Water treatment equipment Product List and Ranking from 134 Manufacturers, Suppliers and Companies | IPROS

Last Updated: Aggregation Period:Feb 04, 2026~Mar 03, 2026
This ranking is based on the number of page views on our site.

Water treatment equipment Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Feb 04, 2026~Mar 03, 2026
This ranking is based on the number of page views on our site.

  1. ビー・テップ Gunma//Trading company/Wholesale
  2. サンエー工業 Tokyo//Facility Design Office
  3. 流機エンジニアリング 本社 Tokyo//Building Management
  4. 4 ヴァンテック Tokyo//Building materials, supplies and fixtures manufacturers
  5. 4 富士計器 本社 Hokkaido//Electricity, Gas and Water Industry

Water treatment equipment Product ranking

Last Updated: Aggregation Period:Feb 04, 2026~Mar 03, 2026
This ranking is based on the number of page views on our site.

  1. Vantech Pipe Comprehensive Catalog ヴァンテック
  2. Multi-pole magnetic field far-infrared water treatment device "Thunder System" 富士計器 本社
  3. Water treatment equipment (disinfection, iron removal, manganese removal) "Aqua Series" 川本製作所
  4. Well Water Filtration Device TC-12J 十字屋 (十字屋グループ)
  5. 4 High-precision adsorption water treatment device effective against PFAS: ECO Clean LFP 流機エンジニアリング 本社

Water treatment equipment Product List

61~90 item / All 433 items

Displayed results

Physical water treatment method with a magnetic field of 6000 Gauss or higher.

Introducing materials that cover an overview and structure of polarizers, their principles and effects, as well as main installation examples!

This document introduces the physical water treatment method using a polar magnetic water treatment device by Japan Selpo, which operates with a magnetic field of over 6000 gauss. It includes sections such as "Overview and Structure of Polar," "Main Installation Examples for Cooling Water Systems, Hot and Cold Water Systems, and Water Storage Tank Systems," and "Main Applications." Please take a moment to read it. 【Contents (partial)】 ■ Introduction ■ Recent Developments ■ Overview and Structure of Polar ■ Principles and Effects *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Effect of Open Cooling Towers on Algae Suppression [Magnetic Water Treatment Device Vol. 14]

A comparative test was conducted at a certain public facility in Tokyo! We will introduce a case where water clarity improved through polar treatment.

Two identical cooling towers are arranged in parallel using the same source water, and both cooling towers were cleaned in the same manner before entering the test. One of the cooling towers was equipped with the Polar magnetic water treatment device "PI-40F." The other continued to operate as usual with automatic blowdown using an algae growth inhibitor. The side using the inhibitor showed a significant presence of algae throughout, with a lot of foaming in the water, while the side using the Polar device showed no algae growth at all, and the water clarity improved compared to before. [Test Details] - Two identical cooling towers are arranged in parallel, using the same source water. - Both cooling towers were cleaned in the same manner before the test. - One of the cooling towers was equipped with the Polar magnetic water treatment device "PI-40F." - The chemical treatment side continued operation with automatic blowdown using an algae growth inhibitor. *For more details, please refer to the PDF document or feel free to contact us.*

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Examples of Softening and Dissolution of Cooling Water System Scale [Magnetic Water Treatment Device Vol. 3]

Comparison before and after use (2.5 months)! The softening and dissolution of scale was confirmed.

Water treated with magnetic processing using a polarizer causes softening and dissolution of scale. A polarizer model "PI-15(15A)" was installed in the test equipment to investigate the softening and dissolution outflow of scale in the test pipe. Comparing before the use of the polarizer and 2.5 months after its use, it was found that softening and dissolution of the scale occurred. It is considered that it may take a considerable amount of time to remove scale solely with the polarizer, so while the primary purpose is to prevent scale adhesion, it is believed that it does not have the rapid effectiveness of chemical cleaning for removing adhered scale, but it can prevent scale buildup inside the pipes. [Test Overview] ■ Provider: Environmental Frontier Co., Ltd. (Shizuoka City) ■ Test Period: June 1, 1984, to August 15, 1984 (approximately 2.5 months) ■ Purpose: Does water treated with magnetic processing using a polarizer cause softening and dissolution of scale? ■ Method: A polarizer model "PI-15(15A)" was installed in the test equipment to investigate the softening and dissolution outflow of scale in the test pipe. *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Countermeasures (Hotel Hot Water) [Magnetic Water Treatment Device Vol. 12]

We will introduce a case where the red water completely stopped, the water became transparent, and the troubles were resolved!

The effectiveness of Polar as a countermeasure against hot water red water was confirmed. In large buildings and hotels, after more than 10 years, the dissolved oxygen, chlorine ions, and pH in the water cause corrosion to progress on the inner surface of the pipelines, resulting in red water due to rust in the hot water and bath, which becomes a significant operational issue. In response to such troubles, Polar significantly suppresses the progression of corrosion without the need for chemical injection, resolving the red water issue. The facts regarding this matter were evaluated by a lining contractor in the residential newspaper "Amenity." [Case Study] ■ Purpose: Confirmation of the effectiveness of Polar as a countermeasure against hot water red water. ■ Installation: One unit of Polar model "PI-40F" was installed in a bypass manner on the main pipe to treat 50% of the hot water circulation volume magnetically (installed on June 5, 1987). *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case study on the removal of red rust from cooling water (chiller water) [Magnetic Water Treatment Device Vol. 1]

Conducting a test to confirm the effectiveness of rust removal! After the test, we will introduce cases where the rust was beautifully removed.

We would like to introduce the test conducted by our company to confirm the effectiveness of Polar in removing red rust. The water tank used was made from a drum that had been utilized during fire training, and it was quite rusty both inside and out. The purpose of the test was to observe how the rust on the inside and bottom, which came into contact with Polar water, would change. During the test, the rust inside the tank (drum) caused the water to become red and murky, making the bottom invisible. However, after the test, the rust on the inner walls and bottom that had come into contact with Polar water was completely removed. It should be noted that the upper part of the inner wall, about 10 cm high, which did not come into contact with Polar water, remained unchanged from before the test. [Test Overview] ■ Duration: February 23, 1989 - March 16, 1989 ■ Location: Underground boiler room of a certain automobile dealer headquarters in Nagano City ■ Purpose - To remove the red rust (Fe203) generated inside the sample pipe by Polar and to see if it can be reduced to black rust (Fe304). *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study on Scale Prevention in Closed Cooling Towers [Magnetic Water Treatment Device Vol. 6]

We will introduce a case where it was confirmed that there was no scale adhesion and successfully saved on water costs!

On October 24, 2000, a polar type "PI-25CF" was installed on the spray pipe of the cooling tower using a partial bypass method, and automatic blow management was conducted without chemicals at the conventional electrical conductivity of 60 ms/m. On November 22, 2000, one month after using the polar system, a check was conducted for scale deposition at the heat exchange section of the cooling tower, and no scale was found, confirming the effectiveness of the polar system. At 3.5 months of using the polar system, an extreme experiment was conducted by further concentrating the electrical conductivity to 120 ms/m to save on water supply, and it was confirmed that there was no scale deposition, successfully achieving savings on water costs. [Issues and Measures] - The supply water (well water) had a pH of 6.7, electrical conductivity of 30 ms/m, silica of 56 mg/L, M-alkali of 76 mg/L, and calcium of 31 mg/L, making water quality management very challenging. - The model "PI-25CF" was installed, which includes a magnet strainer, the polar main unit, and a flow meter. *For more details, please refer to the PDF document or feel free to contact us.*

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Red Water Measures (Water Supply and Hot Water Supply for Large Buildings) [Magnetic Water Treatment Device Vol. 10]

We installed a polar magnetic water treatment device! We will introduce a case where the red water completely improved and stopped after 6 months.

After 25 years since construction, the water supply and hot water became discolored due to the white gas pipes, causing discomfort. To address the red water issue and protect asset value, we installed the "Polar Magnetic Water Treatment Device." Subsequently, improvements of over 90% were confirmed by the 30th to 40th day, and after six months, the red water issue was completely resolved. The antibacterial activated carbon filter of "PDF-1" removed chlorine odors and trihalomethanes, which are carcinogenic substances, allowing us to enjoy delicious tea and water as magnetically activated water in a powerful magnetic field of 6000 gauss, which received great acclaim. [Case Study: Water Supply] ■ August 25, 2000 - Installed Polar model "PI-40CF" in a 30m3 water tank. ■ 45 days after Polar treatment - Red water stopped with iron content at 0.16mg/L. ■ Six months after Polar treatment - Both water supply and hot water taps were opened, passing without red water. *For more details, please refer to the PDF materials or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion prevention effect of chilled and hot water in hospital air conditioning systems [Magnetic Water Treatment Device Vol. 4]

A case where an electric control valve that had failed six times and was replaced before installation showed no failures after installation.

On March 3, 2003, a polarizer was installed (on February 1, 2000), and since three years have already passed, maintenance (management) was performed. After the installation of the polarizer, the red rust water turned into clear water about a week after treatment, and for the following three years, the water has remained clear and beautiful, indicating a very significant anti-corrosion effect. Additionally, before installation, about six electric control valves were malfunctioning and had to be replaced, but after installation, there have been no failures, leading to a very substantial economic benefit. [Case Study] - Installation Location: Certain Medical Center in Tokyo - Installation Date: February 1, 2000 - Model: PI-25CF x 1 unit - Target Equipment: Air conditioning chilled and hot water system - Installation Method: Partial (5%) back method *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Scale Countermeasures for Absorption Chillers and Hot Water Generators [Magnetic Water Treatment Device Vol. 5]

Due to the slime suppression effect, there is no slime at all! The scale adhesion prevention and corrosion resistance effects have been significantly demonstrated.

We conducted a performance verification for approximately 1 year and 3 months using only the Polar magnetic water treatment device on Sanyo's "400USRT" chilled and hot water generator. The upper water tank of the box-type cooling tower is covered with a lid to block sunlight, which is effective in preventing the growth of water algae. Thanks to Polar's slime suppression effect, there was no slime at all, and the prevention of scale adhesion and corrosion effects were significantly pronounced, receiving positive evaluations from both users and manufacturers. Additionally, the LTD (temperature difference) as an evaluation of heat exchange rate was also normal and satisfactory. 【Case Study】 ■ Application: Scale, corrosion, and slime countermeasures for the 400USRT absorption chilled and hot water generator ■ Installation Location: Ote Electronics Optical Manufacturer (Company N), Kumagaya City, Saitama Prefecture ■ Installation Date: End of July 2003 (installed by a major subcontractor) ■ Polar Model: PI-65F (Set of Polar main unit, magnetic strainer, and flow meter) ■ Installation Method: Installed using a pump draw method for 10% of the cooling circulating water volume *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Scale prevention measures for turbo refrigeration units used in air conditioning [Magnetic water treatment device Vol. 4]

A demonstration experiment aimed at comparing the effects of polar magnetic water treatment devices and chemical treatment.

Amidst the numerous manufacturers selling magnetic water treatment devices, there was a strong demand from major general contractors to confirm the effectiveness of these devices compared to the traditionally used chemical treatments. With the cooperation of subcontractors, comparative tests were conducted. For the university hospital, an anti-Legionella slime control agent was applied weekly at a rate of 500cc using a hand-spraying method, without utilizing any conventional chemical injection systems, particularly during the hot summer months. As a result, the effectiveness of the Polar magnetic water treatment device, which has a powerful magnetic force of over 6000 Gauss, was confirmed and evaluated. [Case Study] ■ Purpose and Application - Prevention of scale adhesion, corrosion, and slime suppression for a 150RT air conditioning turbo refrigeration unit ■ Installation Location: A certain university hospital in Saitama Prefecture ■ Start Date of Trial Operation: April 1, 1998 (installed by a major subcontractor) ■ Polar Model: PI-65F (set including Polar main unit, magnetic strainer, and flow meter) ■ Installation Method: Installed using a partial bypass method with over 15% of the circulating water flow rate of 1950L/min *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case study of the new air conditioning chilled and hot water pipes after 5 years [Magnetic Water Treatment Device Vol. 3]

Confirmed the formation of an extremely thin, dense, and uniform white (inorganic) corrosion-resistant film.

We would like to introduce the results of the effectiveness confirmation of the newly installed chilled and hot water pipes after five years. Nearly five years have passed since the installation of the polar system, and an internal surface inspection of the new chilled and hot water pipes was conducted to confirm their effectiveness. It was confirmed that an extremely thin, dense, and uniform inorganic protective coating had formed. Due to the protection provided by this coating, there was no occurrence of rust on the inner surface, confirming the excellent corrosion resistance of the polar system. [Case Study] ■ Installation Purpose: Corrosion prevention, scale prevention, and water quality purification for newly installed chilled and hot water ■ Installation Location: Chilled and hot water piping for air conditioning at Kyudenko Corporation, Fukuoka Branch Office ■ Installation Date: February 1999 ■ Model: PI-40F (3-point set) x 2 sets ■ Installation Location: Chilled and hot water equipment for air conditioning (2 locations: 2 units) ■ Installation Method: Installed with a partial return method for more than 5% of the circulating water volume *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Examples of Corrosion Prevention Effects of Cold and Warm Water [Magnetic Water Treatment Device Vol. 2]

Comparing water sampling before and after treatment, the anti-corrosion effect is obvious at a glance!

This introduces the actual corrosion prevention effects of cold and warm water systems. Before treatment, two water samples (500cc each) were taken, photographs were taken, and water quality analysis was conducted. After 1 to 3 months post-treatment, the water becomes clear, so sampling is conducted in the same manner as before, allowing for a clear comparison of the corrosion prevention effects (iron units are in mg/L). The PDF document includes comparative photographs. Please take a look. 【Comparison Case Lineup (Excerpt)】 ■ A certain university in Akita ■ A supermarket in Oga City, Akita ■ A certain general company’s Fukushima factory ■ A certain highway in Akita *For more details, please refer to the PDF document or feel free to contact us.

  • Housing structure technology/long-term superior housing technology
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Polar magnetic water treatment device "Rust prevention, scale countermeasures, slime suppression"

Prevent rust and achieve long-lasting piping. Here are examples of effectiveness in air conditioning chilled and hot water piping.

The "Polar Magnetic Water Treatment Device" is a product that can be installed in piping to prevent rust, scale buildup, and slime formation. It has a delivery record of over 6,000 units in Japan. It can be installed compactly and is used in various locations, including cooling towers, chillers, and various heat exchangers. The treatment does not use chemicals, and maintenance is easy. Partial treatment of circulating water is possible at 5-20%. [Effect Example in Air Conditioning Cold and Hot Water Piping] Location: A major home improvement center Condition: Installed during construction, 17 years and 5 months have passed Effect: A thin, dense, and uniform rust prevention film incorporating minerals suppresses the reaction between oxygen and iron in the water, achieving a piping system without rust lumps compared to untreated piping. *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment Plant
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Indoor Environment Purifier "Indoor Sterile"

The definitive solution for repelling 'hygiene' viruses! Introducing a purifying agent that excels in effectiveness and safety.

"Indoor Sterilization" is an indoor environment purification agent that can disinfect, inhibit bacteria, and deodorize. Chlorine dioxide gas oxidizes and destroys the cell membranes of viruses, airborne bacteria, and surface bacteria to achieve disinfection. We offer two sizes: 120g and 500g. 【Features】 ■ Disinfection ■ Antibacterial ■ Deodorization ■ Excellent effectiveness and safety *For more details, please refer to the PDF document or feel free to contact us.

  • Safety and consumables
  • others
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Disaster Water Purification Device "DASCO Type Emergency Water Purification Device"

9,400 units delivered! Equipped with automatic suction sterilization devices and fully self-priming pumps!

The DASCO-style "Emergency Water Purification Device" is a disaster water purification system that creates drinking water from nearby water sources during emergencies. With numerous delivery records in Japan and a wide range of variations from 0.5m³/h to 12m³/h, it is designed specifically for earthquakes and disasters, with the concept of providing a water purification device that is easy for first-time users to operate and can continuously supply safe water. **Features** - Uses filtration and adsorption elements - No operation required for switching between automatic and manual modes - Employs self-priming pumps and automatic suction sterilization devices - No tools required for normal use - All-in-one type - Portable enough for two people to carry the entire set - Utilizes a 4-cycle engine - No operation required for switching between automatic and manual modes - Comprehensive sales and maintenance network - Hollow fiber membrane filter and carbon dioxide neutralization device (optional) *For more details, please refer to the PDF document or feel free to contact us.*

  • Water Treatment
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Stream Water Dedicated Compact Purification Device 'Debactor SAC'

Disinfect and sterilize general bacteria and E. coli to provide safe water! Stabilization and lightweight of filtered water quality!

The "Debactor SAC" is a compact water purification device that removes color and turbidity during rainfall, disinfecting general bacteria and E. coli with uniform residual chlorine to supply safe water. It uses ceramic sand fine particles as the filtration material. Its features include a low specific gravity, high backwash efficiency, and a large surface area with excellent particle capture capability. This all-in-one type is lightweight enough to be transported by hand, and all internal piping and wiring are completed, allowing for completion on-site through "foundation work," "installation," "connection piping work," "electrical work," and "shed assembly work." 【Features】 ■ The main body is fully automatic and made of SUS304 stainless steel. ■ The processing capacity is 1m3/hour during rainy weather and 2m3/hour during sunny weather, providing safe water at maximum capacity. ■ It employs a pressure-assisted suction filtration method. ■ It is a standardized device that fits over 80% of water sources, reducing costs. ■ It minimizes the degradation of the filtration material, ensuring long-term maintenance-free operation. *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment
  • Water Treatment Plant
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Useful Case] Installation of a Small Water Purification Filter System in a Drinking Water Supply Facility

In addition to turbidity, it also addresses the removal of color! Case study of a small filtration system for spring water.

We would like to introduce a case where we delivered the small water purification device "Debactor SAC" to an administrative agency. We received an inquiry stating, "We have installed a water purification device for our drinking water supply facility, but it is aging, and we are considering an update. Is there a good water purification device available?" In response, we proposed our product, and we received the order and carried out the installation. It features a compact design and is a unit type that can be simply transported and placed, with a coagulant addition function. 【Case Overview】 ■ Installed Equipment: Small Water Purification Device "Debactor SAC" ■ Inquiry Details: The water purification device for the drinking water supply facility is aging; is there a good water purification device available? ■ Product Features - Compact design; unit type that can be transported and placed easily - Includes a coagulant addition function, allowing for the removal of not only turbidity but also color. *For more details, please refer to the PDF document or feel free to contact us.

  • Water Treatment
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Installation of the pulse-type water treatment device "Vulcan" to the cooling tower.

It enables chemical-free alternatives to conventional drug injections and water softeners, facilitating cost reduction and efforts towards ISO 14001 compliance.

The Burkan pulse system alters the natural crystallization process of calcium, transforming it from a jagged structure to a simple mono-crystal form, allowing it to remain suspended in water and preventing accumulation on surfaces. By using Burkan, you can maintain the maximum capacity of cooling towers and reduce water usage. It also reduces overall operating costs. Chemical agents are hardly needed (only a small amount of algaecide). It decreases bacteria and biofilm, extending the lifespan of cooling tower equipment. Cost-effectiveness can be achieved in a short period. For more details, please download the catalog or contact us.

  • others
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Installation of the pulse-type water treatment device "Vulcan" to the artificial snow machine.

We will maximize the capabilities of artificial snow machines as measures for better snow production.

The quality and quantity of snow produced by artificial snow machines are largely influenced by water quality. Bulkan's Electronics Pulse Technology transforms the disorderly clutter within well-aligned mono-crystals into a unique crystal-scale organization. The small droplets of water in the artificial snow machine become extremely fine. As a result of achieving a good crystal structure in the snow produced by the artificial snow machine, the slopes created by this machine can be used for a longer ski season. By using Bulkan, scale buildup on the spray nozzles is prevented and removed. Additionally, it allows for maximum snow-making capacity with reduced water loss. The snow produced after being treated with Bulkan is drier and forms finer snow crystals. ● For more details, please download the catalog or contact us.

  • others
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Soil Washing Method

From investigation to purification, we can respond consistently! We comprehensively assess various conditions and select suitable treatment methods such as soil washing, chemical/thermal decomposition, and bioremediation!

DOWA's ecosystem soil purification business conducts a comprehensive process from investigation to purification treatment and monitoring. It also broadly addresses not only heavy metals but also VOCs (volatile organic chlorinated compounds), oil contamination, buried waste, and complex pollution. 【Features】 ■ A reliable and reassuring support system that can consistently handle everything from investigation to purification ■ Investigations conducted with purification design in mind ■ Advanced simulation analysis by geological specialists ■ Support for risk management ■ Extensive capabilities for both nationwide and overseas investigations *For more details, please refer to the PDF materials or feel free to contact us.

  • Clean Room
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Compressor Drain Water Treatment Device "Drain ECO"

The post-treatment normal hexane value is below 5 ppm (mg/ℓ).

The oil-containing drain water discharged from the air compressor is treated to meet the wastewater discharge standards of the "Water Pollution Prevention Act" (with a normal hexane extractable substance content of 5 ppm or less) before being released. This is a groundbreaking device that combines oil-water separation functionality with adsorption treatment. 【Features】 ○ The combination of oil-water separation functionality and adsorption treatment achieves longer element lifespan and lower costs. ○ Significant cost reduction is possible by reducing drain treatment expenses. ○ Realization of factory wastewater reduction. For more details, please contact us or download the catalog.

  • Water Treatment
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Radioactive Contaminated Soil Washing Equipment Flow

Rapid and comprehensive purification of soil contaminated with radioactivity and heavy metals.

It is a system for comprehensively purifying soil contaminated with radioactivity and heavy metals.

  • Sewerage facilities
  • Other civil engineering works
  • Aggregate Production Machine
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Small Pump and Water Treatment Equipment Comprehensive Catalog 【Ogihara Manufacturing】

Comprehensive catalog of small pumps and water treatment equipment. Catering to a wide variety of needs.

Ogiwara Seisakusho's "Compact Pump and Water Treatment Equipment Comprehensive Catalog" addresses a wide variety of needs. We offer a lineup that can accommodate various applications and conditions, including "compact pumps" for designing and manufacturing water-related equipment, and "water treatment equipment" that proposes optimal water creation. Our "tool business" provides high-quality and short delivery time products through a consistent production system from mold making to molding. For more details, please contact us or refer to the catalog.

  • Air compressors, blowers and pumps
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Information] Amus RC40 and Amus Eco Plant System Method

Overview of the trial survey construction, results of the trial survey, and a collection of photographs from the trial survey construction are published!

This document introduces the "Ams RC40 and Ams Eco Plant System Method," which is a system method for on-site remediation (modification and restoration) technology using mobile plants in response to contaminated soil, as well as construction recycling resource utilization. It includes an overview of the "Trial Investigation Work," such as method comparisons and the procedures for the trial investigation work, as well as summaries of the "Modification and Restoration Technology of the Ams Eco Plant System" and a photo collection of the trial investigation work. Please take a look. [Contents] ■ Chapter 1: Overview of the Trial Investigation Work ■ Chapter 2: Summary of the Modification and Restoration Technology of the Ams Eco Plant System ■ Chapter 3: Results of the Trial Investigation ■ Chapter 4: Evaluation Items of the "Utilization Effect Survey Table" ■ (Material) NETIS Trial Investigation Work Photo Collection *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Soil improvement material
  • Other civil engineering works
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Dioxin-contaminated water treatment device Acryia DXN

Large processing volume and long-duration filtration

This is a completely new dioxin-contaminated water treatment device using a high-speed multi-layer fiber filtration method. It incorporates the advantages of multi-layer filtration systems in sand filtration, and the filtration tank is multi-layered with special acrylic fibers of varying diameters. As a result, it achieves a large processing capacity and long-duration filtration that cannot be obtained with conventional single-fiber diameters. The fiber filter media can be replaced, cleaned, and reused every few days.

  • Incinerators and chimneys
  • Other civil engineering works
  • Dismantling and moving
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Renovation Product Catalog

Introducing a wide range of products related to water treatment and organic matter treatment!

This catalog summarizes the renovation products handled by Kansai Chemical, which manufactures and sells water treatment-related products and organic matter treatment systems. It features a wide range of products, including the "temporary water treatment system," which is suitable for on-site construction periods where inflow of wastewater cannot be stopped, as well as "pressurized flotation devices" and "header pipes." [Contents] ■ Construction ■ Systems ■ Membrane units ■ Dehydrators ■ Filter housings *For more details, please refer to the PDF document or feel free to contact us.

  • Piping materials (plastic pipes)
  • Water Treatment
  • Turbid water and muddy water treatment machines
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ballast Water Treatment System PureBallast 2.0

Effectively treating microorganisms in ballast water with a compact design.

A simple and very easy-to-operate ballast water treatment system that meets the standards of IMO and PSC (Port State Control). PureBallast, with its space-saving design, chemical-free operation, and ease of use, provides the best solution for both installation and operation.

  • Turbid water and muddy water treatment machines
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Industrial high-performance oil cleaning agent - oil remover cleaner

Non-toxic, harmless, gentle on hands, and environmentally friendly oil dispersant.

Industrial high-performance oil cleaning agent, oil remover cleaner is a non-flammable industrial high-performance oil cleaning agent that takes the environment into consideration. It is non-toxic, harmless, and gentle on the hands, making it suitable for many applications beyond industrial use. The product is available in bottles of 1 gallon (3.78 liters) and 1 liter. Typically, the concentrate is diluted with water from several times to a hundred times depending on the application. For more details, please contact us or refer to the catalog.

  • Bathroom, shower, washbasin and toilet equipment
  • Safety and consumables
  • Concrete Machinery
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water Treatment Device Mold Water HS-15/HS-20

Red water and scale prevention! A water treatment device that can suppress red water using the power of magnetism.

"Mold Water" is a water treatment device that can suppress red water using magnetic power. The red rust that adheres to the inside of the pipes gradually transforms into black rust, forming a protective film that safeguards the pipes. Mold Water removes debris (foreign substances) that stick to the pipes and suppresses further adhesion. By purifying not only drinking water but also bath water that touches the skin, it allows for a safe and comfortable living environment. By using Mold Water, you can purify the pipes and suppress red water. The electric field generated by Mold Water causes water (H2O) to decompose, producing reactive oxygen (O). This reactive oxygen has a sterilizing effect. For more details, please contact us or refer to the catalog.

  • Sanitary fixtures
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water Treatment Device Mold Water MCS-15/MCS-20

In the branching parts of the header method for general residential buildings and in relatively short circulation circuits for factory cooling water.

"Mold Water" is a water treatment device that can suppress red water using magnetic force. The red rust that adheres to the inside of the pipes gradually transforms into black rust, forming a protective film that safeguards the pipes. By applying Mold Water, you can purify the pipes and suppress red water. "Mold Water MCS-15/MCS-20" is ideal for the branching parts of header methods in general residential settings (new installations) and for relatively short circulation circuits in factory cooling water systems. Since the magnets are smaller and fewer in number compared to the TE type, this product has a narrower effective range. Basically, it is recommended for use in areas where the distance between the "product and the target device/use point" is short. Additionally, when used in residential settings with a one-pass system, it is advisable to use it in new installations (equipment without dirt accumulation). For more details, please contact us or refer to the catalog.

  • Sanitary fixtures
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Search Keywords Related to Water treatment equipment