The locations where electrical fires occur are said to be in distribution boards and control panels, where wiring is concentrated. Since distribution boards and control panels are responsible for the power and control of buildings and equipment, damage from a fire can require significant time and cost for recovery. Our flame sensor instantly detects flames (ultraviolet light) generated by a fire, and with the use of CO2 extinguishing agents, it enables not only rapid initial extinguishing but also allows for quick recovery due to the complete absence of contamination risk. Safety measures for distribution boards and control panels are often overlooked, so please consider this opportunity. 【Features】 ■ Early detection of flames generated inside the panel through ultraviolet detection ■ Rapid extinguishing possible with CO2 extinguishing agents ■ No risk of contamination from extinguishing agents ■ Can be retrofitted to DIN rails ■ Selection of the number of connected cylinders according to the panel's capacity
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn recent years, there have been damages caused by fires at waste disposal facilities, which have become a social issue. Many of these incidents are due to the ignition and explosion of mobile batteries and lithium-ion batteries mixed in with combustible waste. Our flame sensor for belt conveyors can detect flames and sparks with high sensitivity and at an early stage, helping to minimize damage caused by fires. The SKH086EEP is designed to be directly installed on belt conveyors and crushers, featuring 【heat resistance】【vibration resistance】【dustproof】【fully waterproof functionality】. 【Features】 ■ Can be directly installed on belt conveyors and crushers ■ Usable in harsh environments such as dust and high temperatures ■ Early detection of flames to prevent fire-related accidents ■ User-friendly open collector output that can be linked with alarm devices *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFM certification refers to a unique standard operated by an insurance company based in the United States, which tests and evaluates the safety and performance of products from all aspects, including hardware and software. Sensors that pass specific criteria are awarded the "FM Approved" certification mark, proving the high reliability of the product. Our company has cleared this rigorous testing and has been approved as the world's first non-explosion-proof ultraviolet detection flame sensor. (As of October 2024) Obtaining this certification among flame sensors, which are considered to have fewer product standards, further ensures the quality and safety of the product.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe SKH047M is a flame sensor that can detect flames equivalent to that of a lighter from a distance of 10 meters using a UV detection method. It instantly detects the ultraviolet rays emitted by flames from lighters or matches ignited by arsonists. Our flame sensor can be used outdoors due to its unique sunlight separation technology. It supports relay output, allowing it to drive alarm buzzers, rotating lights, voice synthesis units, and more. 【Features】 ■ Compliant with dustproof and waterproof standards (IP64) ■ High sensitivity for flame detection ■ Easy-to-change detection timer settings using DIP switches *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe heavy machinery flame sensor SKH086M was developed for the early detection of fires originating from the engine room of heavy machinery. It detects ultraviolet rays emitted from flames generated in the engine room and alerts the operator with an alarm. To withstand the operating environment of heavy machinery, it is equipped with heat resistance, vibration resistance, dustproof, and fully waterproof features. It supports wireless output (920MHz), reducing installation hassle. *Note: A separate dedicated wireless receiver SKH086RDM is required to use the wireless function. 【Features】 ■ Can be directly installed in the engine room of heavy machinery ■ Usable in harsh environments such as dust and high temperatures ■ Prevents accidents caused by fires through early flame detection ■ Detects ultraviolet rays emitted from flames and alerts the operator with an alarm *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFactory fires are often caused by ignition or sparks from electrical systems (electrical fires), with the occurrence points typically being within distribution boards and control panels. To facilitate the early detection of fires within these boards, SKH089 has been developed. This device consolidates ultraviolet detection technology into a compact body, allowing for the high-sensitivity detection of flames and sparks that occur within the panels. Additionally, it can detect the diffuse reflection of ultraviolet light generated within the panels, enabling flexible installation layouts. 【Features】 ■ High-sensitivity detection of flames and sparks (ultraviolet) originating from distribution boards ■ Detection of diffuse reflection of ultraviolet light ■ Compact body & direct installation on DIN rails ■ Equipped with relay c contact output