S-i Method | Ground Reinforcement Work | Ensuring Reliable Bearing Capacity Directly Linked to Survey Data
Ground reinforcement work
Direct calculation of allowable bearing capacity from SWS and ram soundings test values. We support reliable structural design with clear technical basis and digital management.
To ensure the structural safety of buildings, it is essential to select appropriate reinforcement work based on accurate evaluations of ground investigation data and equivalent N-values. Constructing foundations with insufficient ground strength poses serious deterioration risks, such as structural distortion and wall damage due to uneven settlement. GeoTech Corporation's "Σ-i Method" utilizes the results of SWS tests and automatic ram sounding tests to calculate a rational allowable bearing capacity, providing a pile-type ground reinforcement technology. The four excavation blades at the tip of the steel pipe and the integrally formed spiral wings demonstrate exceptional penetration thrust, allowing for smooth access to the target bearing layer and ensuring strong tip bearing capacity. The rotation-driven insertion method, which does not use cement-based solidifying materials, achieves zero construction-generated soil (excess soil), significantly reducing disposal costs and on-site processing expenses. It has obtained GBR performance certification from the Japan Architectural Comprehensive Testing Institute, and we provide highly transparent and reliable construction through digital construction data management.
Inquire About This Product
basic information
The Σ-i construction method is a reliable technical specification that has obtained the Architectural Technical Performance Certification from the Japan Building Disaster Prevention Association (GBRC Performance Certification No. 10-13 Rev. 2). The main shaft diameter standards range from φ89.1 mm to φ165.2 mm, and the tip spiral wing diameter is available in a lineup from φ270 mm to φ400 mm. The maximum construction depth from the ground surface can accommodate up to 130 times the main shaft diameter. Applicable ground types include sandy soil (including gravelly soil) and clayey soil. Objective allowable bearing capacity calculations can be made from the converted N values of SWS tests and dynamic cone penetration tests.
Price information
Delivery Time
Applications/Examples of results
This construction method is optimal for small-scale buildings such as single-family homes, multi-family residences, and stores that are three stories or fewer, have a height of 13 meters or less, and a total floor area of 1,500 square meters or less (for single-story buildings, 3,000 square meters or less). It also accommodates foundation reinforcement for retaining wall structures with a height of 3.5 meters or less. Since it allows for design calculations directly linked to ground investigation data such as SWS tests, it is widely used at sites that want to clarify the basis for building confirmation applications and structural calculations, as well as to achieve rational and economical foundation reinforcement while minimizing excessive design.