Eliminate abnormal pressure fluctuations in the small space between the outer shell of the SF double-shell tank made of FRP and the inner shell made of steel at low cost! No need for repairs at each location every time an anomaly is detected!
Underground tanks at facilities handling hazardous materials such as SS have been equipped with SF double-walled tanks since around 1994, and as of March 31, 2011, a total of 41,572 SF double-walled tanks have been installed. In this situation, during leakage inspections of underground tanks, abnormal pressure fluctuations have been confirmed in the small space between the outer FRP shell and the inner steel shell of the SF double-walled tanks. Even if the cause is identified and the leakage point is repaired, there are cases where new abnormalities appear elsewhere, or abnormalities in different locations are confirmed several years after the first repair, making it impossible to guarantee that past repair work will be completed in one go. However, the fire department is also struggling with the reality that they cannot provide strong guidance due to economic issues. Our company's "Underground Storage Tank Leakage Detection Device with Inner FRP Double-Wall Structure" offers a low-cost solution to these problems. 【Benefits】 - There is no need to repair each location every time an abnormality is detected. - The number of facilities that cannot be repaired due to economic reasons decreases, reducing the risk of accidents. - Even facilities that cannot be inspected frequently can be safely monitored from a remote location. *For more details, please download the PDF or contact us.
Inquire About This Product
basic information
For more details, please download the PDF or contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please contact us or download the PDF document to view.
catalog(1)
Download All CatalogsCompany information
Currently, environmental destruction due to global warming is progressing on a global scale. Amidst this, in our country, leakage accidents have occurred at aging hazardous material storage facilities in various regions, and environmental destruction caused by soil contamination has become a serious social issue. Additionally, due to amendments to the Fire Service Act regarding underground storage tanks, leakage prevention measures have been made mandatory. The government is also taking proactive measures, such as partially subsidizing soil contamination environmental conservation projects at fueling facilities, but soil conservation measures must be addressed as a problem that requires cooperation between the public and private sectors. Our company is enhancing related products for leakage prevention measures, focusing on underground tanks and piping, so that owners of hazardous material storage facilities can operate their businesses with peace of mind. We hope to be of assistance to everyone with our many years of rich experience and reliable technology. ● FRP lining construction for underground tanks, etc. (Patent No. 3594183) ● Piping lining ● Construction of solvent tanks (Patent application 2014-185015, Utility model application 2015-003503) ● Steel tank inner surface FRP double-shell structure [with leakage detection device] (Patent application Japan 2012-256961, Utility model No. 3196696) (Patent Australia No. 2012-101365)