Investigation of Support Layer Penetration for Small Steel Frame Buildings | High-Precision Lambdasounding
Ground investigation
This is a ram sounding survey that accurately obtains deep support layer data essential for structural calculations, even in narrow sites where large heavy machinery cannot enter.
In the construction of steel frame buildings on small plots in urban areas, accurate understanding of the bearing layer is essential for high-load foundation design, but the limitations on the use of large boring machines pose challenges. Our service utilizes a small crawler-type automatic ram sounding testing machine to achieve high-precision deep investigations even in densely populated urban areas. The fully automatic striking device drops a 63.5 kg hammer from a height of 500 mm, automatically recording the Nd value for every 200 mm penetration, and continuously visualizing the bearing layers equivalent to an N value of 50 and the geological composition up to a maximum depth of 30 m. By correcting for surrounding friction through torque measurement, we provide high-precision data that can be directly compared to standard penetration test N values, ensuring the necessary ground evidence for structural calculations. Continuous measurements at multiple locations capture the inclination of bearing layers and changes in layer thickness, enabling optimal pile length design on a per-unit basis, thereby guaranteeing safe and economical foundation quality and the long-term safety of the building.
Inquire About This Product
basic information
This test is a sounding survey that employs an automatic continuous penetration method (such as YBM's CRS12). A hammer with a mass of 63.5 ± 0.5 kg is automatically dropped from a height of 500 ± 10 mm to penetrate a cone with an outer diameter of 45 mm and a tip angle of 90 degrees. The number of impacts Nd is recorded for every 200 mm of penetration, and when the number of impacts exceeds 5 (Nd > 5), the automatic measurement of the rod rotation torque Mv (N·cm) is conducted to perform a calculation correction (Nd = Nd - 0.00041Mv). The dimensions of the self-propelled crawler machine are a total width of 830 to 1000 mm and a total height of 2350 to 2570 mm, capable of reaching a maximum measurement depth of 30 m.
Price information
Please contact us.
Delivery Time
Applications/Examples of results
It is suitable for new ground surveys of steel frame buildings, low to mid-rise apartments, and commercial stores on narrow sites where large boring machines and scaffolding cannot be set up. It is mainly used in pile foundation design methods such as steel pipe pile method, ETP-G method, and tiger pile method to confirm the depth of the bearing layer (N value of 50 or more) and to understand the inclination. Additionally, it is widely used in structural design practices for obtaining evidence of ground evaluation in building confirmation applications and structural reviews, determining the allowable bearing capacity of deep layers in deformed ground after demolition, and optimizing costs to prevent excessive pile length design.
catalog(3)
Download All Catalogs
Company information
-






![Dry Wave Retractable Indoor Clothes Drying Rack [Good Design Award Winner]](https://image.www.ipros.com/public/product/image/600/2000331235/IPROS31366560678415915313.jpeg?w=280&h=280)



