1~11 item / All 11 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~11 item / All 11 items
We would like to introduce our sample provision. The product name is TN315NY-T3 (for general turbid water treatment), which is a type that aggregates turbidity components. If the aggregation effect is not recognized, we will propose an appropriate coagulant or treatment method for that wastewater. The quantity and packaging are 100g/bag, and we will provide it to up to 10 companies per month. 【Overview】 ■ Product Name: TN315NY-T3 (for general turbid water treatment), a type that aggregates turbidity components ■ Quantity and Packaging: 100g/bag ■ Frequency: Up to 10 companies per month *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the treatment of wastewater containing PFOS and PFOA. The treatment method involves adding 1% NAC-01 to simulated raw water, stirring for 10 minutes, then adding 0.05% TN315NY-T3, performing strong stirring for 1 minute and weak stirring for 2 minutes, and finally filtering the supernatant through 5A filter paper and sending it to the Japan Food Analysis Center for analysis. The results showed that the raw water had a pH of 6.5 with PFOS and PFOA levels at 0.00058 mg/L, while the treated water had a pH of 7.0 with no detection of PFOS and PFOA. 【Treatment Method】 ■ Add 1% NAC-01 to simulated raw water and stir for 10 minutes ■ Add 0.05% TN315NY-T3, perform strong stirring for 1 minute and weak stirring for 2 minutes ■ Filter the supernatant through 5A filter paper and send the water to the Japan Food Analysis Center for analysis *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the analysis test results for water containing PFOS and PFOA. The analysis test items are perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), and the method used is solid-phase extraction - liquid chromatography - mass spectrometry. The result is 0.00058 mg/L. 【Analysis Test Results】 ■ Analysis Test Items ・Perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) ■ Result: 0.00058 mg/L ■ Method: Solid-phase extraction - liquid chromatography - mass spectrometry *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the analysis test results of Super Nami Treatment Water. The analysis test items are Perfluorooctane sulfonic acid (PFOS) and Perfluorooctanoic acid (PFOA), with the method being solid-phase extraction - liquid chromatography - mass spectrometry. The results showed no detection, with a quantification limit of 0.000005 mg/L. 【Analysis Test Results】 ■ Analysis Test Items ・Perfluorooctane sulfonic acid (PFOS) and Perfluorooctanoic acid (PFOA) ■ Results: Not detected ■ Quantification Limit: 0.000005 mg/L ■ Method: Solid-phase extraction - liquid chromatography - mass spectrometry *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to present the test results of the coagulation treatment of hexavalent chromium-containing wastewater from an industrial waste disposal site using our inorganic powder coagulant, "Super Namit." 500 ppm of "TN315CK" was added to the raw water, followed by strong stirring for 1 minute and weak stirring for 2 minutes. The supernatant was then filtered through rayon non-woven fabric with a pore size of 20 μm, and the filtered water was used for measurement. As a result, it was found that it is possible to reduce the hexavalent chromium concentration to below the environmental standard value of 0.05 mg/L. 【Treatment Conditions】 - 500 ppm of "TN315CK" was added to the raw water, with strong stirring for 1 minute and weak stirring for 2 minutes. - The supernatant was filtered through rayon non-woven fabric with a pore size of 20 μm, and the filtered water was used for measurement. - The measurement of hexavalent chromium concentration was conducted using a pack test. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the test results of removing turbidity components and others through coagulation treatment using the inorganic powder coagulant "Super Namit." The treatment target is the mixed water from leachate at a landfill and boiler-related wastewater discharged from industrial waste treatment facility boiler equipment, which is stored in a retention pond. It was found that using "TN315NY-T5" allows for a significant reduction of turbidity components and others easily. 【Treatment Conditions】 - After adding "TN315NY-T5" at 500 ppm to the raw water, strong stirring (1000 rpm) was conducted for 1 minute, followed by weak stirring (200 rpm) for 2 minutes. - The supernatant was analyzed as treated water. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to present an overview of the results of treatment tests conducted using special adsorbents and the inorganic powder coagulant "Super Namit" for the wastewater from the fuel oil tanks of a thermal power plant. The concentrations of oil and COD components were lower than expected; however, after performing adsorption treatment with the special adsorbents "CS-05" and "NAC-01," we were able to easily reduce COD Mn and n-hexane extractable substances by using our product for coagulation treatment. We were able to obtain colorless and transparent treated water. 【Treatment Conditions】 ■ Added 0.3% of the special oil adsorbent CS-05 and stirred for 10 minutes. ■ Added 0.5% of the special powdered activated carbon "NAC-01" and stirred for 10 minutes, then added 500 ppm of "TN315NY-T3," stirring vigorously for 1 minute and gently for 2 minutes to form flocs. ■ Filtered this using ADVANTEC No.5A quantitative filter paper and requested analysis from a measurement certification facility. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to present the results of tests conducted on linen wash wastewater using the inorganic powder coagulant "Super Namit" for adsorption, coagulation, and decomposition coagulation treatment. By adding a pretreatment agent at 0.05% and the COD decomposer "NAS-01" at 0.05%, along with "TN315-T3" at 0.05%, we confirmed the formation of large flocs, resulting in a colorless and transparent solution that significantly reduces COD. It is believed that by passing this treated water through an activated carbon adsorption tower, it can be reduced to below the target COD value of 30 mg/L. [Experiment-1] ■ 0.25% and 0.5% of "NAC-01" were added to the raw water and stirred for 10 minutes. ■ Then, after adding 0.05% of "TN315NY-S1", strong stirring (1000 rpm) was performed for 1 minute, followed by weak stirring (200 rpm) for 2 minutes. ■ The supernatant was analyzed as treated water. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Fulvic acid" is a valuable organic acid extracted from peat, which is formed from organic matter such as plants and algae that existed on Earth over 100 million years ago. After a long period of time, this organic matter undergoes humification and is on the verge of becoming coal or oil, with about 0.2% being extracted. It has a chelating effect that finely ionizes minerals, increasing the absorption rate to a high value of 97%. It is said to have effects such as antibacterial action, promotion of enzyme activation, enhancement of plant growth, and deodorizing properties. 【Features】 ■ Antibacterial action ■ Promotion of enzyme activation ■ Deodorizing properties ■ Finely ionizes minerals to increase the absorption rate to a high value of 97% *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Super Namit" is an inorganic powder coagulant that forms flocs simply by adding a specified amount of the powder and stirring. It eliminates the need for conventional processes and equipment such as pre-dissolution and neutralization. It achieves a space-saving and low-cost wastewater treatment system. 【Features】 ■ Simple treatment by just adding ■ Applicable to a wide range of wastewater treatment ■ Suitable for source control measures ■ Fast floc settling and easy dewatering *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "TAF Series" is a paint that forms a glass coating by curing liquid materials at the temperatures we typically live in (room temperature range). It creates a very hard film that is resistant to scratches and has super hydrophobic properties, making it highly effective in preventing graffiti and posters. 【Features】 ■ Forms a very hard film that is resistant to scratches ■ Non-combustible, does not emit toxic gases during a fire ■ Resistant to acid rain and sea breeze *For more details, please download the PDF or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration