Structural calculations for garage boxes considering lateral earth pressure can be performed.
We will perform stability calculations and member calculations for a reinforced concrete garage box (underground parking) on the basement level. Calculations can be conducted considering lateral earth pressure. The side walls will be calculated as a culvert structure, while the rear wall will be calculated as a fixed slab on all four sides to determine the member section forces.
Inquire About This Product
basic information
■Applicable Standards and References Building Standards Act, Building Standards Act Enforcement Order, and related notifications "Reinforced Concrete Structural Calculation Standards and Commentary" February 2010 (Architectural Institute of Japan) "Reinforced Concrete Structural Calculation Data Collection" January 2002 (Architectural Institute of Japan) "Building Foundation Structural Design Standards and Commentary" October 2001 (Architectural Institute of Japan) ■Functions and Limitations - Design of underground garages in reinforced concrete structures. - Capability to perform long-term and short-term stability calculations and member calculations. - Soil pressure calculations can be performed with stairs installed parallel to the garage box. - It is possible to individually input surface load on the left side, right side, and rear of the garage box. - Design loads can be specified as imposed loads on the roof and floor. - The roof, floor, and side walls are calculated as culvert structures, while the rear wall is calculated as a fixed slab on all four sides to determine member section forces. - Stability calculations check for sliding, overturning, and soil bearing capacity. - Both lateral soil pressure and eccentric soil pressure (either left or right) can be considered. - Both stability calculations and member calculations can be performed for long-term and short-term loads.
Price information
New purchase cost: 110,000 yen (including tax) (Includes first-year subscription fee) Subscription fee (from the second year onwards): 33,000 yen (including tax)
Price range
P3
Delivery Time
P1
Applications/Examples of results
We will perform stability calculations and member calculations for a reinforced concrete garage box (underground parking) on the first basement level. Calculations considering lateral earth pressure can be conducted. The side walls will be calculated as a culvert structure, while the back wall will be calculated as a slab with fixed edges to determine the member section forces.
catalog(1)
Download All CatalogsCompany information
Our company is widely used by civil engineering firms for the development and sale of civil engineering design software. We provide comprehensive support for your business, including retaining walls, slopes, temporary structures, bridges, and cost estimation. Please feel free to contact us if you have any requests.