1~8 item / All 8 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us OnlineBefore making an inquiry
Download PDF1~8 item / All 8 items
A compact near-infrared analysis device that completes the component analysis of all solutions with just one unit. - By adopting a special optical system, analysis is possible regardless of the size of light scattering with this one unit. - Economical due to the use of commercially available test tubes. - After spectral measurement, it can seamlessly transition to chemical analysis. - Capable of rapid non-destructive analysis of multiple components simultaneously. - Spectrum acquisition via Bluetooth connection with mobile devices.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce various application examples of non-destructive component analysis devices using near-infrared spectroscopy. If you are having difficulties with data measurement or analysis tasks, please consult us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "USB Photo Mal" is a weak light measuring instrument that allows the transfer of photo mal control signals and measurement data using USB. It is equipped with a light sensor module that incorporates a high-sensitivity light sensor (photo mal) and signal processing circuitry. Weak light measurement can be performed with just one cable connection to a PC. 【Features】 ■ Measure and control weak light through the PC's USB port ■ Set sensitivity and measurement conditions via control signals ■ Output detection data (analog data) ■ Lightweight at 135g, compact housing *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "USB/RS232C Photon Counter" is a weak light measurement device that enables weak light measurement with just one cable connection to a PC. It connects directly to a PC via USB or RS232C cable for weak light measurement, transferring control signals and measurement data from the PC. 【Features】 ■ Measure and control weak light using the PC's USB or RS232C port ■ Built-in high-sensitivity light sensor (photomultiplier) and signal processing circuit ■ Set measurement time via control signals ■ Output detection data (count numbers) *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe S009 is a cell-insertion type ultra-wide range weak light measurement device. With a combination of a ND filter switching mechanism with a three-digit attenuation rate and a photon counter, measurements can be performed over an optical range of approximately nine digits. It is mainly used for applications such as "nozzle carryover measurement," which verifies the cleaning effect inside the nozzle using enzyme-based chemiluminescent liquids. 【Features】 ■ Compatible with cells for spectrophotometers ■ Custom cells and round petri dishes can also be accommodated upon request *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe M018-01 is a near-infrared (NIR) analysis light source that irradiates the measurement target with NIR and can determine near-infrared absorption from the diffusely reflected light. By inputting the light output into a spectroscopic device, non-destructive component analysis based on near-infrared absorption becomes possible. 【Features】 ■ Effective for low reflectance targets due to high-output lamps ■ Adjustable light output according to the measurement target ■ Achieves long lifespan and high stability through air cooling of the light source ■ Compact design with mounting holes for easy fixation to optical systems *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe M020-M023 is a compact near-infrared analysis device that can non-destructively analyze the structure and components of food, bio-materials, synthetic resins, and more through near-infrared light diffuse reflection and transmission methods. It features a built-in high-output light source, enabling high-sensitivity measurements in the near-infrared range. The reflection type is equipped with an optical system that allows dark field and diffuse reflection through dual-side illumination. The transmission type can perform transmission absorption measurements using a 10x10 cell. 【Features】 ■ Simple operation by just placing the measurement target on the light receiving window ■ Selection of FT-IR or FPI spectral modules based on the wavelength range *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe M011-02 is a component analyzer that non-destructively measures lipid components in fish and meat using near-infrared (NIR) light in the range of 640-1,050 nm. It can be connected to a PC or mobile device via wired (USB) or wireless (Bluetooth) methods, allowing for the acquisition of intensity information for each wavelength. The desired components are calculated from the first and second derivatives of the absorbance changes at each wavelength. 【Features】 ■ Compact and lightweight due to ultra-small sensors ■ Wireless connection with mobile devices via Bluetooth ■ Acquired data is output in CSV format, making it easy to edit and analyze on a PC ■ Calibration curve creation function necessary for component analysis is available as an option *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration