We achieve ground reinforcement that supports stable factory operations through reliable support capacity calculations based on survey data.
In factory facilities, high structural safety is required to prevent differential settlement of buildings due to vibrations and heavy loads from large machinery. If the foundation is laid without sufficient ground strength, it can lead to distortion of the structure and issues with the floor surface, potentially causing production line stoppages and increased repair costs. The Σ-i method supports the establishment of a stable foundation for factories through rational allowable bearing capacity calculations based on ground investigation data. 【Application Scenarios】 - Reinforcement of floor surfaces in factories installing large machinery and heavy equipment - Foundation reinforcement in areas manufacturing precision instruments that are susceptible to vibrations - Piling into reliable support layers during the construction of new factories 【Benefits of Implementation】 - Structural design based on clear technical foundations derived from investigation data - Reduction of soil displacement and cost savings through rotary insertion methods - High transparency in construction quality through digital construction data management
Inquire About This Product
basic information
【Features】 - Direct calculation of allowable bearing capacity from converted N values of SWS tests and ram soundings - Strong end bearing capacity provided by four excavation blades at the tip of the steel pipe and integrally formed spiral wings - Zero generation of construction soil through a rotary insertion method that does not use cement-based solidifying materials - Technical specifications certified by the General Incorporated Foundation Japan Building Comprehensive Testing Institute (GBRC) - High transparency in construction through a digital construction data management system 【Our Strengths】 Geotech is an engineering company that provides a one-stop service for all ground-related tasks, from ground surveys to reinforcement design and construction, as well as differential settlement corrections. With extensive experience and reliable technology, we support the stable future of our customers' factories.
Price information
Delivery Time
Applications/Examples of results
This construction method is optimal for small-scale buildings such as single-family homes, multi-family residences, and stores that are three stories or less, have a height of 13 meters or less, and a total floor area of 1,500 square meters or less (for single-story buildings, 3,000 square meters or less). It also accommodates foundation reinforcement for retaining wall structures with a height of 3.5 meters or less. Since it allows for design calculations directly linked to ground investigation data such as SWS tests, it is widely used at sites that aim for clear justification in building confirmation applications and structural calculations, as well as for rational and economical foundation reinforcement that minimizes excessive design.
catalog(4)
Download All Catalogs
Company information
-