Due to the panel system, construction and adjustments in dimensions can be easily made, allowing for dismantling, relocation, and reassembly during layout changes, with no need for restoration to the original state when vacating the building.
- The adoption of "SUS double mesh" at the intake points for "light" and "air" has eliminated the need to install air conditioning and lighting fixtures indoors. - This is a prefabricated panel-type shield room that has a short on-site construction period and allows for easy relocation and modification. - By using SUS double mesh for the daylight windows and ceiling openings, we have eliminated the durability issues and clogging associated with previous mesh shield rooms, making lighting fixtures, ventilation equipment, and fire alarm systems unnecessary. - Unlike traditional sealed spaces, this design allows for visibility both inside and outside, creating a sense of openness. It is lightweight and easy to construct, and in office spaces within tenant buildings, there is no need for construction on the building side. Layout changes after installation can be easily managed without the need for dismantling, relocation, or reassembly, and there is no requirement for restoration to the original state upon departure. - The design is tailored to the intended use and specifications, and due to the panel system, construction and adjustments in dimensions can be easily carried out.
Inquire About This Product
basic information
【Features】 ● The windows and ceiling openings are made of SUS double mesh, eliminating the need for air conditioning, lighting, and ventilation. ● The panel is modular, making it easy to move, expand, and modify. ● Shielding function: SUS panel ● Shielding performance: over 70dB (10MHz to 1,000MHz) ● Standard size (external dimensions): W2,600 × H2,200 × L4,000 ● Floor (interior): galvanized steel plate + plywood + long vinyl sheet
Price range
Delivery Time
Applications/Examples of results
● Small anechoic chamber for wireless LAN ● Quality control and development of household electrical appliances (white goods, AV equipment, communication devices, etc.) ● Quality control and development of industrial equipment (machine tools, control equipment, office equipment, etc.) Noise countermeasures for industrial machinery such as discharge machining and high-frequency welders ● Quality control and development of industrial equipment (medical devices, gaming machines, measuring instruments, etc.) ● Quality control and development of automotive equipment (navigation systems, air conditioning, audio systems, etc.) ● Quality control and development of electronic components (control boards and mounted electronic components, etc.) ● Other quality control and development of electrical and electronic equipment required for EMC testing
Detailed information
-
Simple Shield Room - Door Open From the previously sealed space, both the interior and exterior can be seen, creating a sense of openness without feeling constricted. It is lightweight and excellent in terms of construction. In office spaces within tenant buildings, there is no need for construction on the building's side, and layout changes after installation can be easily dismantled, relocated, and reassembled, eliminating the need for restoration to the original condition upon departure.
-
Simple shield room, door closed. By eliminating the durability and clogging issues of previous mesh shield rooms and using SUS double mesh for the light windows and ceiling openings, we have made unnecessary the noise source lighting fixtures, ventilation equipment, and fire alarm systems.
-
Simple Shield Room - Interior The light windows and ceiling openings are made of SUS double mesh, eliminating the need for air conditioning, lighting, and ventilation. As it is a modular panel, it is easy to move, expand, and modify. 1) Ceiling light window (installation position is flexible) 2) Wall light window - wall panel 3) Filter panel Shielding function: SUS panel Shielding performance: over 70dB (10MHz to 1,000MHz) Standard size (external dimensions): W2,600 × H2,200 × L4,000 Floor (interior): Zinc-coated steel plate + plywood + long-length PVC sheet
-
Simple shield room with indoor daylight windows and ceiling openings made of SUS double mesh, requiring no air conditioning, lighting, or ventilation.
-
Simple Shield Room Filter Panel Appearance
-
Simple shield room Wall daylighting window ~ wall panel
-
Simple shield room Wall panel outer joint
-
Performance table
catalog(1)
Download All CatalogsCompany information
Our mission is to add our unique ideas and know-how to the new materials that are continuously emerging, in order to meet the needs of various industries, and to propose them as new products with added functionalities. Our functional composite materials demonstrate excellent and original capabilities across various fields, including home appliances, precision instruments, medical equipment, construction, and transportation, as well as in areas such as equipment parts, special rooms, and architectural panels, thereby contributing to society. Our pride lies in our development capabilities that continue to lead the industry, reflecting the times and exploring the next generation. We offer a wide range of products for electromagnetic wave countermeasures. Furthermore, we have established a system that allows us to consistently provide everything necessary for effective and efficient implementation, from on-site electromagnetic wave environment measurement and surveys to construction advice and shielding work. Technology is not born overnight. Our employees value a proactive attitude, especially when it comes to "technologies that no one else is doing," "technologies that are deemed impossible," and "unique technologies." Not everything in development is successful; in fact, failures are more common. However, it is also true that the byproduct technologies born from these challenges support our company today.