Ground investigation | Re-evaluation of the cost of ground bearing capacity assessment for factory battery storage container uneven load measures.
Ground investigation
Review excessive reinforcement work and significantly reduce construction costs! Maintain safety with a second opinion on ground bearing capacity evaluation to prevent uneven loading.
We will achieve significant cost reductions in construction by eliminating excessive reinforcement work. The container-type storage batteries introduced on the factory site tend to incur uneven loads due to the consolidation of internal devices, and high-cost steel pipe piles or deep ground improvement are often specified due to overly conservative safety factors. GeoTech provides second opinions on other companies' surveys and simple penetration data, and conducts precise ground bearing capacity re-evaluations through plate load tests on the foundation bearing surface. By calculating the true allowable bearing capacity and ground reaction coefficient of shallow ground from multi-stage loading data on the actual pressure surface, we scientifically verify the risk of differential settlement under uneven loads. We eliminate unnecessary reinforcement specifications based on objective physical evidence and demonstrate the validity of changing to direct foundation specifications such as mat foundations. This significantly reduces excess foundation reinforcement costs and piling processes, supporting the optimization of capital investment costs and early operational commencement. High-quality reports that comply with public standards also facilitate smooth review of confirmation applications, balancing economic efficiency and safety.
Inquire About This Product
basic information
In accordance with JGS1521 (Method for Plate Load Test on Ground), a multi-stage load test will be conducted using a rigid steel loading plate with a diameter of 300mm and a hydraulic jack at the foundation bearing surface. A hydraulic backhoe and other devices will be used as reaction devices, and by gradually applying actual loads, the ultimate bearing capacity, long-term and short-term allowable bearing capacities, as well as the ground reaction coefficient (K value) and deformation coefficient (E value) will be accurately derived. The amount of settlement will be automatically collected and recorded using a high-precision displacement meter, eliminating speculative calculations that could lead to excessive design. Equipment calibrated under the company's ISO9001 quality standards will be used, and qualified specialists will complete detailed re-evaluation analysis and report preparation.
Price information
Please contact us.
Delivery Time
Applications/Examples of results
It is ideal for a second opinion diagnosis when excessive ground reinforcement costs are anticipated during the installation of container-type storage batteries at factories and business sites. It can be utilized to reduce construction costs by avoiding excessive piling and deep improvement, and to validate the allowable bearing pressure of floor slabs and mat foundations. Additionally, it contributes widely to the rationalization and cost optimization of industrial energy infrastructure investments by re-evaluating the settlement risk of substations and cubicle foundations with uneven weight distribution, verifying the ground bearing capacity of existing factory vacant spaces, and submitting change evidence to review and inspection agencies.
catalog(3)
Download All Catalogs
Company information
-








![Dry Wave Retractable Indoor Clothes Drying Rack [Good Design Award Winner]](https://image.www.ipros.com/public/product/image/600/2000331235/IPROS31366560678415915313.jpeg?w=280&h=280)

![[Proposal] Bird Damage Prevention (Wire Type) Altima Bird Prevention Wire](https://image.www.ipros.com/public/product/image/2032865/IPROS2629637137718331190.jpg?w=280&h=280)