We will achieve heatstroke prevention, dust control, and energy conservation with "non-wetting mist."
"Non-wetting mist" semi-dry fog lowers the surrounding temperature through evaporative cooling. We are currently offering a catalog of cooling products for energy-saving air conditioning in factories and warehouses, as well as peak-cutting for air conditioners. Inquiries for product demonstrations are also being well received! ■ 'COOLJetter Series' A cooling device that effectively prevents heatstroke among employees, utilizing mist and a fan. It cools by blowing "non-wetting mist" with a fan. ■ 'Cool Mist System' A cooling system that can be used semi-permanently as part of a structure. It generates "non-wetting mist" from a header and cools the surroundings through evaporative cooling. Automatic control operation is possible with temperature and humidity sensors and various timers. ■ 'COOLSAVE-D' A cooling unit for outdoor units of air conditioners and refrigeration machines. During the hot summer months, it lowers the temperature around the outdoor unit using mist. By increasing the heat exchange rate, it is possible to reduce power consumption. *For more details, please refer to the catalog. Feel free to contact us with any inquiries.
Inquire About This Product
basic information
【Series Name】COOLJetter 【Series Features】Sprays non-wetting mist*1 and disperses cool air over a wide area using a blower fan, an energy-saving cooling device (fog fan/mist fan). 【Series Name】Cool Mist System 【Series Features】Sprays non-wetting mist*1 from a header installed at building entrances, sending cool air to the surrounding area, an energy-saving cooling system (dry-type mist). 【Series Name】Outdoor Unit Cooling System 【Series Features】Sprays fine mist from a header attached to the outdoor unit, cooling the intake of the outdoor unit with an outdoor unit cooling unit. *1. Semi-dry fog (fine mist with an average particle diameter of 10-30μm)
Price range
Delivery Time
Applications/Examples of results
【Examples of Use】 [Cooling for People] @Heat countermeasures in work areas, break rooms, waiting areas, and corridors in factories and warehouses. [Cooling for Objects] @Shortening manufacturing cycles through high-temperature object cooling. @Extending the lifespan of refractory facilities through cooling. @Peak cutting for air conditioning. [Dust Suppression] @Dust countermeasures at recycling centers and similar locations. @Dust control on sports fields and other areas. [Humidification] @Static electricity countermeasures in dry environments. @Dryness countermeasures aimed at protecting throat mucosa in hospital facilities. [Deodorization] @Deodorization in zoos, cattle barns, stables, pig farms, chicken coops, and waste collection sites. [Production] @Production in amusement parks, parks, event venues, and promotions.
Detailed information
-
Heat stroke prevention and dust control measures for workers [Series Name] COOLJetter - Effective for heat stroke prevention for those working outdoors or in large spaces, as well as for dust suppression in areas with high dust levels.
-
Heat and dust control measures for large open spaces [Series Name] Cool Mist System - Effective for heat and dust control in large open spaces without partitions, such as outdoors or semi-outdoors. - Can also be utilized as an electrostatic countermeasure in dry factories.
-
Peak Cut for Air Conditioners [Series Name] COOLSAVE-D - Efficiently cools the outdoor units of air conditioners and refrigerators - Reduces summer electricity consumption by 10%, achieving peak cut
-
Cooling with the vaporization heat of the non-wetting mist "Semi-Dry Fog" - Fine mist "Semi-Dry Fog" with an average particle diameter of 10-30μm is sprayed, cooling the surrounding temperature by 3-5°C through this vaporization heat. - It is possible to cool the area without wetting the surroundings due to the extremely fine mist. * * Depends on the weather conditions and installation layout during use. Please contact us for details.
-
[Model Number] CLJ-CSA - Diffuses non-wet mist with fan airflow for cooling - Mobile cart type - Equipped with oscillation function
-
[Model Number] CLJ-590 - Distributes non-wet mist with fan airflow for cooling - Large type - Equivalent to IP55 - Oscillation function available (optional)
-
[Model Number Name] CLJ-C590A - Diffuses a non-wet mist with the fan's airflow for cooling - Large type - Mobile cart type
catalog(1)
Download All CatalogsCompany information
Leveraging our extensive experience cultivated over many years and innovative spray technology, we provide precise and high-performance solutions. With a unique approach that utilizes the power of mist, we support our customers' businesses to contribute to the efficiency of manufacturing sites, optimization of energy, and environmental protection. ■ Examples of Applications 【Electronics】Precision cleaning, etching, developing, humidification/cooling, static electricity prevention 【Pollution Prevention】Exhaust gas cooling, neutralization/cleaning, defoaming/deodorizing, dust removal, VOC suppression 【Steel & Non-Ferrous】Cooling, scale removal, surface treatment, rust prevention 【Food】Cleaning, humidity control/cooling, disinfection, coating, fermentation promotion, moisture prevention 【Paper Pulp】Cleaning, spraying, defoaming, trimming, wastewater treatment, humidity management 【Vehicles】Pre-paint humidification, cleaning/cooling, air blowing, rust prevention/dust removal 【Textiles】Humidification/cleaning, oiling, static electricity prevention 【Agriculture & Livestock】Watering, sterilization, pest control, germination promotion, temperature and humidity management 【Plastics & Rubber】Cooling, release, surface finishing, molding assistance 【Shipbuilding & Marine】Fire prevention, hull cleaning, corrosion prevention, rust prevention 【Medical & Pharmaceutical】Hygiene management, humidification, sterilization, clean room humidity management 【Mining】Dust suppression, humidity/cooling management, defoaming, etc.