Manometer
● It is a water column type pressure gauge. ● Because it is a direct-reading type, it achieves the highest accuracy from an engineering perspective. ● The structure is also extremely simple, and if used correctly, there are no failures.
Inquire About This Product
basic information
■Standard Type (KMA Type) Manometer - With cover and drain outlet - Measurement range: 2.5 kPa, 4.5 kPa, 9 kPa. Custom larger sizes are also available. - For copper tube installation. A dedicated adapter (sold separately) allows for the attachment of vinyl tubes as well. ■Light Type (L Type) Manometer - Measurement range: 2.5 kPa, 4.5 kPa - For vinyl tube installation
Price information
-
Delivery Time
Applications/Examples of results
- For pressure measurement inside the tank and duct - To check the timing for backwashing the bag filter and replacing the filter (to check the filter resistance) - Installed at the inlet and outlet of the cyclone and at the bend of the air transport piping to check pressure loss
Company information
The efficiency and rationalization of the transportation or transfer methods for powders, granules, liquids, and gases, as well as environmental improvement, are essential for modern corporate management. Since our establishment in 1969, Fluid Industry has consistently engaged in this field. These products are supplied based on reliable theories born from relentless research and the manufacturing experience of over a thousand powder and granule fluid plants, earning us recognition from our clients for our unique products designed with a human touch. Moving forward, Fluid Industry will continue to provide satisfaction along with our equipment, based on mobility and reliability, to all our clients.