We conducted a heat transfer analysis of an internal radiation container composed of multiple radiation zones.
**Case Overview** ■Product Name: Femap Thermal ■Analysis: Thermal Analysis ■Industry: Other In this analysis example, a thermal radiation transfer analysis within a container composed of multiple radiation zones was conducted. In this case, the radiation zones consist of three areas: the interior of the container, which includes the heat source, heat receiving surface, and inner wall; the space between the inner and outer walls; and the area from the outer wall to the environment. The calculation of the form factor is known to take time due to the exhaustive pairwise calculations between element surfaces, resulting in a large matrix size. Femap Thermal utilizes the Hemicube method with OpenGL to process the time-consuming form factor calculations quickly. Additionally, with a dedicated interface for thermal analysis, it is easy to set up radiation settings even for models with multiple enclosures. □ For other functions and details, please refer to the catalog.
Inquire About This Product
basic information
This is an introduction to a case study of radiative heat transfer analysis within a container using Femap Thermal.
Price information
******
Delivery Time
Applications/Examples of results
For more details, please contact us.
catalog(1)
Download All CatalogsCompany information
At N.S.T, we provide a variety of support to comprehensively assist our customers in better manufacturing, ranging from the provision of diverse analysis tools to their utilization methods and contract analysis. Our company offers truly usable numerical analysis tools and seamlessly supports the introduction and operation of these tools by leveraging the know-how gained through our extensive experience in the field of numerical analysis.