46~66 item / All 66 items
Displayed results
Filter by category
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Contact this company
Contact Us Online46~66 item / All 66 items
Filter by category

In food processing plants, thorough hygiene management and a clean manufacturing environment are required to maintain product quality and ensure safety. If appropriate traps are not installed in the drain piping, there is a risk of air flowing in through the drainage system, allowing dust, odors, and contaminants to enter the air conditioning unit. Drain traps for air conditioning units ensure proper drainage while preventing backflow of air, contributing to the maintenance of a hygienic manufacturing environment. Our high static pressure drain traps maintain stable water seals even in high static pressure air conditioning units exceeding a total static pressure of +1450Pa by significantly increasing the water seal height, supporting air conditioning equipment in facilities that require high hygiene management, such as food processing plants. 【Usage Scenarios】 - Air conditioning equipment for food manufacturing lines - Air conditioning equipment for refrigerated and frozen warehouses - Air conditioning equipment in clean rooms 【Benefits of Implementation】 - Suppresses the growth of mold and unpleasant odors, maintaining a hygienic environment - Prevents the intrusion of outside air, reducing the decline in air conditioning effectiveness - Allows for flexible customization according to the installation environment
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
In hospitals, maintaining a clean and hygienic air conditioning environment is crucial for ensuring patient safety. If appropriate traps are not installed in the drain piping, there is a risk of air flowing in through the drainage system, allowing dust and contaminants to enter the air conditioning unit. Drain traps for air conditioning units prevent backflow of air while ensuring proper drainage, contributing to the maintenance of a hygienic air conditioning environment. Our high static pressure drain traps significantly increase the water seal height, maintaining a stable water seal even in high static pressure air conditioning units exceeding a total static pressure of +1450Pa, thus supporting air conditioning systems in facilities that require advanced hygiene management, such as hospitals. 【Usage Scenarios】 ■ High static pressure air conditioning units in operating rooms and sterile rooms ■ Spaces such as ICUs and infectious disease wards that require differential pressure management ■ Medical facilities utilizing high static pressure air conditioning units 【Benefits of Implementation】 ■ Maintenance of hygienic environments in operating rooms and sterile rooms ■ Reduction of contamination risks due to backflow of air ■ Stable operation of air conditioning systems
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The high static pressure drain trap is an FRP drain trap designed to be installed in high static pressure air conditioning units in hospitals, research institutes, and factories. The standard model (Type A Trap P) can handle a static pressure of up to +1450Pa, but by significantly increasing the water seal height, it can accommodate: Medium-sized FRP body: total static pressure 0 to +2000Pa Large-sized FRP body: total static pressure 0 to +3000Pa. *The photo shows the medium-sized FRP body. Additionally, it can flexibly accommodate changes in the positions of the inlet and outlet, allowing for customization to fit the installation environment. By filling the inside of the body up to the top of the outflow side components and forming a water seal, it prevents air from escaping. *It is necessary to regularly replenish water during periods when drainage does not occur. 【Features】 ■ Rust-proof and rot-proof FRP body ■ Significantly increased water seal height compared to conventional products ■ Height adjustment for inlet and outlet is possible
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The high static pressure drain trap is an FRP drain trap designed for high static pressure air conditioning units installed in hospitals, research institutes, and factories. The standard model (A-Trap P type) can handle a static pressure of up to +1450Pa, but by significantly increasing the water seal height, it can accommodate: Medium-sized FRP body: total static pressure 0 to +2000Pa Large-sized FRP body: total static pressure 0 to +3000Pa. *The photo shows the medium-sized FRP body. Additionally, it can flexibly accommodate changes in the positions of the inlet and outlet, allowing for customization to fit the installation environment. By filling water up to the top of the outflow side components inside the body, it prevents air from escaping by forming a water seal. *It is necessary to regularly replenish water during periods when no drainage occurs. 【Features】 ■ Rust-proof and rot-proof FRP body ■ Significantly increased water seal height compared to conventional products ■ Height adjustment of inlet and outlet is possible
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The high static pressure drain trap is an FRP drain trap designed for high static pressure air conditioning units installed in hospitals, research institutes, factories, and commercial facilities. The standard model (A-Trap Type P) can handle a static pressure of up to +1450Pa, but by significantly increasing the height of the water seal, it can accommodate the following pressures: Medium-sized FRP body: total static pressure 0 to +2000Pa Large-sized FRP body: total static pressure 0 to +3000Pa. *The photo shows the medium-sized FRP body. Additionally, it can flexibly accommodate changes in the positions of the inlet and outlet, allowing for customization to fit the installation environment. By filling the body with water up to the top of the outflow side components, a water seal is formed to prevent air from escaping. *It is necessary to regularly replenish water during periods when drainage does not occur. 【Features】 ■ FRP body that does not rust or rot ■ Significantly increased water seal height compared to conventional products ■ Height adjustments for inlet and outlet are possible
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The float ball type "C Trap Condesation Prevention Type" is a drain trap with doable wall structure that prevents condensation, with eliminating the need for insulation work. Its transparent condensation-prevention layer not only remove the need for-on-site insulation but also make it easy to chesk for internal dirt. 【Features】 ■ Prevents condensation with a double wall structure ■ No insulation work required ■ Features a transparent condensation prevention layer ■ Easy visual inspection of internal dirt *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
In the sterilization room of a hospital, hygiene management is extremely important, and the cleanliness of the air conditioning drain pipes is part of that. The occurrence of mold due to condensation and dirt inside the drain pipes can increase the risk of hospital-acquired infections. The insulated C-trap allows for visual confirmation of internal dirt, helping to appropriately determine cleaning times and maintain a hygienic environment. 【Usage Scenarios】 - Sterilization room - Operating room - Clean room 【Benefits of Implementation】 - Maintaining the cleanliness of drain pipes - Reducing the risk of hospital-acquired infections - Improving maintainability
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "Float Ball Type Air Conditioning Drain Trap Series" is a product with excellent air backflow prevention performance due to its rational float ball mechanism. It features ease of installation and ease of inspection and cleaning. We offer two types: the "A Trap" for medium to large air conditioning units and the "C Trap" for small air conditioning units. 【Features】 ■ Excellent air backflow prevention performance ■ Easy installation ■ Easy inspection and cleaning *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "C Trap" is a compact drain trap for small air conditioning units. Installed on each unit, it prevents air backflow and protects the indoor environment from contamination. Even if the water seal is lost, the special float ball reliably prevents the backflow of contaminated air. It also provides excellent odor and insent prevention performance, Inaddition it can be used for various applications, such as drainage for automatic air release valves and expansion water drainage for electric water heaters. 【Features】 ■ Special float ball prevents the backflow of contaminated air ■ Compact design, ideal for drain traps of small air conditioning units ■ Internal components can be easily removed for inspection and cleaning ■Reflective tape allows easy visiblity ever in concealed areas ■ Horizontal mounting type *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "B Trap" uses the "BN Clean System," which employs powerful oil-decomposing bacteria Super H and a special biofilter to resolve various issues associated with traditional grease traps, making maintenance and management of grease traps easier. There are various standard models available (including FRP and SUS tanks of various capacities, gutter inflow types, pipe inflow types, and fire-resistant specifications). It can also be introduced into existing grease traps through modifications. 【Features】 ■ Prevents odors caused by decay ■ Improves sanitary conditions ■ Reduces the workload for maintenance and management ■ Prevents scaling in the outlet pipe ■ Reduces the burden on public sewer systems and septic tanks ■ Significantly decreases the number of required cleaning operations *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "DK-Tank" is a one-piece FRP tank that can be used for expansion tanks and fire-fighting supply water tanks. Unlike conventional panel-type tanks, one-piece tanks do not have seams, eliminating concerns about water leakage from deteriorating joints. Furthermore, on-site assembly work is unnecessary, saving the effort required for panel tanks. FRP is characterized by being lightweight, rust-resistant, and having excellent heat resistance and durability. Additionally, the positions of piping outlets can be adjusted flexibly. Please feel free to consult us regarding compatibility with hot spring water, well water, chemicals, and other special liquids. If you need FRP tanks for renovation or new construction projects, please do not hesitate to contact us. 【Features】 ■ FRP tanks with excellent mechanical strength and outstanding durability ■ Weighs about one-fifth of steel, making transportation and installation easy ■ No rust formation, ensuring hygiene ■ Consultation available for tanks for hot spring water and well water ■ Long-standing track record of supplying expansion tanks and supply water tanks ■ 50 years of reliable experience in manufacturing FRP tanks! * For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "HC Trap" is a trap system designed for use with eco-cute and electric water heaters. Incorporate the HT DV DC50, a high temperature drainage collection fitting while the C Trap employs the F-CT40 / 50 a float ball type trap. This system is suitable not only for the drainage of condensing gas water heaters (such as Eco-Jozu), but also for the drainage of refrigerated and frozer displey cases. 【Features of the High-Temperature Drainage Collection Fitting】 ■ Splash Prevention Structure - The flow straightening plate suppresses water splashing of and ensures smooth drainage from the storage tank. ■ Maintenance and Height Adjustment Compatibility - The bottom of the unit can be connected to HT VP 50 (VP 50), allowing for easy height adjustment. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "BN Clean System" is a wastewater treatment facility for the removal of animal and vegetable oil-containing wastewater in specific facilities. It uses a powerful oil-decomposing bacteria called Super H and a special biofilter. This system achieves a clean environment, labor savings, and low costs. Additionally, it can be individually designed according to wastewater conditions and installation locations. 【Features】 ■ No need for disposal of excess sludge ■ Very low odor ■ Usable in underground pits with shallow water depth ■ Easily meets sewage discharge standards ■ Easy maintenance and low running costs *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
As a measure to prevent hospital-acquired infections transmitted through the air, HEPA filters and room pressure control are commonly used to remove and discharge airborne droplets and dust particles. This document presents presents finding that highlight the potential for cross-contamination of air between patient rooms through the drain pipes of air conditioning units - an issue that had not previously been actively addressed - and reports confirming the effectiveness of countermeasures. [Contents (excerpt)] ■ Introduction ■ Traps for preventing Airflow In and Out ■ Overview of Measurement Experiments ■ Experiment 1: Airflow In and Out Between Adjacent Patient Rooms ■ Experiment 2: Airflow In and Out Between Patient Rooms on Different Floors ■ Conclusion *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
In recent years, with the increase in the size of buildings, the production of hot water supply equipment's storage tanks has also increased. However, at the same time, there has been a rising trend in corrosion incidents due to water quality deterioration, which has become a problem. The 'DK-R Storage Tank,' utilizing the characteristics of FRP materials that have long-term heat resistance and excellent chemical and corrosion resistance, aims to solve these issues and is expected to have a significant effect on the corrosion and lifespan of the tanks. 【Features】 ■ Excellent corrosion resistance ■ All water contact parts are made of FRP ■ No need for anti-corrosion materials ■ Long service life ■ Excellent heat resistance and chemical resistance *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
"FRP lining construction" is a method that can repair aging water tanks and restore their functionality. It resolves water tank issues without the need for replacement. Since it is possible to partially repair existing tanks, the functionality of the water tank can be restored in a short period and at a low cost. Of course, tanks that have developed holes due to deterioration can also be repaired. It accommodates various materials such as FRP, steel plate, reinforced concrete, and stainless steel for the tank body. If you have any concerns regarding water tanks, please feel free to consult us. [Features] - Short construction period and low cost compared to tank replacement - Lining is possible for tanks made of various materials, including steel tanks - Environmentally friendly method with reduced waste - Delivery can be made in as little as one week from the start of construction - Water tank deterioration diagnosis is also available - Years of experience in the FRP business with a reliable track record *For more details, please refer to the related links or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
In hotels, proper maintenance and management of water supply and drainage systems are essential to provide guests with a comfortable and clean environment. In particular, facilities such as water tanks, including water storage tanks and elevated water tanks, as well as grease traps, are crucial infrastructure that supports facility operations. Corrosion and leaks due to aging can lead to hygiene issues and a decline in equipment functionality. The "FRP lining construction," which can restore waterproofing and durability without removing or updating existing equipment, is a renovation solution that contributes to the longevity of hotel facilities and the reduction of maintenance costs. 【Usage Scenarios】 - Internal repairs and lifespan extension measures for water storage tanks and elevated water tanks - Renovation of kitchen system grease traps - Waterproofing and anti-corrosion measures for RC tanks - Restoration of functionality for equipment that has experienced leaks or corrosion 【Benefits of Implementation】 - Increased longevity due to improved waterproofing and durability - Cost reduction compared to equipment replacement - Reduced impact on operations due to shorter construction periods - Improved maintenance of sanitary conditions - Enhanced preservation due to reduced risks of leaks and corrosion
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
In semiconductor factories, maintaining stable manufacturing processes and a high level of cleanliness is extremely important. In particular, facilities such as water tanks (including receiving tanks and elevated tanks) and grease traps are critical infrastructure that supports facility operations. Corrosion and leaks due to aging can lead to hygiene issues and a decline in equipment functionality. The "FRP lining construction," which can restore waterproofing and durability without removing or updating existing equipment, is a renovation solution that achieves extended lifespan and improved maintainability while minimizing equipment downtime. Furthermore, it contributes to reducing environmental impact through waste reduction. 【Usage Scenarios】 - Internal repairs and lifespan extension measures for receiving tanks and elevated tanks - Corrosion and waterproofing renovations for grease traps - Waterproofing and chemical resistance improvement measures for RC tanks - Restoration of functionality for infrastructure equipment affected by corrosion and leaks 【Benefits of Implementation】 - Minimization of downtime due to short construction periods - Cost reduction compared to equipment replacement - Waste reduction through the utilization of existing equipment - Extended lifespan due to improved waterproofing and durability - Assurance of stable operations through enhanced equipment maintainability - Contribution to reducing environmental impact
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Here, we introduce the differences between "A Trap" and "C Trap." The "A Trap" is a floor-mounted drain trap for air conditioning units with the trap function built in a box shape desigh rational structur incorporates two check valves, ensuring intended for medium to large sized air conditioning units such as air handling units. The "C Trap" desighed for small air conditioning units. Compact and easy to install ever narrow spaces such as attics, it is mounted on each unit to prevent air backflow and protect indoor air quality. Typical applications include small air conditioning units such as fan coil units (with an internal static pressure up to -1000Pa), indoor units of multi-split air conditioners and floor-mounted package air conditioners. In addition, it can also be used for varius applications such as drainage frow automatic air vent valves and expansion water from electric water heaters. *For more details, please refer to the external link or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "BN Clean System" is a wastewater purification system that utilizes the power of biology. This system employs special biofilters and fine bubble generation devices to maximize the characteristics of the "Powerful Oil-Decomposing Bacteria Super H," which our company has successfully cultivated and developed. In bio-treatment grease traps, it is used as B-Trap. Additionally, it has achieved numerous results as a kitchen waste treatment facility for wastewater containing animal and vegetable oils in specific facilities. 【System Components】 ■ Powerful Oil-Decomposing Bacteria Super H ■ Special Biofilter ■ Fine Bubble Generation Device *For more details, please refer to the external link or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
In the fiscal year 2003, our technology, the "Fixed Bed Contact Aeration Method with Attached Lipid-Decomposing Bacteria," was selected and objectively validated in the field of organic wastewater treatment technology for small-scale businesses. This technology involves attaching highly active lipid-decomposing bacteria (Super H bacteria) to a fixed bed composed of a special biofilter, which decomposes pollutants, including animal and vegetable oils contained in kitchen wastewater. By regularly adding and replenishing the highly active lipid-decomposing bacteria, we aim to maintain stable lipid decomposition activity. 【Overview of the Demonstration Test】 ■ Name: Fixed Bed Contact Aeration Method with Attached Lipid-Decomposing Bacteria ■ Start of Operation: April 2000 *For more details, please refer to the external link or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration