Disaster prevention measures: Ensure stable power supply for buildings! Prevent water intrusion!
In public facilities, the safety and long-term durability of buildings are required for infrastructure maintenance. In particular, the power supply entry point of underground exterior walls significantly affects the risk of flooding during disasters! It is the most critical construction area for ensuring the safety of power supply to buildings. In conventional methods, complex waterproofing treatments and cumbersome piping connection work on-site have been major factors in prolonging construction periods. Pipe-in-Sleeve (abbreviated as PIS) simplifies on-site work by prefabricating PVC sleeves and FEP pipes in the factory, contributing to shorter construction periods while ensuring a stable power supply for buildings and playing a significant role in maintaining infrastructure during disasters. 【Target Facilities】 * General public facilities * Hospitals and welfare facilities * Residential facilities (high-rise and medium/small-scale apartments, etc.) * Transportation infrastructure facilities (railways, airports, highways, etc.) 【Target Applications】 * Underground beams/exterior wall penetration points (underground penetration/power cable entry) <Implementation Effects> * Disaster response: Maintaining a stable power supply for buildings * Labor saving (reducing the burden on workers) * Shortening construction periods * For details, please request a catalog from "Contact Us" or view the PDF data from "Download."
Inquire About This Product
Related Videos
basic information
<Specifications> ●Waterproof performance test value (smooth inner pipe) 0.1MPa×72 hours (This product does not guarantee complete waterproofing.) ●Composition - Sleeve material: Rigid polyvinyl chloride pipe (JIS K 6741) VU or VP - Sleeve penetration pipe: Underground buried electric wire protection pipe, Furukawa Electric Co., Ltd. Eflex (or flame-retardant Eflex) - Sealing material: Curing waterproof material filled in 2 locations ↓↓↓↓↓↓■Why is the waterproof performance of the pipe-in-sleeve set to "3 days"?■↓↓↓↓↓↓ ◆Local governments state that "the depth of flooding due to floods is 1-3m, and the duration of flooding is generally half a day to 1 day, but it may be 1 to 3 days depending on the location." ◆Emergency power supply systems in hospitals and other facilities are recommended to operate continuously for "more than 72 hours (3 days)" according to laws and guidelines. ◆The time until the restoration of lifelines during a disaster and the supply of relief supplies is assumed to be 72 hours. ◆Time limit for rescue activities: The time when the survival rate is said to drop sharply for rescues from collapsed buildings is within "72 hours (the golden 72 hours)."
Price range
Delivery Time
Applications/Examples of results
*R2.6 Publication of the National Transportation and Infrastructure Bureau "Guidelines for Flood Prevention Measures for Electrical Equipment in Buildings" *R3.4 Japan Sewerage New Technology Foundation "Promotion of Waterproofing (Final Version)" The adoption of ●●● steel pipes is rapidly increasing in the related construction work! <Public Works / Adoption Records Excerpt> (Statistics from January to June 2026) - Osaka Prefecture ●● City) Construction of communication facilities due to expansion - Shizuoka Prefecture ●● City) Electrical equipment construction for ●● District Center in FY 2027 - Kyoto Prefecture ●● City) Electrical equipment construction related to the new building of ●● City Hospital (Section 1) - Kanagawa Prefecture ●● City) Electrical equipment construction for the expansion of ●● Elementary School building No. 1 - ●● Prefecture Civil Engineering Department Maintenance Division) Electrical equipment construction for the new construction of (tentative name) ●● Special Support School - Aichi Prefecture ●● City) Integrated redevelopment project for ●● City School Lunch Center (For other records, please download the separate adoption record sheet) Due to the recent shortage of construction workers and skilled labor, there are materials/methods that allow for "easy construction," but some overlook waterproof performance, leading to an increasing trend in water leakage problems at power supply entry points in recent years. To prevent large-scale repair work due to water leakage accidents in the future, we advocate the adoption of pipe-in-sleeve systems that combine both "labor-saving at construction sites" and "ensuring the waterproof performance of buildings."
Detailed information
Line up(16)
| Model number | overview |
|---|---|
| PIS30U(PIS30NU) | Conduit Pipe / FEP-30 (Flame Retardant FEP-30) * Rigid PVC Pipe VU-50 |
| PIS40U(PIS40NU) | Conduit Pipe / FEP-40 (Flame Retardant FEP-40) * Rigid Polyvinyl Chloride Pipe VU-65 |
| PIS50U(PIS50NU) | Through pipe / FEP-50 (flame-retardant FEP-50) * Rigid PVC pipe VU-75 |
| PIS65U(PIS65NU) | Conduit Pipe / FEP-65 (Flame Retardant FEP-65) * Rigid PVC Pipe VU-100 |
| PIS80U(PIS80NU) | Through pipe / FEP-80 (flame-retardant FEP-80) * Rigid PVC pipe VU-125 |
| PIS100U(PIS100NU) | Conduit Pipe / FEP-100 (Flame Retardant FEP-100) * Rigid PVC Pipe VU-150 |
| PIS125U(PIS125NU) | Conduit pipe / FEP-125 (flame-retardant FEP-125) * Rigid PVC pipe VU-200 |
| PIS150U(PIS150NU) | Conduit pipe / FEP-150 (flame-retardant FEP-150) * Rigid PVC pipe VU-250 |
| PIS30P(PIS30NP) | Conduit pipe / FEP-30 (flame-retardant FEP-30) * Rigid PVC pipe VP-50 |
| PIS40P(PIS40NP) | Through pipe / FEP-40 (flame-retardant FEP-40) * Rigid PVC pipe VP-65 |
| PIS50P(PIS50NP) | Conduit pipe / FEP-50 (flame-retardant FEP-50) * Rigid PVC pipe VP-75 |
| PIS65P(PIS65NP) | Through pipe / FEP-65 (flame-retardant FEP-65) * Rigid polyvinyl chloride pipe VP-100 |
| PIS80P(PIS80NP) | Conduit pipe / FEP-80 (Flame-retardant FEP-80) * Rigid PVC pipe VP-125 |
| PIS100P(PIS100NP) | Conduit pipe / FEP-100 (Flame-retardant FEP-100) * Rigid polyvinyl chloride pipe VP-150 |
| PIS125P(PIS125NP) | Conduit Pipe / FEP-125 (Flame Retardant FEP-125) * Rigid Polyvinyl Chloride Pipe VP-200 |
| PIS150P(PIS150NP) | Conduit pipe / FEP-150 (Flame-retardant FEP-150) * Rigid PVC pipe VP-250 |
catalog(8)
Download All Catalogs
CAD data(48)
| Model number | overview | File |
|---|---|---|
| 【Drawing (VU-50)】Pipe in Sleeve: PIS30U (Flame Retardant PIS30NU) | Pipe in Sleeve: Through Flex FP-30 (Flame Retardant Flex NFP-30) / JIS PVC Sleeve VU-50 |
|
| 【Drawing (VU-50)】Pipe in Sleeve: PIS30U (Flame Retardant PIS30NU) | Pipe in Sleeve: Through Flex FP-30 (Flame Retardant Flex NFP-30) / JIS PVC Sleeve VU-50 |
|
| 【Drawing (VU-50)】Pipe in Sleeve: PIS30U (Flame Retardant PIS30NU) | Pipe in Sleeve: Through Flex FP-30 (Flame Retardant Flex NFP-30) / JIS PVC Sleeve VU-50 |
|
| 【Drawing (VU-65)】Pipe in Sleeve: PIS40U (Flame-retardant PIS40NU) | Pipe in Sleeve: Through Flex FP-40 (Flame Retardant Flex NFP-40) / JIS PVC Sleeve VU-65 |
|
| 【Drawing (VU-65)】Pipe in Sleeve: PIS40U (Flame-retardant PIS40NU) | Pipe in Sleeve: Through Flex FP-40 (Flame Retardant Flex NFP-40) / JIS PVC Sleeve VU-65 |
|
| 【Drawing (VU-65)】Pipe in Sleeve: PIS40U (Flame-retardant PIS40NU) | Pipe in Sleeve: Through Flex FP-40 (Flame Retardant Flex NFP-40) / JIS PVC Sleeve VU-65 |
|
| 【Drawing (VU-75)】Pipe in Sleeve: PIS50U (Flame Retardant PIS50NU) | Pipe in Sleeve: Through Flex FP-50 (Flame Retardant Flex NFP-50) / JIS PVC Sleeve VU-75 |
|
| 【Drawing (VU-75)】Pipe in Sleeve: PIS50U (Flame Retardant PIS50NU) | Pipe in Sleeve: Through Flex FP-50 (Flame Retardant Flex NFP-50) / JIS PVC Sleeve VU-75 |
|
| 【Drawing (VU-75)】Pipe in Sleeve: PIS50U (Flame Retardant PIS50NU) | Pipe in Sleeve: Through Flex FP-50 (Flame Retardant Flex NFP-50) / JIS PVC Sleeve VU-75 |
|
| 【Drawing (VU-100)】Pipe in Sleeve: PIS65U (Flame Retardant PIS65NU) | Pipe in Sleeve: Through E-Flex FP-65 (Flame Retardant E-Flex NFP-65) / JIS PVC Sleeve VU-100 |
|
| 【Drawing (VU-100)】Pipe in Sleeve: PIS65U (Flame Retardant PIS65NU) | Pipe in Sleeve: Through E-Flex FP-65 (Flame Retardant E-Flex NFP-65) / JIS PVC Sleeve VU-100 |
|
| 【Drawing (VU-100)】Pipe in Sleeve: PIS65U (Flame Retardant PIS65NU) | Pipe in Sleeve: Through E-Flex FP-65 (Flame Retardant E-Flex NFP-65) / JIS PVC Sleeve VU-100 |
|
| 【Drawing (VU-125)】Pipe in Sleeve: PIS80U (Flame Retardant PIS80NU) | Pipe in Sleeve: Through Flex FP-80 (Flame Retardant Flex NFP-80) / JIS PVC Sleeve VU-125 |
|
| 【Drawing (VU-125)】Pipe in Sleeve: PIS80U (Flame Retardant PIS80NU) | Pipe in Sleeve: Through Flex FP-80 (Flame Retardant Flex NFP-80) / JIS PVC Sleeve VU-125 |
|
| 【Drawing (VU-125)】Pipe in Sleeve: PIS80U (Flame Retardant PIS80NU) | Pipe in Sleeve: Through Flex FP-80 (Flame Retardant Flex NFP-80) / JIS PVC Sleeve VU-125 |
|
| 【Drawing (VU-150)】Pipe in Sleeve: PIS100U (Flame Retardant PIS100NU) | Pipe in Sleeve: Through Flex FP-100 (Flame Retardant Flex NFP-100) / JIS PVC Sleeve VU-150 |
|
| 【Drawing (VU-150)】Pipe in Sleeve: PIS100U (Flame Retardant PIS100NU) | Pipe in Sleeve: Through Flex FP-100 (Flame Retardant Flex NFP-100) / JIS PVC Sleeve VU-150 |
|
| 【Drawing (VU-150)】Pipe in Sleeve: PIS100U (Flame Retardant PIS100NU) | Pipe in Sleeve: Through Flex FP-100 (Flame Retardant Flex NFP-100) / JIS PVC Sleeve VU-150 |
|
| 【Drawing (VP-50)】Pipe in Sleeve: PIS30P (Flame Retardant PIS30NP) | Pipe in Sleeve: Through Flex FP-30 (Flame Retardant Flex NFP-30) / JIS PVC Sleeve VP-50 |
|
| 【Drawing (VP-50)】Pipe in Sleeve: PIS30P (Flame Retardant PIS30NP) | Pipe in Sleeve: Through Flex FP-30 (Flame Retardant Flex NFP-30) / JIS PVC Sleeve VP-50 |
|
| 【Drawing (VP-50)】Pipe in Sleeve: PIS30P (Flame Retardant PIS30NP) | Pipe in Sleeve: Through Flex FP-30 (Flame Retardant Flex NFP-30) / JIS PVC Sleeve VP-50 |
|
| 【Drawing (VP-65)】Pipe in Sleeve: PIS40P (Flame Retardant PIS40NP) | Pipe in Sleeve: Through Flex FP-40 (Flame Retardant Flex NFP-40) / JIS PVC Sleeve VP-65 |
|
| 【Drawing (VP-65)】Pipe in Sleeve: PIS40P (Flame Retardant PIS40NP) | Pipe in Sleeve: Through Flex FP-40 (Flame Retardant Flex NFP-40) / JIS PVC Sleeve VP-65 |
|
| 【Drawing (VP-65)】Pipe in Sleeve: PIS40P (Flame Retardant PIS40NP) | Pipe in Sleeve: Through Flex FP-40 (Flame Retardant Flex NFP-40) / JIS PVC Sleeve VP-65 |
|
| 【Drawing (VP-75)】Pipe in Sleeve: PIS50P (Flame Retardant PIS50NP) | Pipe in Sleeve: Through E-Flex FP-50 (Flame Retardant E-Flex NFP-50) / JIS PVC Sleeve VP-75 |
|
| 【Drawing (VP-75)】Pipe in Sleeve: PIS50P (Flame Retardant PIS50NP) | Pipe in Sleeve: Through E-Flex FP-50 (Flame Retardant E-Flex NFP-50) / JIS PVC Sleeve VP-75 |
|
| 【Drawing (VP-75)】Pipe in Sleeve: PIS50P (Flame Retardant PIS50NP) | Pipe in Sleeve: Through E-Flex FP-50 (Flame Retardant E-Flex NFP-50) / JIS PVC Sleeve VP-75 |
|
| 【Drawing (VP-100)】Pipe in Sleeve: PIS65P (Flame Retardant PIS65NP) | Pipe in Sleeve: Through E-Flex FP-65 (Flame Retardant E-Flex NFP-65) / JIS PVC Sleeve VP-100 |
|
| 【Drawing (VP-100)】Pipe in Sleeve: PIS65P (Flame Retardant PIS65NP) | Pipe in Sleeve: Through E-Flex FP-65 (Flame Retardant E-Flex NFP-65) / JIS PVC Sleeve VP-100 |
|
| 【Drawing (VP-100)】Pipe in Sleeve: PIS65P (Flame Retardant PIS65NP) | Pipe in Sleeve: Through E-Flex FP-65 (Flame Retardant E-Flex NFP-65) / JIS PVC Sleeve VP-100 |
|
| 【Drawing (VP-125)】Pipe in Sleeve: PIS80P (Flame Retardant PIS80NP) | Pipe in Sleeve: Through Flex FP-80 (Flame Retardant Flex NFP-80) / JIS PVC Sleeve VP-125 |
|
| 【Drawing (VP-125)】Pipe in Sleeve: PIS80P (Flame Retardant PIS80NP) | Pipe in Sleeve: Through Flex FP-80 (Flame Retardant Flex NFP-80) / JIS PVC Sleeve VP-125 |
|
| 【Drawing (VP-125)】Pipe in Sleeve: PIS80P (Flame Retardant PIS80NP) | Pipe in Sleeve: Through Flex FP-80 (Flame Retardant Flex NFP-80) / JIS PVC Sleeve VP-125 |
|
| 【Drawing (VP-150)】Pipe in Sleeve: PIS100P (Flame Retardant PIS100NP) | Pipe in Sleeve: Through Flex FP-100 (Flame Retardant Flex NFP-100) / JIS PVC Sleeve VP-150 |
|
| 【Drawing (VP-150)】Pipe in Sleeve: PIS100P (Flame Retardant PIS100NP) | Pipe in Sleeve: Through Flex FP-100 (Flame Retardant Flex NFP-100) / JIS PVC Sleeve VP-150 |
|
| 【Drawing (VP-150)】Pipe in Sleeve: PIS100P (Flame Retardant PIS100NP) | Pipe in Sleeve: Through Flex FP-100 (Flame Retardant Flex NFP-100) / JIS PVC Sleeve VP-150 |
|
| 【Drawing (VU-200)】Pipe in Sleeve: PIS125U (Flame-retardant PIS125NU) | Pipe in Sleeve: Through Flex FP-125 (Flame Retardant Flex NFP-125) / JIS PVC Sleeve VU-200 |
|
| 【Drawing (VU-200)】Pipe in Sleeve: PIS125U (Flame-retardant PIS125NU) | Pipe in Sleeve: Through Flex FP-125 (Flame Retardant Flex NFP-125) / JIS PVC Sleeve VU-200 |
|
| 【Drawing (VU-200)】Pipe in Sleeve: PIS125U (Flame-retardant PIS125NU) | Pipe in Sleeve: Through Flex FP-125 (Flame Retardant Flex NFP-125) / JIS PVC Sleeve VU-200 |
|
| 【Drawing (VU-250)】Pipe in Sleeve: PIS150U (Flame-retardant PIS150NU) | Pipe in Sleeve: Through Flex FP-150 (Flame Retardant Flex NFP-150) / JIS PVC Sleeve VU-250 |
|
| 【Drawing (VU-250)】Pipe in Sleeve: PIS150U (Flame-retardant PIS150NU) | Pipe in Sleeve: Through Flex FP-150 (Flame Retardant Flex NFP-150) / JIS PVC Sleeve VU-250 |
|
| 【Drawing (VU-250)】Pipe in Sleeve: PIS150U (Flame-retardant PIS150NU) | Pipe in Sleeve: Through Flex FP-150 (Flame Retardant Flex NFP-150) / JIS PVC Sleeve VU-250 |
|
| 【Drawing (VP-200)】Pipe in Sleeve: PIS125P (Flame Retardant PIS125NP) | Pipe in Sleeve: Through Flex FP-125 (Flame Retardant Flex NFP-125) / JIS PVC Sleeve VP-200 |
|
| 【Drawing (VP-200)】Pipe in Sleeve: PIS125P (Flame Retardant PIS125NP) | Pipe in Sleeve: Through Flex FP-125 (Flame Retardant Flex NFP-125) / JIS PVC Sleeve VP-200 |
|
| 【Drawing (VP-200)】Pipe in Sleeve: PIS125P (Flame Retardant PIS125NP) | Pipe in Sleeve: Through Flex FP-125 (Flame Retardant Flex NFP-125) / JIS PVC Sleeve VP-200 |
|
| 【Drawing (VP-250)】Pipe in Sleeve: PIS150P (Flame Retardant PIS150NP) | Pipe in Sleeve: Through Flex FP-150 (Flame Retardant Flex NFP-150) / JIS PVC Sleeve VP-250 |
|
| 【Drawing (VP-250)】Pipe in Sleeve: PIS150P (Flame Retardant PIS150NP) | Pipe in Sleeve: Through Flex FP-150 (Flame Retardant Flex NFP-150) / JIS PVC Sleeve VP-250 |
|
| 【Drawing (VP-250)】Pipe in Sleeve: PIS150P (Flame Retardant PIS150NP) | Pipe in Sleeve: Through Flex FP-150 (Flame Retardant Flex NFP-150) / JIS PVC Sleeve VP-250 |
|
Company information
A manufacturer specialized in planning, design, and engineering. We focus on product development to solve various issues at construction sites, providing innovative, cutting-edge, and ecological products. Please feel free to contact us.












![[Adoption Results] Waterproof Sleeve for Underground Exterior Walls / Pipe-in-Sleeve TM](https://image.www.ipros.com/public/product/image/2092961/IPROS17264123785335376528.png?w=280&h=280)


![Flood prevention measures & waterproofing construction Tome Taro [NETIS] - Typhoon measures and disaster response.](https://image.www.ipros.com/public/product/image/132/2001068478/IPROS42727678704078489352.png?w=280&h=280)
![Non-drying polyolefin-based one-component waterproofing putty "Tometaro" [NETIS registered]](https://image.www.ipros.com/public/product/image/ceb/2001411481/IPROS09042418105265901879.png?w=280&h=280)
![Waterproofing measures for penetrations using non-hardening water stop material Tome Taro (R) [NETIS]](https://image.www.ipros.com/public/product/image/2001511731/IPROS18432506726232385893.jpg?w=280&h=280)