fin - メーカー・企業と製品の一覧

finの製品一覧

1~3 件を表示 / 全 3 件

表示件数

[Performance Evaluation] Standard Folding Fin for Pipe

Just wrap it around and stop it.

◎ Achieves more than double the heat dissipation performance with and without fins ◎ Improved emissivity due to increased surface area ◎ Significant reduction in fin replacement costs ◎ A wide variety of lineups, making performance evaluation easy due to retrofitting capability ◎ Demonstrates higher performance when used with vertical piping ◎ Effective even without TIM (thermal interface materials such as adhesives and thermal conductive sheets) ◎ Improved work efficiency due to retrofitting capability

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Proposal/Analysis Example] How to Prototype Performance Improvement Products for Heat Exchangers

We propose a method of installation that involves wrapping around the pipe from the outside! This can simply be expected to improve performance.

We received an inquiry stating, "We would like to prototype an improved version of the existing heat exchanger." As a solution, please consider "wrapping folding fins around the pipe." By wrapping fins around the pipe, the heat exchange surface area is increased, which can simply lead to improved performance. Since this installation method involves wrapping from the outside, it allows for performance verification with minimal effort added to the existing product. Additionally, for some products, it may be more space-efficient to procure only the fin parts rather than the entire pipe. [Case Summary] ■ Issue: We would like to prototype an improved version of the existing heat exchanger. ■ Proposed Solution: Consider wrapping folding fins around the pipe. *For more details, please refer to the PDF document or feel free to contact us.

  • Heat exchanger

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Technical Column] "Report on Joint Research Results Regarding Fin Contact Thermal Resistance"

Introduction to the contact thermal resistance of pipe and piping outer wrap folding fins!

In this column, we report excerpts from the results of collaborative research conducted with a professor from Mie University regarding the contact thermal resistance during the installation of externally wrapped folding fins on pipes. In this collaborative research, a heater was inserted into the center of a copper cylinder, and experiments were conducted under natural convection conditions with fins wrapped around it. By measuring various points, we evaluated the effectiveness of the fins, comparisons based on the method of securing the fins, and the effects of thermal conductive sheets. We encourage you to read it. *For more detailed information about the column, please refer to the related links. Feel free to contact us for further inquiries.*

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録