1~8 item / All 8 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~8 item / All 8 items
In our basic training for power generation equipment, we focus on boilers, turbines, generators, and environmental equipment, learning about the roles of each device and the connections within the system. Experienced instructors provide clear explanations. With comprehensive texts and a variety of supplementary materials, you can also use them for review. Additionally, not only do we have lectures, but you can also observe cut models, utilizing old power plant equipment as training cut models, which adds a different level of impact. 【Examples of outcomes from the training】 ■ Understanding the roles and functions of key equipment in thermal power plants ■ Understanding the structure of key equipment down to the internal components ■ Systematically understanding the connections between key equipment in thermal power plants *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur driving operation simulator training can significantly improve operators' driving skills in a short period of time. Instructors who are well-versed in driving operations provide clear guidance on the points of operation and monitoring tailored to the operator's level, drawing from their own experiences. You can choose a simulator model that matches your equipment. Additionally, if desired, it is also possible to combine pre-training (classroom learning) before the actual training. 【Features】 ■ Repeated learning until you are satisfied ■ Experience learning with a sense of realism from over 100 accident occurrence items of your choice ■ We propose training items and schedules that meet your needs *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company has provided reliable and accurate performance management to many users of denitrification systems, enabling continuous operation of units by minimizing the impact on GAH. As a method for accurately measuring low concentration NH3 at the outlet of the denitrification system, we have adopted a sampling method adapted to the environment at the outlet, which differs from JIS standards. We conduct NH3 sampling at the same point more than twice to prevent sampling errors and improve the accuracy of absolute measurements. Additionally, we hold training sessions on denitrification performance operations. For more details, please visit our website. *For more information, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTraditionally, equipment updates have been carried out based on recommendations from manufacturers' residual life assessments. However, with our high-precision residual life diagnostics, it is now possible to extend the timing for equipment updates and regular inspections. In the residual life assessment, we use a pre-established master curve to determine the life consumption rate from the values of damage parameters and evaluate the remaining life. Additionally, we manage and conduct residual life diagnostics for boiler equipment at China Electric Power's thermal power plants in a comprehensive manner. [Possible Areas for Residual Life Diagnostics] ■ Equipment: Boiler equipment (2.25Cr-1Mo steel) ■ Diagnostic Areas - Large diameter pipes (main steam pipe, reheat steam pipe) - Pipe supports, pipe racks - Boiler tubes ■ Evaluation Methods - Void area ratio method - M parameter method - Grain deformation method (base material) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Do you have any concerns regarding steam turbine degradation diagnosis, such as wanting to know the lifespan of the car chamber or measuring the depth of scratches?" Our company conducts degradation diagnosis for steam turbine equipment. For the base material of the main valve, remaining life diagnosis is possible using a master curve, and we perform replica sampling and microscopic observation of void conditions. Please contact us if you need our services. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe offer an e-learning course titled "Fundamentals of Thermal Power Generation" for those who want to learn more about thermal power generation, including questions like "What is thermal power generation?" and "What are the structures of boilers, turbines, and generators?" The course provides clear explanations focusing on the fundamentals of technology, covering an overview of thermal power generation, boilers and auxiliary equipment, and operational procedures of thermal power plants. With a computer and internet access, you can learn anytime, anywhere. We also provide supplementary texts to assist your learning. 【Course Content】 ■ Overview of Thermal Power Generation ■ Boilers and Auxiliary Equipment ■ Steam Turbines and Auxiliary Equipment ■ Generators and Electrical Equipment ■ Plant Control Systems *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce our e-learning course "Combined Cycle Power Generation - Basic Course." This course provides a clear explanation of the mechanisms of combined cycle power generation, types of gas turbines, and the structure of generators. Additionally, the supplementary text is a full-color document consisting of 82 pages that outlines the content of the e-learning course, allowing you to study anytime and anywhere as long as you have a computer and internet access. [Learning Content] ■ Overview of Combined Cycle Power Generation ■ Features of Combined Cycle Power Generation ■ Gas Turbines ■ Heat Recovery Boilers ■ Steam Turbines and Generators ■ Control of Gas Turbines *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Power Engineering and Training Services Co., Ltd., we have developed a method for evaluating the integrity of threaded sections of implanted bolts using phased array ultrasonic testing technology in collaboration with a non-destructive testing company. By using a dedicated fixture, we can evaluate the integrity of the threaded sections qualitatively and quantitatively without extracting the implanted bolts. 【Features】 - Inspection can be performed at low cost without extracting the implanted bolts. - Stable images can be obtained using a dedicated fixture. - Long-term monitoring through the accumulation of digital data. - Accurate reproducibility of data using an encoder. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration