Generator×京都理化学器械 - List of Manufacturers, Suppliers, Companies and Products

Generator Product List

1~6 item / All 6 items

Displayed results

PSA Nitrogen Gas Generation System TAC-HP Series

Oil-free scroll compressor with built-in touch panel operation, nitrogen PSA. It is a nitrogen gas generation device that is gentle on both running costs and the Earth.

- Performance improvement with a compressor of the same output as before By reviewing the process that generates nitrogen gas, we have achieved performance improvement with a compressor of the same output as before. Particularly, there is a significant performance enhancement at high purity levels. A high-precision oxygen concentration meter is built-in, and the 99.999% specification has become the standard model. - New TAC energy-saving system combining three energy-saving technologies In addition to the adsorption/desorption cycle and compressor start-stop control, the number of built-in compressors and the PSA units are controlled as a unit according to the flow rate. Devices with multiple built-in PSA units (4.4 kW to 11 kW) can achieve more precise energy-saving operation. - Low noise, low vibration, and space-saving design The PSA units have been miniaturized to the extreme, and devices ranging from 4.4 kW to 7.5 kW have been further reduced in size. With a built-in scroll compressor, they operate with low noise and low vibration, making them suitable for installation on-site, even in densely populated residential areas and during nighttime operation. - Long maintenance cycle All unit switching valves use air-operated valves, and the maintenance cycle for the PSA units is two years. During long-life maintenance, rapid response is possible at service centers nationwide, along with the compressor parts.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PSA Nitrogen Gas Generation System TAC-mini Series

Achieves significant miniaturization and cost performance while maintaining the features of the higher-end TAC series equipped with energy-saving driving.

The TAC series, equipped with a long-life oil-free baby compressor, achieves significant miniaturization and cost performance while maintaining its original features. Of course, it is easy to operate with a touch panel. - Built-in inverter energy-saving operation It uses a three-phase motor and has a built-in inverter, allowing it to operate with the same performance at both 50/60Hz. It can also be used with single-phase 200V, making it possible to install in general offices even without a three-phase power supply. It also features energy-saving control through suction time control, managing the start and stop of multiple built-in compressors to avoid unnecessary operation. - High performance and space-saving While maintaining the same performance as devices with the same output, it achieves a volume ratio of 72.5% in dimensions. The measured noise level of the device is approximately 60dB(A). With casters, it can be placed anywhere without restrictions.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PSA-type nitrogen gas generator THP series

Achieves significant miniaturization and cost performance while maintaining the features of the higher-end TAC series equipped with energy-saving driving.

Microcontroller-controlled oil-free babycon built-in nitrogen gas generator Achieves low cost with simple functionality while maintaining the same performance as higher-end models. Necessary information can be displayed on the LCD panel. - Built-in oil-free babycon Equipped with an oil-free babycon using a domestic manufacturer's three-phase motor, enhancing reliability and durability. - Built-in inverter, no specific installation location required The oil-free babycon is controlled by an inverter, allowing for the same performance at both 50/60Hz. Single-phase 200V is also selectable, making it possible to install in general offices without three-phase power. - Long maintenance cycle for cost-effectiveness The unit switching valve employs an air-operated valve, and the maintenance cycle for the PSA unit is 20,000 hours, ensuring long life. The compressor has a durability of 10,000 hours in continuous operation and can be easily replaced by users.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PSA-type nitrogen gas generator Micro-mini series

Desktop ultra-compact PSA for university and research institute analysis devices and research/experimental applications.

Oil-free compressor built-in ultra-compact nitrogen gas generator - Built-in air pump with long lifespan and low noise By using the built-in compressor at 50% of its rated pressure, it achieves over 10,000 hours of durability, low power consumption, low noise, and low vibration. - Built-in solenoid valve miniaturization The solenoid valve has been miniaturized to the extreme at the manifold, improving maintainability. - Equipped with various sensors and LCD display, capable of repair response even in sudden troubles Equipped with oxygen concentration, flow, and current sensors, it constantly displays the operating status and shows error messages through a fail-safe function in case of abnormalities, ensuring safe shutdown. Maintenance and sudden troubles can be addressed by utilizing the advantages of its ultra-compact design for return and repair response.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PSA Nitrogen Gas Generator TN Series

20% increase in output with high purity (99.99%) equipment! Industry No. 1 performance.

Oil-free mini compressor with built-in oxygen concentration sensor - Microcontroller control • LCD display Nitrogen gas purity and operating time can be checked on the LCD display. If there is a purity anomaly or a problem with the compressor, the cause will be displayed on the LCD. * The compressor will stop in case of a malfunction. * If a purity anomaly alarm output is required, please request it at the time of order. - Low noise and high lifespan design Equipped with a proven low-noise, high-lifespan oil-free compressor (1 to 4 units), it features a structure with high soundproofing effects, allowing for use in quiet indoor environments. It is compact and lightweight, with a built-in water drain vaporization device, making it suitable for various installation locations.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PSA-type nitrogen gas generator SLM series

Revamped with future-oriented technology, significantly enhancing all performance, achieving extreme miniaturization and slimness, and realizing substantial noise reduction.

Oil-free mini compressor built-in nitrogen gas generation device - Easy maintenance without selecting installation location (internal structure is registered design) The fixing screws for the compressor during transport have been eliminated, and electrical wiring and piping connections can be made from the back without opening the casing. Regular inspections and maintenance can be performed simply by opening the front door. - Long maintenance cycle Equipped with multiple reliable oil-free compressors from domestic manufacturers. Improved ventilation efficiency within the device suppresses temperature rise, significantly extending lifespan. During maintenance, users can easily replace components. - High performance and space-saving While maintaining the same performance as devices with the same output, the dimensions have been reduced by 34% in volume ratio, and the device noise has been kept below 10 dB(A) based on actual measurements. *Comparison made with TNH4-19M5-2 and SLM-22L devices. Additionally, by changing the exhaust from the conventional rear exhaust to a concentrated upper exhaust, the ventilation space at the back has been eliminated, allowing for space-saving installation. *The direction of the exhaust can still be changed to the rear as before.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration