1~17 item / All 17 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us OnlineBefore making an inquiry
Download PDF1~17 item / All 17 items
This document explains nitrogen removal. Nitrogen compounds are frequently used as fertilizers and food additives, as well as in industrial applications. However, when released excessively into the environment, they can have harmful effects. Therefore, we will introduce the "Biological Nitrification Denitrification Method" as a way to remove nitrogen compounds! We provide detailed information on the three main methods and the treatment flow using diagrams. [Contents (excerpt)] ■ What is "Nitrogen"? What are the "problems" caused by "Nitrogen"? ■ What is the "Biological Nitrification Denitrification Method"? ■ The role of microorganisms ■ What is "Nitrification"? ■ What is "Denitrification"? ■ Overview of treatment facilities ■ The three main methods of the "Biological Nitrification Denitrification Method" *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document presents case studies on the water treatment methods for nitrogen components (ammonium) and zinc, which are present in high concentrations in plating wastewater. Since ammonium and zinc are found in high concentrations in plating wastewater, an effective method is to reduce ammonia using ammonia stripping, which volatilizes it as ammonia gas, followed by coagulation and sedimentation treatment for zinc. In cases where ammonia is at a significantly high concentration, it is anticipated that ammonia may remain even after ammonia stripping treatment. Therefore, a combined method is employed, which includes discontinuous point chlorine treatment using hypochlorous acid after the coagulation treatment, achieving treatment to a level suitable for river discharge. The PDF document provides detailed information on the treatment flow. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFactory wastewater and boiler blowdown water often have acidic or alkaline pH values, making it impossible to discharge them as they are. Adjusting such wastewater to a neutral range (around pH 7) is referred to as "pH neutralization treatment." In your factories, you are likely conducting pH neutralization treatment for wastewater such as waste acids and waste alkalis, as well as for coagulation reactions. Generally, two common methods of pH neutralization treatment are observed: ◯ Carbon dioxide method ◯ Chemical addition method This document introduces the various types of pH neutralization treatments and explains how pH neutralization is carried out. *For more details, please download the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationNormal hexane extract substances" are primarily indicators of oils, including animal and vegetable oils such as salad oil, as well as mineral oils like various oils. In particular, food manufacturing and processing plants, cosmetic manufacturing plants, and semiconductor manufacturing plants generate wastewater that contains a high concentration of "normal hexane extract substances." If discharged without treatment, it can cause pipe blockages, corrosion, and unpleasant odors, making proper treatment essential. This document provides a brief summary of commonly used methods for treating normal hexane extract substances. *This document clearly outlines the "principles" and "advantages/disadvantages" of each method. Please refer to the PDF download for details. [Contents] - What are "normal hexane extract substances"? - Why is treatment of "normal hexane extract substances" necessary? - Two methods for treating "normal hexane extract substances.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA "specific facility" refers to facilities installed in factories or business establishments that discharge wastewater or waste liquids, as defined by government ordinances or regulations. (1) Those containing substances harmful to human health (hazardous substances) (2) Those that may cause damage to the living environment (living environment items) Among the ordinances related to water quality regulations, there are also ordinances that differ by region. Here, we introduce the laws and ordinance regulations applicable to business establishments in Shiga Prefecture. 【Water Quality Regulation Laws and Ordinances in Shiga Prefecture】 - Water Pollution Prevention Act - Ordinance establishing discharge standards based on Article 3, Paragraph 3 of the Water Pollution Prevention Act (supplementary ordinance) - Shiga Prefecture Pollution Prevention Ordinance (Pollution Prevention Ordinance) - Shiga Prefecture Ordinance on the Prevention of Eutrophication of Lake Biwa (NP Ordinance) - Lake and Marsh Law - Sewerage Law Our company responds to inquiries regarding the Water Pollution Prevention Act, Shiga Prefecture Pollution Prevention Ordinance, NP Ordinance, etc. We can also support you from planning and drafting to execution on how to handle wastewater. For more details, please download the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the design, construction, and consulting for an electrochemical treatment wastewater treatment facility at a cosmetics factory. Since the factory mainly manufactures shampoo, body soap, and sunscreen (UV), the wastewater contains a high concentration of normal hexane extractable substances. By using electric ions generated to adsorb impurities, we can separate emulsified fats from the wastewater and form flocs (aggregates). By removing these from the wastewater, we can discharge the treated water into the sewer system. Previously, we used a coagulation-sedimentation method for treatment, but since switching to the electrolysis method, we have been able to reduce the amount of sludge generated by 70-80%. 【Case Overview】 ■ Facility: Cosmetics Factory Electrochemical Treatment Wastewater Treatment Facility ■ Biochemical Oxygen Demand (BOD): Raw water 710 → Treated water 370 ■ Normal Hexane Extractable Substances: Raw water 150 → Treated water 3 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company utilizes know-how based on extensive experience and achievements to handle the design, construction, maintenance, water quality analysis, and consulting for wastewater treatment facilities in various factories. Currently, we are offering a "document" that introduces various services related to water treatment and includes case studies of wastewater treatment specific to different factories, such as cosmetic factories, meat processing plants, and seafood manufacturing facilities. [Featured Case Studies] ■ Kimchi Manufacturing Plant (Fat Decomposition Treatment Facility) ■ Cosmetic Factory (Electrolytic Treatment Facility) ■ Construction Machinery Manufacturing Plant (Coagulation Sedimentation Treatment Facility) ■ Meat and Seafood Processing Plant (Contact Oxidation - Biological Treatment Facility) ■ Pig Farm Waste Treatment (Batch Reactor Treatment Facility) *For more detailed information, please refer to the "PDF Download." *This document summarizes the content of our operational site "Water Treatment Consultation.com."
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where we provided design, construction, and consulting for an electrolytic treatment wastewater treatment facility at a cosmetics factory. Since the factory mainly produces shampoo, body soap, and sunscreen (UV), the wastewater contains a high concentration of normal hexane extractable substances. By using electric ions generated to adsorb impurities, we separate emulsified fats from the wastewater and form flocks (aggregates). By removing these from the wastewater, we can discharge the treated water into the sewer system. Previously, we used a coagulation-sedimentation method for treatment, but since switching to the electrolytic method, we have been able to reduce sludge generation by 70-80%. 【Case Overview】 ■ Facility: Cosmetics Factory Electrolytic Treatment Wastewater Treatment Facility ■ Biochemical Oxygen Demand (BOD): Raw water 710 → Treated water 370 ■ Normal Hexane Extractable Substances: Raw water 150 → Treated water 3 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the design, construction, and consulting of a biological treatment wastewater treatment facility located in a meat and seafood manufacturing plant. The contact oxidation-biological treatment method adopted at this facility involves filling the biological treatment tank with fixed contact media, utilizing the purification effect of aerobic microorganisms that adhere to the surface of the media for treatment. To maximize installation costs and maintenance efficiency, the facility employs a semi-underground design. Additionally, a deodorization device using a scrubber system is installed to neutralize and discharge odors generated during the treatment process. 【Case Overview】 ■ Facility Type: Meat and Seafood Manufacturing Plant Biological Treatment Wastewater Treatment Facility ■ Biochemical Oxygen Demand (BOD): Influent 420 → Effluent 6.3 ■ Suspended Solids (SS): Influent 60 → Effluent 4.0 ■ Normal Hexane Extractable Substances: Influent 22 → Effluent less than 0.5 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where we provided design, construction, and consulting services for a batch reactor type wastewater treatment facility for pig farms' manure and urine treatment. The manure and urine discharged by pigs raised on the farm result in high-concentration wastewater, so we have adopted a natural purification method reactor system for undiluted treatment. This system artificially creates the process by which organic matter turns into soil (self-purification in swamps and lakes) within the reactor tower of the treatment tank and applies it to the treatment of organic wastewater. To save space, this treatment method employs a batch system that allows aeration, sedimentation, and discharge of treated water all within a single tank. 【Case Overview】 ■ Facility Type: Batch Reactor Type Wastewater Treatment Facility for Pig Farm Manure and Urine Treatment ■ Biochemical Oxygen Demand (BOD): Raw Water 7300 → Treated Water 16 ■ Nitrogen Content (T-N): Raw Water 3400 → Treated Water 18 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where we provided design, construction, and consulting services for a fat decomposition wastewater treatment facility at a kimchi manufacturing plant. In this facility, we adopted a fat decomposition system as a pretreatment for biological treatment, which is unsuitable for high concentrations of fats. This system breaks down fats into a form that is easier for biological treatment. For the biological treatment, we employed a contact aeration method that generates less excess sludge and is easier to maintain. In conventional treatment technologies, fats are difficult to decompose and can negatively affect microorganisms, making pretreatment of fats essential through methods such as grease traps and coagulation pressure flotation devices. By adopting the "fat decomposition system" as a solution to many issues, fats are decomposed, eliminating the need for large-scale treatment equipment. 【Case Overview】 ■ Facility: Kimchi manufacturing plant, fat decomposition wastewater treatment facility ■ Biochemical Oxygen Demand (BOD): Raw water 2000 → Treated water 230 ■ Normal hexane extractable substances content: Raw water 150 → Treated water 15 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case where we provided design, construction, and consulting services for a coagulation sedimentation wastewater treatment facility at a construction machinery manufacturing plant. The washing wastewater generated during processes such as painting in the manufacturing of construction machinery contains a large amount of heavy metals and phosphorus, which is why this facility employs a coagulation sedimentation treatment method. To efficiently treat the heavy metals and phosphorus contained in the wastewater, lime and coagulants are added to the reaction tank to effectively generate coagulation flocs. Additionally, by adjusting the pH, the generated coagulation flocs are allowed to grow larger, and then, through a sedimentation tank, the flocs are settled by gravity, achieving good solid-liquid separation. The clear supernatant water is discharged as treated water, while the settled sludge is removed from the system in the dewatering process. [Case Overview] ■ Facility Addressed: Coagulation Sedimentation Wastewater Treatment Facility at a Construction Machinery Manufacturing Plant *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWater treatment systems vary in content depending on the site. We consider various technologies and provide proposals that are more suitable for each specific site. 【Wastewater Treatment】 ■ Organic wastewater treatment systems for each factory ■ Inorganic wastewater treatment systems for each factory ■ Hospital wastewater treatment facilities ■ Livestock wastewater treatment facilities ■ Various treatment facilities such as manhole pumps ■ Disposer systems ■ High-concentration wastewater treatment systems ■ Pond and river purification systems ■ Septic tanks, etc. 【Maintenance and Inspection】 ■ Water quality inspection ■ Instrument inspection ■ Repair of equipment and blower replacement, etc. ■ Repair of equipment and other facilities 【Water Quality Analysis】 ■ Factory wastewater analysis ■ Industrial water analysis ■ Domestic water analysis ■ Groundwater analysis ■ Sewer analysis ■ Septic tank effluent analysis ■ River water, lake water, seawater analysis ■ Soil analysis, etc. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the "repair and maintenance" of the wastewater treatment facilities at Environmental Creation Co., Ltd. Failures in water treatment facilities can lead to environmental accidents immediately, as they are terminal facilities. Our company takes swift action to respond to such troubles, and naturally collaborates with relevant organizations to provide appropriate responses based on a wealth of information. [Features] ■ Swift action to address troubles ■ Collaboration with relevant organizations ■ Appropriate responses based on more information *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the "maintenance and management" of the wastewater treatment facilities at Environmental Creation Co., Ltd. Keeping the water treatment facilities in a consistently stable and appropriate condition is the most important yet also the most challenging task. Through daily and periodic management, we maintain constant communication with our customers, exchanging opinions to consider and propose better operational management. 【Features】 ■ We maintain constant communication with our customers during daily and periodic management. ■ We exchange opinions to consider and propose better operational management. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWater treatment systems vary in content depending on the site. We consider various technologies and propose systems that are more suitable for each specific site. For all types of water, including industrial water, river water, organic wastewater, and inorganic wastewater, we utilize all treatment methods such as physical treatment, chemical treatment, electrical treatment, and natural purification. We take into account initial costs, running costs, ease of operation, adaptability, scalability, and energy efficiency to propose suitable systems. 【Water Treatment】 ■ Sand filtration system ■ Iron and manganese removal system ■ Sand removal system ■ Softening system ■ Pure water system *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur environmental analysis department strives to provide feedback to our customers on the conditions at the site, as interpreted from measurement results such as water quality analysis, to assist in maintenance and management. We handle various items including factory wastewater analysis, industrial water analysis, and domestic water analysis. Please feel free to contact us. 【Various Water Quality Analyses】 ■ Factory Wastewater Analysis ■ Industrial Water Analysis ■ Domestic Water Analysis ■ Groundwater Analysis ■ Sewage Analysis ■ Wastewater Treatment Plant Analysis ■ River Water, Lake Water, Seawater Analysis ■ Soil Analysis *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration