Centrifuge stops for unknown reasons!? Introducing examples of equipment malfunctions and noise countermeasures!
We would like to introduce a case of equipment malfunction that occurred at Research Institute C of a certain pharmaceutical manufacturer. "We want to operate the centrifuge continuously for 8 hours, but the machine stops at night." "Even though it's a newly installed analytical device, for some reason, there is damage to the internal circuit board." We requested each equipment manufacturer to investigate the causes of these malfunctions and prevent recurrence, but since the cause could not be identified, we were asked to provide the best solution. We considered the possibility that high-frequency noise was the cause of the malfunctions and proposed the introduction of high-frequency noise countermeasure products that could be implemented at a lower cost than a stabilized power supply. We provided a trial unit of the product. [Overview] ■ Client: Research Institute C of a certain pharmaceutical manufacturer ■ Request details - Please investigate why the equipment is malfunctioning. - Is the introduction of a stabilized power supply the best choice? Please provide your opinion. ■ Results - Proposed the introduction of high-frequency noise countermeasure products that could be implemented at a lower cost than a stabilized power supply and provided a trial unit. - The high-frequency noise countermeasures resolved the issues, achieving stable operation of the research equipment.
Inquire About This Product
basic information
【Point】 It is important to implement measures suitable for the causes of disturbances that worsen the power supply environment. *For more details, please refer to the PDF document or feel free to contact us.*
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
catalog(1)
Download All CatalogsCompany information
Our company is a manufacturer that develops and produces noise control products, including the "Noise Cut Transformer." Additionally, we provide consulting on noise control through our "Noise Trouble Consultation Room," established in 1983. We handle approximately 3,000 consultations annually and have a track record of resolving nearly 100% of the issues. Our products range from large-scale items for major plants and intelligent buildings to small electronic devices for medical equipment and measuring instruments, and they are used in various fields. Through these activities and technical research in the EMC field, we have received broad and high evaluations from both public research institutions and the industrial sector.