factories - Deodorization of smoking areas Implementation results (partial) Wynn Resorts Casino (Macau, China) Park Hyatt / Grand Hyatt Hotels (Shanghai, China) Shopping mall "dez" (Innsbruck, Austria) Zurich International Airport (Switzerland) Siemens TS (Berlin, Germany) St. Jakob-Park soccer stadium (Basel, Switzerland) Kanazawa Umimirai Library (Ishikawa Prefecture) Canton Hospital (Aarau, Switzerland)
Detailed information
-
This is an image of installation in a duct.
-
It is an image of being installed inside the air conditioning unit. It can be installed without damaging the ductwork.
-
This is an image of ion generation. By applying a constant high voltage to the generation tube, oxygen ions are produced from the air. Oxygen ions have properties similar to ozone, including odor removal and the ability to decompose chemical substances, but a characteristic of oxygen ions is that they have no impact on the human body.
-
This is an example of the AQS system configuration. By installing four types of sensors in the air conditioning ducts, air measurements are conducted. Based on that data, an appropriate ion concentration is generated. Additionally, the measurement data used during generation can be linked with the building management system.
Line up(3)
Model number | overview |
---|---|
IMM Series | Effective indoor space volume (300 - 800 m3) Ideal for air purification in small spaces and living rooms, as well as installation in individual rooms. |
IMK Series | This model is designed for medium-sized spaces. It accommodates effective room volumes of 600 - 3600 m3 due to the configuration of the ion generation tube. |
IMG Series | This model is designed for large facility spaces. It covers air purification for an entire floor or an entire building. Effective room volume of 1200 - 7200 m3 per unit. Multiple IMG series units can be installed. |
catalog(2)
Download All CatalogsNews about this product(1)
Company information
Founded in 1993 under the name "LK Luftqualität AG," we are currently operating under the name "ionair." We are a company that offers Swiss-made deodorization, air purification, and energy-saving systems, boasting over 10,000 installations in Japan. The ionair system generates oxygen ions using the corona discharge effect. It produces fresh and clean air without the use of chemicals, ultraviolet light, or ozone. Additionally, it is designed for use in occupied environments. - Deodorization Effect - By exposing polluted air to oxygen ions, the system oxidizes and decomposes odor-causing substances and VOCs, breaking them down and neutralizing them, transforming them into water and carbon dioxide. - Air Purification Effect - Indoor air is more than five times more polluted than outdoor air. Ionair decomposes and neutralizes harmful substances such as chemicals, pollen, and viruses using oxygen clusters that have no adverse effects on the human body. - Energy-Saving Effect - By equipping the ducts of first-class ventilation air conditioning systems, it is possible to reduce the airflow of the air conditioning unit. Furthermore, by increasing the amount of recirculated air and reusing exhaust air, significant reductions in electricity costs related to air conditioning and heating can be achieved.