1~31 item / All 31 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~31 item / All 31 items
The "α-Beat plus" is a new type of soft starter that debuted in September 2023. It does not produce inrush current, which is typically seen with star-delta starting methods. It does not require a cooling fan, and there is no need for harmonic or noise countermeasures, making it suitable for inverter backup as well. It can be delivered in a short time, has a small MCB capacity, and requires only three wires, making it compact, lightweight, and economical. It is suitable for fixed-speed equipment. Since it provides soft start and soft stop, it can mitigate shocks and can be used in various machines such as pumps to prevent water hammer, fans, conveyors, crushers, mixers, and kneaders. 【Features】 ■ A starter that does not produce inrush current ■ Suitable for inverter backup ■ Effective against water hammer *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star/V Star" is a fire pump certified control panel that can reduce generator capacity. The "VC Star" is a starter that gradually increases the voltage applied to the motor from zero to full voltage over a range of seconds to tens of seconds by controlling the conduction phase of a thyristor inserted between the power supply and the motor. The "V Star" is a starter that can utilize the characteristics of the generator to draw out its capacity, with the generator capacity determined at 50% voltage during initial startup, while the motor's starting torque is determined at 70% voltage. 【Features】 ■ Achieves smaller generator capacity ■ Space-saving, low-cost, and environmentally friendly fire pump certified control panel ■ Capable of reducing generator capacity ■ Obtained fire protection certification ■ Installation replacement possible for just the control panel *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star/V Star" is a fire pump certified control panel that can reduce generator capacity. The "VC Star" is a starter that continuously increases the voltage applied to the motor from zero to full voltage over a range of several seconds to several tens of seconds by controlling the conduction phase of the thyristor inserted between the power supply and the motor. The "V Star" is a starter that can utilize the characteristics of the generator to draw out its capabilities, with the generator capacity determined at 50% voltage during initial startup, while the motor's starting torque is determined at 70% voltage. 【Features】 ■ Achieves smaller generator capacity ■ Space-saving, low-cost, and environmentally friendly fire pump certified control panel ■ Capable of reducing generator capacity ■ Obtained fire certification ■ Installation replacement of only the control panel is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star/V Star" is a fire pump certified control panel that can reduce generator capacity. The "VC Star" is a starter that continuously increases the voltage applied to the motor from zero to full voltage over a range of several seconds to several tens of seconds by controlling the conduction phase of a thyristor inserted between the power supply and the motor. The "V Star" is a starter that can utilize the characteristics of the generator to draw out its capacity, with the generator capacity determined at 50% voltage during initial startup, while the motor's starting torque is determined at 70% voltage. 【Features】 ■ Achieves smaller generator capacity ■ Space-saving, low-cost, environmentally friendly fire pump certified control panel ■ Capable of reducing generator capacity ■ Obtained fire protection certification ■ Installation replacement of the control panel only is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star/V Star" is a fire pump certified control panel that can reduce generator capacity. The "VC Star" is a starter that gradually increases the voltage applied to the motor from zero to full voltage over a range of several seconds to several tens of seconds by controlling the conduction phase of a thyristor inserted between the power supply and the motor. The "V Star" is a starter that can utilize the characteristics of the generator to draw out its capacity, with the generator capacity determined at 50% voltage during initial startup, while the motor's starting torque is determined at 70% voltage. 【Features】 ■ Achieves smaller generator capacity ■ Space-saving, low-cost, and environmentally friendly fire pump certified control panel ■ Capable of reducing generator capacity ■ Obtained fire protection certification ■ Installation replacement of the control panel only is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage. Mechanical damage is significantly reduced. The start and stop are gentle, resulting in no impact and quiet operation. 【Features】 ■ Soft start ■ Kick voltage start ■ Soft stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage, significantly reducing mechanical damage. The gentle starting and stopping process eliminates shocks and operates quietly. 【Features】 ■ Soft Start ■ Kick Voltage Start ■ Soft Stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage and significantly reduce mechanical wear. The gentle starting and stopping process eliminates shocks and operates quietly. 【Features】 ■ Soft start ■ Kick voltage start ■ Soft stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage and significantly reduce mechanical damage. The gentle start and stop result in no jolts and quiet operation. 【Features】 ■ Soft start ■ Kick voltage start ■ Soft stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage and significantly reduce mechanical wear. The gentle starting and stopping processes eliminate shocks and ensure quiet operation. 【Features】 ■ Soft start ■ Kick voltage start ■ Soft stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage. Mechanical damage is significantly reduced. The gentle starting and stopping result in no jolts and quiet operation. 【Features】 ■ Soft start ■ Kick voltage start ■ Soft stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. [Challenge] In this factory, raw materials are transported using a bucket conveyor. The issue was that the shock during startup was damaging the belts and chains, forcing us to replace parts once a year (approximately 500,000 yen per replacement). [Solution] We adopted the soft starter "Soft Starter α-Beat," which minimizes mechanical shock during startup to the utmost. Even after four years, no parts replacement has been necessary. We have significantly reduced maintenance costs. Since it is a soft start, it prevents gear damage and greatly reduces mechanical damage. The startup and stop are gentle, resulting in no jolts and quiet operation. [Features] - Soft start - Kick voltage start - Soft stop - Various settings available to match machine characteristics - Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. [Challenge] In this factory, we use six conveyor belts, some up to 90 meters long. Direct connection causes a lot of vibration and issues. [Solution] By using the soft starter α-Beat, we have successfully reduced vibration by gradually starting the system! Since it is a soft start, it prevents gear damage and significantly reduces mechanical wear. The start and stop are gentle, resulting in no jolts and quiet operation. [Features] - Soft start - Kick voltage start - Soft stop - Various settings available to match machine characteristics - Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe soft starter "α-Beat" slowly starts and stops the machine. It solves problems such as "water falling and breaking the pipes" and "producing loud noises" when turning the pump on and off! 【Features】 ■ Soft Start / Soft Stop It slowly starts and stops the machine, preventing load collapse on conveyor belts and water hammer phenomena. ■ Multiple Frequency On/Off OK It is shockless, allowing for safe restarts. ■ Energy Saving Frequent stops when unnecessary are the best way to save energy. The machine will not break even after restarting. ■ No Heat Generation Once the start is complete, it bypasses to commercial power. No cooling fan is needed inside the panel. ■ No Harmonics No measures like those for inverters are necessary, making it economical. ■ Guaranteed Start Regardless of whether the load is heavy or light, it will definitely start eventually. ■ Gentle on Power Supply There is no large inrush current. ■ Compact and Lightweight Easy to handle. ■ Complete Follow-Up System You can directly contact the manufacturer if you encounter any issues.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationHere is an example of calculating generator capacity. In a certain high-rise condominium, it became necessary to calculate the capacity of an emergency generator. When calculated using the conventional star-delta starting method, the capacity turned out to be approximately 450 kVA, which was found to be a significant burden both spatially and economically. Therefore, we were consulted by the company to see if the generator capacity could be reduced a bit more. We conducted calculations using a special Condor starter "V-Star" for some of the larger loads, and it was found that we could reduce the capacity to approximately 300 kVA, contributing to a reduction in initial costs. In the related links, we have also posted various inquiries received from customers, so please take a look. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAs you may have noticed, natural disasters are becoming increasingly severe year by year, such as heavy rains, floods, earthquakes, and eruptions. These events lead to the disruption of social infrastructure and a rising trend in damages. In preparation for this, the need for emergency power supply systems and generators, which allow activities to resume without waiting for the restoration of a wide-ranging power supply network, is becoming increasingly recognized. The establishment, expansion, and maintenance of these systems are considered important issues. There may also be considerations for regular use without relying on external sources. However, when the load equipment that needs to be secured is motor-driven, the starting current can significantly increase the size of the generator. While this is necessary, the economic aspect cannot be ignored when it comes to implementation. Therefore, we recommend the use of the motor starter "Special Condorfa V-Star," which reduces generator capacity. By using this product, you can miniaturize your generator and reduce initial costs. Being smaller means that construction costs, installation space, maintenance costs, and CO2 emissions can also be reduced, leading to a decrease in burden and progress in strengthening society's resilience. Our company is striving to assist in any way possible, and we look forward to hearing from you. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDenko Kogyo has adopted a unique magnetic flux elimination method to avoid switching surges that cause various troubles, thus solving this issue. There are innovations on how to transition smoothly to operation without generating surges. All of our starters, including V-Star, VT-Star, and C-Star, utilize a method where magnetic fluxes cancel each other out, creating a non-inductive circuit, eliminating reactance, and transitioning to full voltage operation. This not only prevents moisture ingress and deterioration of insulation but also allows the starter coil to absorb surges and protect the motor, along with various benefits such as miniaturization and space-saving of the 42MC for operation. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAre you experiencing any issues related to starting, such as "severe voltage drop," "large inrush current," "the belt breaking during startup," or "unable to start due to heavy load"? Our company offers various solutions, including the soft starter "α-Beat," which can be adjusted to match the characteristics of your machinery, and the special Condor starter "V-Star," which significantly reduces generator capacity, helping to resolve various concerns. In the related links, we provide a gentle explanation of the role of starters with images, so please take a look. 【Resolving starting-related issues with starters】 ■ Electrical troubles - Severe voltage drop, large inrush current Breakers mist trip, generator is too large ■ Mechanical troubles - Belt breaks during startup, unable to start due to heavy load Sudden movement causes load collapse, repeated startups lead to damage *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe starter "V-Star" that we handle can reduce CO2 emissions. It allows for smaller generators, making it inexpensive, and the installation costs are low, requiring less space. Additionally, it has the advantages of producing less exhaust gas and noise, contributing to solving environmental issues. Please feel free to contact us when you need assistance. 【V-Star Features】 ■ Small generator ■ Low installation costs and space-saving ■ Overall inexpensive system ■ Less exhaust gas and noise *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce the types and characteristics of starting methods. "Direct-on-line starting" is characterized by a large power capacity, simplicity, and low cost. On the other hand, "reduced voltage starting" includes methods such as star-delta starting, reactor starting, condenser fan starting, special condenser fan starting, and soft starters. When a motor starts, a large current flows, generating significant starting torque, which can cause various electrical and mechanical issues. To avoid this, Denko Industry offers various starting methods. 【Direct-on-line Starting Characteristics】 ■ Direct Starting - Simple - Inexpensive - Large power capacity - Significant mechanical shock *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTo avoid direct connection troubles, the star-delta method is generally used, but there are issues here as well. Has the breaker ever tripped? The breaker can trip during "the switch from star to delta" and "when the starting torque is originally insufficient." You can find detailed information on each pattern in the related links. 【Why does the breaker trip?】 ■ Reason 1: When switching from star to delta ■ Reason 2: When the starting torque is originally insufficient *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce the benefits of implementing a starter by comparing it with intermittent operation pumps. When operating with direct-on-line starting and repeatedly turning ON and OFF, the pump and piping can break, so continuous operation is reluctantly adopted. By using "α-Beat," there is no shock at startup, which prevents damage to the equipment and allows for frequent ON-OFF cycles, enabling you to stop without hesitation when not in use. 【α-Beat Features】 ■ No shock at startup, preventing equipment damage ■ Allows for frequent ON-OFF cycles ■ Can be stopped without hesitation when not in use *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star" is a compact wall-mounted continuous voltage control starter that is easy to install. It allows for downsizing to a small capacity similar to that of the "V Star" generator. It is about half the size of a generator, making it suitable for tight spaces. Please consider using it in various situations such as renewing existing equipment and accommodating top runner motors. We also offer calculations for generator capacity. 【Features】 ■ Perfect for equipment updates ■ Easy to install due to its small wall-mounted design ■ About half the size of a generator ■ Proven track record *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe soft starter "α-Beat plus" is a new type of soft starter that debuted in September 2023. While maintaining its purpose, role, and basic functions, it improves usability, and for small capacities of 7.5kW or less at 200V and 15kW or less at 400V, it includes an external bypass contactor for operation! It resolves mechanical troubles that occur during starting and stopping with the soft starter! 【Features】 ■ Pumps - Gentle starting and stopping, resulting in no shock and quiet operation ■ Crushers - Extended lifespan due to soft start ■ Cooling Towers - No damage due to soft start *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "V-Star" is a special Condorfa starter that operates a 1400kW pump using a fixed emergency generator of 1000kVA at the airport and two mobile power vehicles of 500kVA each, totaling 2000kVA. In the case of a typical Condorfa starter, a generator of about 3000kVA would be required, making it economically advantageous in terms of total cost. Please feel free to consult us when needed. 【Features】 ■ Significantly reduces starting current and greatly saves power capacity ■ Effective against voltage drops and flicker in commercial power supply during startup ■ Provides about half the starting torque of direct connection, ensuring safety ■ Smooth transition from startup to operation without disconnecting the main circuit ■ Unique magnetic flux elimination method from Denko, making it resistant to frequency and preventing coil deterioration for a long lifespan *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star" is a certified control panel for fire pumps, marked with the symbol VC, and is a small wall-mounted type, making it easy to install. It's about half the size of a generator. Perfect for equipment upgrades. A savior for fire pump rooms. 【Features】 ■ Perfect for equipment upgrades ■ Easy to install due to its small wall-mounted design ■ About half the size of a generator ■ Too narrow to fit? This one will fit ■ Symbol: VC *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VC Star/V Star" is a fire pump certified control panel that can reduce generator capacity. The "VC Star" is a starter that gradually increases the voltage applied to the motor from zero to full voltage over a range of several seconds to several tens of seconds by controlling the conduction phase of a thyristor inserted between the power supply and the motor. The "V Star" is a starter that can utilize the characteristics of the generator to maximize its capability, with the generator capacity determined at 50% voltage during initial startup, while the motor's starting torque is determined at 70% voltage. 【Features】 ■ Achieves smaller generator capacity ■ Space-saving, low-cost, and environmentally friendly fire pump certified control panel ■ Capable of reducing generator capacity ■ Obtained fire safety certification ■ Installation replacement possible for the control panel only *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Soft Start / Soft Stop The machine starts up slowly and stops slowly. It prevents load collapse on the conveyor belt and water hammer phenomena. ■Frequent On/Off OK It is shockless, so you can restart with peace of mind. ■Energy Saving Frequent stops when not needed are the best way to save energy. The machine will not break even if restarted. ■No Heat Generation Once the startup is complete, it bypasses to commercial power. Cooling fans inside the panel are unnecessary. ■No Harmonics No measures like those for inverters are needed. Economical. ■Guaranteed Start Regardless of whether the load is heavy or light, it will definitely start moving eventually. ■Gentle on Power Supply There is no large inrush current. ■Compact and Lightweight Easy to handle. ■Comprehensive Support System You can directly contact the manufacturer if you have any issues.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration○Features ■The special Condor V-Starter is a NETIS registered product. ■Low starting current: It suppresses the starting current of the motor, allowing for a smaller generator. This is advantageous in terms of installation costs, maintenance costs, space, exhaust gas, and noise. ■Sufficient starting torque: While excessive suppression of current can reduce torque, the V-Starter increases torque during operation, providing peace of mind. ■Smooth starting: There are no shocks during the transition from starting to operation. ■Long lifespan: There are no electronic components. It has a proven track record of over 20 years.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces a series of electric starters characterized by energy efficiency, long lifespan, compact size, and cost reduction. With a soft start that considers the machinery, they are durable and long-lasting. The torque is appropriate and reliable, making them suitable for repeated operations. Please use this information to assist in product selection. 【Contents (excerpt)】 ■ Comparison of each starting method ■ Special Condorfa starter (V-Star) ■ Thyristor starter (Soft Starter α-Beat) ■ Reactor starter ■ Condorfa starter ■ Variable torque reactor starter (VT-Star) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "α-Beat" is a soft starter designed with consideration for gears, belts, and machinery. Since it features a soft start, it can prevent gear damage, significantly reducing mechanical wear. The gradual start and stop result in no jolts and quiet operation. 【Features】 ■ Soft start ■ Kick voltage start ■ Soft stop ■ Various settings available to match machine characteristics ■ Proven improvements in various equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration