Spring Water Scale Countermeasures [Electromagnetic Water Treatment Device Vol. 6]

We will introduce a case of installation on a submerged pump that had stopped due to calcium scale.

We would like to introduce a technical case study of the electromagnetic water treatment device "Hydroflow." The water from the spring pit located 15 meters underground at the power plant is supplied through pipes A and B, but it is extremely hard water. The submersible pump for drainage stops due to calcium scaling in about three months, requiring the replacement of the pump each time, which incurs significant costs and time, causing difficulties. Therefore, we installed the Hydroflow model S100 on the water lift pipe. The effective range of this device is approximately 5,000 meters before and after the installation location. This device is a semiconductor product that requires no installation costs or maintenance, and it has been operating smoothly for two years since installation. [Case Overview] ■ Challenges - The pump stops due to calcium scaling in about three months because of hard water. - Replacing the pump each time incurs significant costs and time. ■ Results - It has been operating smoothly for two years since installation. *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment Plant
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Solution for hard water scale in the use of bore water in Australia.

A case study of successfully preventing scale adhesion using polar utilization. We will introduce the situation before and after treatment with photos!

Here is an example of solving hard water scale issues in the use of well water in Australia. We successfully prevented scale buildup on the fins and pipes of spray cooling water using polar treatment. We have included photos showing the significant scale presence before polar treatment and the absence of scale afterward. For more details, please check the PDF download below. [Measures and Effects] ■ Successfully prevented scale buildup on the fins and pipes of spray cooling water using polar treatment. *For more information, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study on Corrosion Prevention Effects of Chilled Water in Air Conditioning Systems [Magnetic Water Treatment Device Vol. 6]

Installed on the supply header outlet side! An example showing a dark brown color compared to the untreated side.

There are two comparison devices for the internal pipe inspection; one utilizes a polarizer, while the other does not. A comparative inspection was conducted under conditions where the polarizer was not used. One polarizer model "PI-50F (2”)” was installed on the discharge side of the supply header for cold and hot water, with partial circulation treatment performed using the polarizer. After treatment, it was evident that old scale and rust had dissolved and flowed out, forming a magnetite anti-corrosion coating inside the pipe, which appeared smoother and had a dark brown color compared to the untreated side. The untreated side showed signs of corrosion and scale adhesion. [Case Study] ■ Installation Date: December 1985 ■ Purpose: Anti-corrosion and anti-scaling for cold and hot water equipment ■ Installation Method: Installed the polarizer model "PI-50F (50A)" on the outlet side of the supply header ■ Treated Water Volume: Treated more than 5% of the total circulating water volume *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Cooling Water (Chiller Water) Molding Machine Mold Case Study [Magnetic Water Treatment Device Vol. 2]

Cooling water volume increased by 16%! Red rust has been completely removed and changed to black rust.

Tests were conducted in the cooling passages of plastic molds with the aim of removing blockages caused by rust and scale using a polarizer, thereby restoring cooling effectiveness. Additionally, we confirmed whether the removal of red rust from the cooling passages and its reduction to black rust (magnetite) would lead to the formation of an anti-corrosion coating. As a result, when the rust that had dissolved into the water tank was collected and a magnet was applied, the rust was attracted to the magnet, indicating that it had transformed into magnetite. [Test Details] ■ Purpose - To remove blockages caused by rust and scale in the cooling passages of plastic molds using a polarizer, thereby restoring cooling effectiveness (increasing cooling water flow rate). - To confirm whether the removal of red rust from the cooling passages and its reduction to black rust would lead to the formation of an anti-corrosion coating. ■ Location: SK Corporation Headquarters (Gifu Prefecture) ■ Duration: January 21, 1992 - May 30, 1992 (24-hour continuous bench test operation) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Countermeasures (Hot Water Supply of Large Hospitals) [Magnetic Water Treatment Device Vol. 11]

This is an introduction to a case where water quality improvement was achieved through the effects of a polar magnetic water treatment device!

This is a case study of measures taken against red water in a certain hospital in Okayama City (approximately 15 years after construction). A "PI-25F" Polar unit was installed on the pump discharge side, treating more than 50% of the circulating water in a partial bypass method, with water samples taken from the hospital faucet every morning at 10 AM. Sixty days after installation, improvements in water quality were observed in all aspects, including general bacteria, iron content, odor, taste, color, and turbidity, due to the effectiveness of the Polar magnetic water treatment device, particularly confirming its effectiveness in addressing red water issues in hot water supply. [Case Study] ■ Client: A certain hospital in Okayama City (approximately 15 years after construction) ■ Installation Date: Installed on March 7, 1987 ■ Water Quality Analysis Location: Okayama Medical Laboratory Center Co., Ltd. ■ Sampling Method: Water samples taken from the hospital faucet every morning at 10 AM ■ Polar Installation Method: A "PI-25F" Polar unit was installed on the pump discharge side, treating more than 50% of the circulating water in a partial bypass method. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

About the cause of red water (300 households) [Magnetic water treatment device Vol. 2]

We will introduce examples of conducting water main extraction in various housing complexes and investigating corrosion within the pipes!

Since the 1970s, as a measure against red water in buildings constructed after that period, the Ministry of Construction has guided the increased use of PVC-lined pipes over white gas pipes (galvanized steel pipes). Furthermore, from the 1980s to the present day (2002), many buildings, apartments, and general residences have experienced occurrences of red water every morning. As a result, in various housing complexes, investigations were conducted on the corrosion of the water supply pipes by removing them. The findings revealed that most of the corrosion inside the pipes was caused by the potential difference between dissimilar metals at the valves and pipe joints, as well as damage to the PVC lining seals. It was determined that the dissolved oxygen in the water reacts electrochemically with the metals through the water. [Causes] ■ Most of the corrosion inside the pipes is due to the potential difference between dissimilar metals at the valves and pipe joints, and damage to the PVC lining seals. ■ The dissolved oxygen in the water reacts electrochemically with the metals through the water. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Countermeasures (Hotel Hot Water Supply) [Magnetic Water Treatment Device Vol. 9]

Installed with a partial bypass method on return pipe 65A! Introduction of a case where red rust in the boiler turned into black rust and red water stopped.

There was a complaint that red water was coming out of the hot water faucet in the guest rooms within three years of the hotel's completion, and various measures were taken, but the issue was not resolved at all. As a result, a Polar magnetic water treatment device "Model PI-25F" (3-point set) was installed in a partial bypass configuration on the return pipe 65A, treating about 20% of the circulating water volume. As a result, it was confirmed that the red rust in the boiler had turned into black rust, and the red water had stopped. [Case Study] ■ Issues - Despite the piping being made of stainless steel and plastic, red water occurred. - The cause of the red water was corrosion due to an abnormal oxidation reaction of dissolved oxygen (DO) in the water inside the steel hot water heater. ■ Measures - A Polar magnetic water treatment device "Model PI-25F" (3-point set) was installed in a partial bypass configuration on the return pipe 65A. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion and scale prevention for chilled water in air conditioning systems [Magnetic Water Treatment Device Vol. 7]

The water quality in the pipe is slightly alkaline! The pH has increased, there is less iron, the water is clear, and the corrosion resistance is significant.

This introduces the corrosion prevention, scale prevention, and water quality purification effects of chilled and warm water systems. To confirm the effectiveness of the newly installed chilled and warm water pipes, an internal surface inspection was conducted. A very thin, dense, and uniform white (inorganic) corrosion-resistant film was formed, and there was no occurrence of rust. The water quality inside the pipes was slightly alkaline, and the iron content was within the drinking water standards. The clips in the sample water also did not rust, resulting in excellent outcomes. [Case Study] - Installation Location: A certain hospital in Fukuoka Prefecture - Installation Date: February 16, 1999 - Polar Model: PI-50F x 2 units - Installation Location: Chilled and warm water equipment for air conditioning (2 units) - Installation Method: Partial (5%) back method *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red water countermeasures (18 years after construction, 85 households) [Magnetic water treatment device Vol. 5]

A Polar model PI-50CF is installed with a complete set of dedicated pump for independent circulation in a 40m3 water receiving tank!

The S.S. Heights in Shimizu, Shizuoka City, has reached nearly 20 years since its construction, so we installed a polarizer for the purpose of countering red water (protecting the water supply pipes). One month after installation, there was a slight outflow of rust (rust leaching action) within the pipes, causing the iron content to rise from 0.04 to 0.16. Three months later, it decreased to 0.13, and after six months, it returned to 0.04, demonstrating an exceptionally long-lasting rust prevention effect. 【Case Study】 ■ Installation Date: October 16, 2002 ■ Installation Location: S.S. Heights in Shimizu, Shizuoka City (85 households) ■ Model: Polarizer Magnetic Water Treatment Device PI-50CF (Connection Diameter 50A) ■ Installation Method: Installed in an independent circulation system with a dedicated circulation pump in the water storage tank ■ Installation Details: 85 households, 18 years since construction, water storage tank (effective 40m3) ■ Purpose: Corrosion prevention to suppress aging of the water supply pipes *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion prevention effect of newly built air conditioning chilled and hot water【Magnetic Water Treatment Device Vol.5】

The iron content of the treated hot and cold water has decreased from 0.15 to below 0.05, which is a reduction of one third!

At the headers of the cooling and heating water system of Fukui Prefectural Hospital, a polar magnetic water treatment device was installed along with a dedicated circulation pump, and the circulating water was treated using a partial draw-off method. As a result, significant improvements in water quality were achieved for the hot water system, with pH and silica levels showing marked enhancement, and the Langelier index rising from -1.9 (highly corrosive) to +0.9 (non-corrosive). The cold water system also showed significant improvements in water quality, with the Langelier index changing from -1.9 (highly corrosive) to -0.2 (very slight corrosion). However, the iron content in both the treated hot and cold water decreased from 0.15 to below 0.05, a reduction of one-third, indicating that the risk of corrosion is negligible. [Case Study] ■ Installation Location: Headers of the cooling and heating water system of Fukui Prefectural Hospital ■ Polar Model - For cold water system: Model PI-50CF × 1 set (Trial operation on November 1, 2003) - For hot water system: Model PI-50CF × 1 set (Trial operation on November 1, 2003) (Size selection was carried out by our company) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Polar Technology Case Study] Confirmation of anti-corrosion effect on air conditioning chilled and hot water pipes after 17 years and 5 months.

The remaining lifespan of the cold and warm water pipes is estimated to be over 20 years! Thanks to Polar's rust prevention, there are no rust lumps on the inner surface of the pipes.

We would like to introduce a case where the anti-corrosion effect was confirmed on air conditioning chilled and hot water pipes 17 years and 5 months after polar treatment. Due to the anti-corrosion action of the polar treatment, there are no rust lumps on the inner surface of the pipes, which are covered by an extremely thin, dense, and uniform anti-corrosion film that has absorbed minerals. This film prevents the reaction (corrosion) between oxygen in the water and iron, thus providing corrosion protection. [Case Study] ■ Location: A certain major home improvement center ■ Installation Date: October 2002 (17 years and 5 months have passed since installation at the time of new construction) ■ Purpose: Anti-corrosion measures for newly installed air conditioning chilled and hot water equipment *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment Plant
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sterilization Effect Test Report

Each bacterium was tested three times, and the average value was calculated for the bacterial count! The test results are clearly presented in a table.

This document introduces the antibacterial effects of using polarizers. A mixed solution of Staphylococcus aureus, Escherichia coli, and Legionella adjusted to approximately 1.0×10^5 CFU/ml was flowed into the polarizer, and the viable bacterial counts before and after were confirmed using culture methods. Each bacterium was tested three times, and the average value was taken as the bacterial count. The test results are presented in a table for clarity, so please take a look. [Contents] ■ Test Request Form ■ Test Sample Name ■ Test Purpose ■ Test Method ■ Test Results *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Scale prevention and corrosion protection for cooling water systems [Magnetic Water Treatment Device Vol. 12]

Scale prevention and corrosion protection for cooling water systems! Installation of open cooling tower PI-150F (1 set) (1215 m3/h).

We would like to introduce a case of scale prevention and corrosion protection for cooling water systems at S Lightweight Metal Industry Co., Ltd. in Aichi Prefecture. On April 18, 1999, we installed a PI-150F (1 unit) open cooling tower (1215 m³/h). Photos of the installation are included in the PDF document. Please take a look. 【Case Details】 ■ User: S Lightweight Metal Industry Co., Ltd. (Aichi Prefecture) ■ Purpose: Scale prevention and corrosion protection for cooling water systems ■ Installation Date: April 18, 1999 ■ Model: PI-150F (1 unit) open cooling tower (1215 m³/h) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Countermeasures (27 years after construction, 271 households) [Magnetic Water Treatment Device Vol. 4]

Everyone is surprised by the speed of the results! Here’s an example where the red water stopped within about a week of installation.

The Nagoya City M Century Mansion has been in existence for 27 years, and red water started coming out of the taps. Therefore, the board of directors considered various methods for one year and decided to adopt the Polar system. Water was sampled and analyzed from the room next to the manager's office. The red water stopped within about a week of installation. Everyone was surprised by the quick results. 【Features】 ■ User Name: Nagoya City M Century Mansion (27 years old, 271 households) ■ Purpose: Red water countermeasures (2 tanks of 60t water storage + 1 tank of 30t elevated water storage) ■ Installation Date: January 25, 2001 ■ Polar Model: 2 units of PI-65 installed in an independent circulation system for each 60t water storage tank *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measures Against Red Water (2.5 Years After Construction) [Magnetic Water Treatment Device Vol. 8]

All analysis items are within drinking water quality standards! Cases demonstrating effects equivalent to those of chemical additives.

Tokyo Max Beauty College did not have red water at that time, but it was treated with chemicals as a future measure against red water. They discontinued that and installed a Polar system, which had been confirmed effective in other buildings, for the purpose of preventing red water. The water quality analysis report one month after installation showed that all analysis items were within drinking water quality standards. The iron content was also low, and the treatment by the Polar system demonstrated effects equivalent to the chemical treatment before the installation of this system. Future expectations include prevention of skin irritation. [Case Study] - Installation Location: Tokyo Max Gakuen Tokyo Max Beauty College (2.5 years after construction) - Installation Date: August 29, 2001 - Polar Model: PI-32CF (3-point set) complete set *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Prevention Measures for Red Water (13 Years After Construction) [Magnetic Water Treatment Device Vol. 7]

Confirmed that the chromaticity has greatly improved! A case of installing the Polar model PI-25CF in a water storage tank.

The owner of the Sendai TM Building has experience spending tens of millions of yen on lining methods for red water measures in other buildings. Since this building has also been in use for 13 years, a cost-effective and reliable technology polarizer was installed as a red water measure. Water quality analysis after installation confirmed a significant improvement in color. [Case Study] ■ Installation Location: Tokyo Max Co., Ltd. Sendai TM Building [13 years after construction] ■ Installation Date: September 22, 2001 (Saturday) ■ Polarizer Model: PI-25CF (3-point set) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red water countermeasures (13 years after construction, 30 households) [Magnetic water treatment device Vol. 6]

Adopting an independent circulation system! Installing PI-25CF (3-piece set) in a 13-year-old, 30-unit apartment building.

We would like to introduce a case of red water countermeasures implemented at East Side Palace T&T (a 30-unit condominium built 13 years ago) by Testa Corporation. We installed the PI-25CF (3-point set). We adopted an independent circulation method that extracts water from the suction side of the pump, processes it with a polarizer, and then feeds it into the water tank through a blow pipe. 【Case Details】 ■ Installation Location: East Side Palace T&T, Testa Corporation ■ Installation Date: August 26, 2002 ■ Installation Time: Approximately 5 hours; no water outage due to the presence of an elevated water tank ■ Polarizer Model: PI-25CF (3-point set) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measures against scale and corrosion in newly constructed cooling water systems [Magnetic Water Treatment Device Vol. 13]

Installed using a pump intake method! It processes 10% to 15% of the cooling circulating water volume.

We will introduce measures against scale in newly constructed cooling water systems. In 2001, JUS Citizen Hospital (Osaka City) was completed. At that time, our Polar system was introduced for air conditioning. For two absorption chiller/heaters of 300RT each, "PI-100F" was installed with a pump, processing 10% of the circulating water volume of 10m3/min as standard. Additionally, "PI-32CF" was installed with a pump for the cooling water of the cogeneration self-generating system (CT-100RT). Due to the high temperature of the water, 15% of the circulating water volume of 1035L/min is processed as standard. [Overview] ■ Installation Location: JUS Citizen Hospital (Osaka City) ■ Installation Date: June 16, 2001 ■ Installation Method: Pump intake method ■ Installation Details: Processing 10% to 15% of cooling circulating water volume ■ Installation Purpose: Prevention of scale, corrosion, and water quality purification in the cooling water system *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Prevention Measures [Magnetic Water Treatment Device Vol. 1]

Four large polar units installed using the independent circulation method! Introduced for corrosion protection of the water supply piping and the entire facility.

Introducing measures against red water. At MH Techno Garden, which consists of two 24-story buildings and four 6-story buildings, four units of "PI-125F" (2 units) and "PI-100F" (2 units) were installed using an independent circulation method for the purpose of corrosion prevention of the entire water supply piping and equipment. A diagram of the installation of the large polar units is included in the catalog. Please feel free to download and take a look. [Case Overview] ■ Installation Location: MH Techno Garden (Chiba Prefecture), completed in April 1990 (An office building composed of two 24-story buildings and four 6-story buildings) ■ Installation Date: February 6-8, 2003 ■ Model: PI-125F x 2 units, PI-100F x 2 units (total of 4 units installed) ■ Installation Method: Independent circulation method for each water tank ■ Equipment Details: Upper water tank 240m3 x 2 tanks, middle water tank 175m3 x 2 tanks ■ Purpose: Corrosion prevention of the entire water supply piping and equipment *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Akashui Countermeasures (86 households, 17 years after construction) [Magnetic Water Treatment Device Vol. 3]

A measure to prolong the lifespan by suppressing the deterioration of water supply pipes and preventing scale! Installed in a 17-year-old apartment building with 86 households.

Introducing measures against red water. A "Polar Magnetic Water Treatment Device PI-40CF (connection diameter 40A)" has been installed in the S.T Shin-Koiwa Mansion's underground water tank of 24m3 using an independent circulation method. This was introduced as a longevity measure to suppress the deterioration of the water supply pipes and prevent scale. The Polar Magnetic Water Treatment Device suppresses corrosion progression, gradually removes old rust, and forms a strong magnetite (black rust) anti-corrosion coating inside the pipes. 【Overview】 ■ Installation Date: December 6, 2002 (Friday) ■ Installation Location: S.T Shin-Koiwa Mansion ■ Model: Polar Magnetic Water Treatment Device PI-40CF (connection diameter 40A) ■ Installation Method: Installed in an independent circulation method with a dedicated circulation pump in the water tank ■ Equipment Details: 86 households, 17 years since construction, water tank (effective 24m3) ■ Purpose: Longevity measure to suppress the deterioration of the water supply pipes and prevent scale *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Safe and non-polluting "Polar Magnetic Water Treatment Device"

Norwegian magnetic water treatment device with an effective magnetic force of 6000 gauss.

The safe and eco-friendly "Polar Magnetic Water Treatment Device" is an ideal magnetic water treatment system for preventing the occurrence of scale, rust, and slime. The powerful magnetic field allows water to pass directly through, resulting in high effectiveness, and by treating just a small portion of the main pipe flow, it treats the entire water supply. For more details, please download the catalog.

  • Water Treatment
  • Water Treatment Plant
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Scale prevention for simple humidifiers [Electromagnetic Water Treatment Device Vol. 11]

Scale prevention for simple humidifiers! We will introduce a test conducted in a certain location in Setagaya, Tokyo.

This is a case study of a test conducted at a certain location in Setagaya, Tokyo (using tap water) with the electromagnetic water treatment device "Hydroflow." Using the Hydroflow HS38 model, we circulated and treated water from a 1-ton underground tank. We had been troubled by the persistent hard scale that adhered to the humidifier, but after treatment with this device, the scale (including silica) became soft enough to be easily removed with water washing. As a result, it was confirmed that the device is also effective in preventing the adhesion of silica-based scale. [Case Overview] - Test Period: December 1, 2008 - End of March 2009 (4 months) - Location: A certain place in Setagaya, Tokyo (using tap water) - Target Device: Humidifier (portable type) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of Effects Based on Cooling Tower Operating Time [Electromagnetic Water Treatment Device Vol. 8]

Comparison of 12-hour and 24-hour full operation! The algae and slime dirt in the cooling tower were treated with Hydroflow.

We would like to introduce a technical case study of the electromagnetic water treatment device "Hydroflow." There was contamination from algae and slime in the cooling tower, which was treated with Hydroflow. This is the condition of clean water during the 12-hour daytime operation. In comparison, other similar cooling towers operated continuously for 24 hours, so we compared the differences based on operating time. In conclusion, it was found that longer operating times resulted in cleaner and more effective outcomes. 【Case Overview】 ■Issues - Contamination from algae and slime in the cooling tower ■Results - A comparison between 12-hour and 24-hour full operation revealed that longer operating times were cleaner and more effective. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Chlorine reactivation provided by hydroflow treatment.

Measuring the total residual chlorine and free residual chlorine of each bottle! Here are the results.

Under the presence of Chairman Nakajima of the NPO Corporation Bathing Facility Hygiene Management Promotion Council, we conducted a test. Here are the details of the case. (1) to (3) The total residual chlorine and free residual chlorine of each bottle were measured. As a result, after A·K treatment, both total residual chlorine and free residual chlorine increased. [Test Method] ■ Water from the tap + a small amount of added chlorine (1) ■ Water from the tap contaminated with saliva (rutin) (2) ■ Water from the tap with monochloramine (flip-flap) added (3) *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Example of cost savings calculation when adopting a pool.

Introduction of a cost-saving calculation example when adopting Hydroflow for a pool.

At the outdoor pool of the Hong Kong University of Science and Technology, we were using an ozone generator for sterilization, but due to high electricity costs, we discontinued its use and installed three Hydroflow P160 (for 6"). As a result, we were able to maintain water quality safety, and we report this. The installation was made in March 2000 on a 150A pipe just before entering the sand filters (three units). The pool's water volume was 2,400m². 【Evaluation of Benefits】 ■ Discontinued the ozone generator, reduced the backwashing frequency of the filters to 1/3 and the cleaning time to 1/5, saving on drainage volume. ■ Reduced the usage of electrolyzed disinfectants to 1/3. ■ Overall costs saved approximately 1.4 million yen annually. ■ The water has become softer compared to before. ⇒ It has become gentler on swimmers' skin, eyes, hair, and swimsuits. For more details, please refer to the catalog or feel free to contact us.

  • Water Treatment Plant
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Effect of preventing algae and scale in cooling water【Electromagnetic Water Treatment Device Vol.2】

Introduction of case studies on the effects of hydroflow installation for preventing algae and scale in cooling water systems.

We will introduce a case study on the effectiveness of the "Hydroflow Electromagnetic Water Treatment Device" in preventing algae and scale in cooling water systems. The user installed it at a certain automobile manufacturer (Eastern Japan) to prevent algae in a 300RT cooling tower and to address scale and slime issues in the oil cooler and compressor. 【Installation and Effect Confirmation】 ■ Installed Model: Hydroflow Model: P200 installed on the 200A cooling water circulation line piping ■ Usage Period: Used for 3.5 months from October 2010 to March 2011 ⇒ No high-temperature shutdowns of the oil cooler and compressor (discontinued use of water treatment chemicals) For more details, please refer to the catalog or feel free to contact us.

  • Water Treatment Plant
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Countermeasures for Red Water in Tap Water [Electromagnetic Water Treatment Device Vol. 4]

Introducing a case study of Hydroflow installation in an apartment with old water pipes that produce dirty rusty water!

We would like to introduce a technical case study of the installation of the electromagnetic water treatment device "Hydroflow" in a certain apartment building in Tokyo. This apartment building has reached its 30th anniversary since completion, and the water supply pipes are old, causing dirty rusty water to come out of the faucet for about 10 to 30 seconds every morning, which was a problem. Therefore, we installed the Hydroflow P60 on the discharge pipe of the pressurization pump (50A). About two months later, the rusty red tap water every morning turned into clear, clean tap water, and the red water completely stopped without the need for chemicals or pipe rehabilitation. [Case Summary] ■ Issues - The water supply pipes are old, and dirty rusty water is coming out. ■ Results - The rusty red tap water every morning became clear, clean tap water. - The red water completely stopped without the need for chemicals or pipe rehabilitation. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Prevention of Algae Growth in Cooling Towers [Electromagnetic Water Treatment Device Vol. 7]

No occurrence of water algae, and the water is clear and beautiful! Issues such as scale and slime in the heat exchanger are also resolved.

We would like to introduce a technical case study of the electromagnetic water treatment device "Hydroflow." Green algae had developed at the bottom of the cooling tower, causing significant contamination, and there was a decrease in thermal efficiency due to scale and slime in the heat exchange section. Therefore, we installed the Hydroflow on the discharge side of the pump on the main pipe, and one month later, the water algae that passed through the Hydroflow turned brown, died, and accumulated. After that, we cleaned it once, but there was no further occurrence of water algae, and the water became clear and clean. 【Case Overview】 ■ Issues - Green algae had developed at the bottom of the cooling tower, causing contamination. - There was a decrease in thermal efficiency in the heat exchange section due to scale and slime. ■ Results - No occurrence of water algae, and the water became clear and clean. - Issues within the heat exchange, such as scale and slime, were also resolved. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Magnetic Water Treatment Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration