1~34 item / All 34 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~34 item / All 34 items
● Pressing the button sends a call signal (16Hz) through the line. ● While the call signal is being sent, it can be confirmed by listening through the receiver. ● When the call signal is received, it is indicated by an electronic sound and the illumination of the call lamp. ● The volume of the electronic sound can be switched based on settings. ● The volume of the transmitter and receiver can be switched using a switch. Pressing the monitor button lights up the monitor lamp, allowing for line monitoring.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● It can be used with 2-wire and 4-wire telephone lines. ● You can activate the speakers of all telephones and call any desired party using voice calling for conversation. ● You can activate the speakers of all telephones and broadcast messages simultaneously. ● Line monitoring can be done using the built-in speaker.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe offer flexible solutions designed for efficiency, accommodating a wide range of capacities from large to small, including telephone devices that enable centralized operations. Automatic telephone ■ For more details, please contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration◆Rapid and Reliable Information Transmission from Various Locations within the Facility◆ In the vast area encompassing plant facilities, substations, and construction sites, a paging system enables workers to quickly and reliably confirm communications. 【Main Features】 ◆1. Group Call Intercom Commands and calls can be made simultaneously from any handset. The called party can respond using the nearest handset. ◆2. Group Broadcasting Simultaneous broadcasting can be performed using the handsets. ◆3. Conference Call After a group call, several people can engage in simultaneous intercom conversations. ◆4. Options Automatic telephone lines, shared telephone lines, and intercom lines can be accommodated together. ◆5. Others Remote control allows for simultaneous group calls, intercom conversations, and broadcasts from a distance.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTouch operations on the display screen allow for the selection of various lines and call control. Touch panel centralized telephone device.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Main Functions■□■ ■1. Selection of Network Stations [1] Individual selection [2] Group call [3] Group selection (with preset memory function) ■2. Calling Network Stations - Select from the following methods for each station [1] Group call method [2] Select call method (up to 8 groups of call sounds can be specified) ■3. Calling from Network Stations - Select from the following methods for each station [1] Group call [2] Select call (up to 8 groups of call sounds can be specified) ■4. Talkie Sounds Sends chimes, alert sounds, or comments as talkie sounds to network stations. Up to 5 types of talkie sound sources (each 8 seconds long) can be registered. ■5. Confirmation of Group Communication When a request for confirmation response (sending comments) for group communication is made to network stations, the results will be displayed based on whether a response is received. ■6. Communication Handset type or headset type
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationEstablished for the purpose of ensuring safety and guiding evacuation in the event of sudden emergencies such as major earthquakes or unauthorized intrusions for outdoor workers at airports and similar locations. 【Main Functions】 ◆1. Voice Reporting - Mass reporting function - Group reporting function (up to 30 groups) - Individual reporting function (90 reporting terminals) ◆2. Fixed Messages - Capacity: Up to 30 messages, maximum message length of 30 seconds ◆3. System Functions - Reporting operation status confirmation function: Displays the operational status of the terminal and the reporting device during reporting - Reporting monitor function: Allows monitoring of the reporting content through speakers - Capacity of reporting operation devices: Up to 6 units ◆4. Reporting Chime Sound Function ◆5. Automatic Reporting ◆6. Maintenance Functions - Time synchronization function: Can synchronize time with a time server (separately) - System operational status display - Fault notification function: Displays the installation status, ongoing reporting, speaker output failures, etc., on the monitor screen - Network check function: Supports network monitoring - Virus protection: Virus definition file distribution function - Power outage measures: Equipped with UPS (uninterruptible power supply) to operate for about 10 minutes during a power outage
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA compact combined telephone device that allows various types of command telephones and business telephones to be handled collectively on a small operation desk. Since the dedicated space for telephones is reduced, operability is also improved. Additionally, the operation desks can be distributed and shared in appropriate locations, which improves the previously fixed arrangement of telephones and enables the establishment of an efficient telephone system.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA collective telephone device that accommodates various types of dedicated telephone lines, various automatic lines, and NTT subscriber telephone lines into a PHS-compatible control device, using PHS mobile terminals for the endpoints.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■It consists of a monitoring transmission and reception device deployed at the business office and a remote monitoring device for distribution lines deployed at the distribution substation. ■Monitoring Transmission and Reception Device (Office Device) - It connects to input/output devices such as general urban distribution automation devices, backup VDTs, internal and external alarm devices, and automatic reporting devices. - It can support up to 20 remote monitoring devices for distribution lines. ■Remote Monitoring Device for Distribution Lines (Substation Device) - By expanding the circuit board, it can monitor the status of up to 3 banks and 18 feeders, and control monitoring of up to 6 routes with 360 child devices.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationConference calls using individual telephones can be realized over an IP network with an IP voice transmission/VoIP adapter.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■This is a power adapter specifically designed for individual call phones using commercial power supply, converting an AC100V input into a stabilized DC6V output. ■It has a built-in rechargeable battery for backup, allowing it to be used as an uninterruptible power supply during AC power outages. (Over 1 hour of talk time)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■After an accident occurs on the distribution line, the accident situation will be reported to the pre-registered email addresses of mobile devices, etc. ■By reporting the details of the accident via email, the situation can be confirmed promptly. ■Emails are sent to multiple recipients almost simultaneously, enabling quick notification of the accident to all relevant parties. ■It is possible to selectively set reporting actions for accidents at specific substations, providing excellent flexibility. ■The settings for reporting recipients can be easily configured with just the ON/OFF of checkboxes, making operation simple. ■There is a convenient feature that allows reporting actions to be triggered only outside of working hours, on holidays, and during public holidays (*), eliminating the need for cumbersome daily settings or registrations. *Regarding the setting of public holidays, due to amendments to the Public Holiday Law, prior registration in a human system will be required.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■ Inherits functions from F-11,12 and F-21,22, allowing for updates and expansions of existing lines. ■ Allows for line monitoring via internal speakers. ■ The ringtone for incoming calls can be selected from four electronic sound patterns. ■ The caller's ringtone can be confirmed with a ringback tone. ■ It is possible to set the incoming call alert to a voice call. ■ The volume during transmission and reception can be switched with a switch.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBy using it in combination with high-voltage automatic circuit breakers and high-voltage ground fault direction indicators, it is possible to separate the fault point and reduce the scope of power outages on distribution lines where intermittent ground fault incidents and instantaneous ground fault incidents occur repeatedly without operating the feeder circuit breaker. Since it can be used with high-voltage automatic sectionalizers, there is no need for special pole-mounted reclosing protection devices (recloser high-voltage devices). Additionally, due to its small and lightweight design, it is easy to relocate and install along with portable high-voltage ground fault indicators.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationGenerally, at the boundary point of safety responsibility for high-voltage consumers, it is stipulated to install SOG-type high-voltage automatic branch circuit breakers to prevent accidents occurring within the high-voltage consumer's premises from affecting the distribution lines. This device is used in combination with the SOG-type high-voltage automatic branch circuit breaker to detect ground faults and overcurrent incidents occurring within the consumer's premises by monitoring zero-sequence current and zero-sequence voltage.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn cases where short-circuit accidents occur near the ends of long distribution lines or after insulation transformers, and cannot be protected by the protective relays of distribution substations, this device is installed and used along the distribution line. This device is used in combination with high-voltage equipment (recloser high-voltage equipment). Additionally, by installing it near the boundary between urban and suburban areas, it also has the effect of preventing the impact of accidents occurring in the suburbs from spreading to urban areas.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■This device is used in combination with a manual switch that has a built-in ground fault direction detector. ■In the event of a ground fault accident occurring on the distribution line, this device determines which direction (power side or load side) the ground fault is occurring from the installation point of the device and transmits that information to the business office via remote monitoring. ■By installing this device, it becomes possible to grasp the ground fault direction based on the installation point, which reduces the scope of accident investigation, thereby facilitating labor-saving in accident recovery and simultaneously shortening power outage time. ■The device itself is also equipped with a ground fault direction indicator (MagSign), allowing for visibility of the ground fault direction from the ground on-site. ■Since the device is equipped with a backup battery, it can transmit accident information to the business office even during a power outage caused by an accident.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■Sensor System: Measures the operating status of the equipment (voltage values, current values, etc.) and detects failure and abnormal conditions. ■Transmission System: Transmits change data from the sensor system to the display and control system, and conveys data from the display and control system back to the sensor system. ■Display and Control System: Accumulates data collected from each sensor, performs display and analysis, and also controls system function changes.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn general, high-voltage distribution lines are equipped with multiple high-voltage automatic sectionalizers (hereinafter referred to as sectionalizers) along the route, and a time-delayed transfer method is adopted to enable the separation and reduction of outage sections during distribution line accidents and to allow power transmission to healthy outage sections. This device is a remote-controlled substation device used in combination with these sectionalizers.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis device is installed at branching points such as distribution terminals to configure branching lines for four-wire telephone lines, allowing for the branching connection of multiple four-wire telephone terminal devices.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCompared to the conventional balanced circuit type hybrid circuit configuration, the occurrence of singing (howling) is suppressed even in the multi-branch configuration of the 2W circuit, allowing for stable call quality.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■This system is designed to accurately grasp disaster prevention information necessary for the safe operation of trains and to enable rapid response in emergencies. It continuously collects measurement data from meteorological observation devices installed along the railway, including water levels, earthquakes, rainfall, wind speed, rail temperature, snowfall, and detection of events such as scouring, falling rocks, landslides, avalanches, and bridge girders, using communication lines. This data is displayed on screens at command centers and maintenance districts. When the data reaches pre-set regulatory or alarm values, the system automatically determines this and alerts with a buzzer and display. ■The system consists of two components: a real-time operation system that collects measurement data from meteorological observation devices, makes regulatory judgments, and notifies alarms on display devices; and a data storage and analysis system that sends the collected measurement data to a data storage and analysis server for data preservation and analysis, as well as access to meteorological data from weather information providers.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■This is a device that implements 48 circuits of resistive attenuators to ensure the matching of voice levels between four-wire telephone lines (4WS, 4WR) during relay connections between terminal stations. ■The attenuation can be set to a range of 0 to 15.5 dB (in 0.5 dB steps) by combining attenuation values of 0.5, 1, 2, 4, and 8 dB.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■By using two of this device in conjunction with a switching device, operation in both active and standby modes is possible. ■Signal Device ・Ambient Temperature: 0℃ to +40℃ ・Relative Humidity: 60±30% ・Input Voltage: DC48V±10% ・Rated Output: 30W ■Switching Device ・Ambient Temperature: 0℃ to +40℃ ・Relative Humidity: 60±30% ・Input Voltage: DC48V±10% ・RINGER Input Circuit: 2 circuits
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■It can be used with various types of transmission terminals such as short transmission, optical transmission, and cable PCM. ■Connection to the transmission terminal is made via 4W/SS(DL)/SR(RG) terminals. ■It has a plug-in type circuit board that can be detached and attached for each line (12 channels), making maintenance easy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■The amplification circuit can compensate for bidirectional (up/down) line loss (up to 20dB in 1dB steps). ■The amplitude correction circuit allows for the correction of amplitude characteristics in both directions (up/down), with settings available in four stages, enabling a maximum correction of +12dB for an amplitude corresponding to a frequency of 3300Hz (equivalent to the press signal frequency) at 1kHz. ■The input and output impedance of the line is compatible with either 600Ω or 370Ω (configurable). ■The device can be powered by AC100V, DC24V, or DC48V. ■For AC100V power supply, rechargeable batteries can be installed (optional). ■The structure is a standard rack 1U unit (height 50mm), so it does not take up much space.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe main transmission path has been converted from coaxial and metal cables to optical fiber, and the digitization of the lines is progressing. This device multiplexes and transmits 23 existing analog important lines over a 1.5M service line of the optical transmission path. ■□■Features■□■ ■Up to 23 voice lines can be configured from the exchange to subscriber repeater lines. ■Implementation types for voice circuits and others can be specified on a per-line basis. ■The digital circuits are compatible with the 1.5M service of telecommunications operators. ■This device is constructed with a dual configuration for the power supply and digital line sections.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■It can be used with various types of transmission terminals such as short-distance transmission, optical transmission, and cable PCM. ■Connection with the transmission terminal is made via 4W, SS(DL)/SR(RG) terminals. ■It has a plug-in type circuit board that can be detached for each line, making maintenance easy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWhen relaying a telephone line to connect multiple terminals (such as telephones or modulation/demodulation devices) in a branch connection, it is possible to perform branching connections of four-wire or two-wire lines at the branching point.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a new type of two-wire telephone line bi-directional amplifier that employs an echo canceller. It is suitable for long-distance communication measures for various telephone lines such as command telephone lines, along-line telephone lines, automatic telephone lines, and telespi lines.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■It has a one-message recording function, allowing playback of broadcasts when absent. ■It has a relay function that reduces volume variation due to installation distance. ■It has an amplification function, which minimizes volume variation caused by metallic loss over distance.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■This is a network telephone device installed at the headquarters and branch offices to facilitate smooth business communications between the headquarters, branch offices, and key stations. ■The call operation desk at the headquarters can be distributed across various departments within the station, and by connecting to a PBX, it can be handled with regular telephones. ■Branch offices can communicate with the headquarters from any telephone within the company through the connection of button telephone devices to the station lines.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■□■Features■□■ ■Up to 60 sub-units can be called and communicated with. ■Switching operations between the main operator and the sub-operator allow for both split and collective operation. ■When selecting a sub-unit, contact output can be performed on the sub-unit side, enabling integration with other systems. ■Connection to the transport device is easily achievable as it adopts a 4-wire system. ■Operational switching is possible through external contact input on the main unit side, allowing for integration with other systems.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration