List of Air conditioning, heating, ventilation equipment products
- classification:Air conditioning, heating, ventilation equipment
7261~7290 item / All 7421 items
Since the construction-generated soil will be recycled on-site, the disposal costs for leftover soil and the costs for new purchases will be significantly reduced. 【Disaster Prevention】
- Special Construction Method
The Noto Reconstruction Office of the Ministry of Land, Infrastructure, Transport and Tourism has featured our 3D printer in the Nikkei newspaper.
The official X account of the Noto Reconstruction Office of the Ministry of Land, Infrastructure, Transport and Tourism and the Nihon Keizai Shimbun have published that our 3D printer has been adopted for the reconstruction of Noto. The official X account of the Noto Reconstruction Office introduces the use of our products in the restoration work of the Noto Expressway. Additionally, the Nihon Keizai Shimbun mentions that structures made with our products are being used for the restoration of roads damaged by the Noto Peninsula earthquake, and that the construction period can be shortened by about two weeks, so please take a look.
Contributing to the second stage of public infrastructure! Bringing public infrastructure development to the ground. A robust outdoor storage tank for hazardous materials capable of responding to the ...
- Water Treatment
A dual safety structure that allows control from -10 to 110℃ and includes a built-in temperature fuse. For the controller (for control) and for the protector (for overheating prevention).
- Automatic Control Equipment
A double safety structure with a fuse built in series in M2, used frequently as a safety device.
- Automatic Control Equipment
It is capable of controlling temperatures from -10 to 110℃ and comes with tab terminals for MQT8H. *For controller (control) protector (overheating prevention).
- Automatic Control Equipment
It is capable of controlling temperatures from -10 to 110℃ and comes with tab terminals for MQT8K. *For controller (control) protector (overheating prevention) use.
- Automatic Control Equipment
It has higher waterproofing and is more shock-resistant than a vinyl tube.
- Automatic Control Equipment
- Waterproofing work
It can control temperatures from -10 to 110℃ and can be used by inserting it into heating pads, etc. *For controller (control) protector (overheat prevention) use.
- Automatic Control Equipment
It is a low-cost, simple power sensor for liquid temperature measurement.
- Automatic Control Equipment
If the resistance value is known at a certain temperature, the temperature can be determined from the resistance value.
- Automatic Control Equipment
This is an introduction to the acquisition of standards for temperature power sensors and disc-type thermostats.
- Automatic Control Equipment
This is an introduction to terms such as differential (response) tolerance (tolerance).
- Automatic Control Equipment
Convenient for wiring with a flexible protective tube with DIN connector.
- Automatic Control Equipment
The model differs in the case of temperature power sensors and electronic thermostats.
- Automatic Control Equipment
The thermal control system consists of four elements: the user, the heated object, and others.
- Automatic Control Equipment
The upper part of the tank and the lid can be drilled to insert, and the part that enters the liquid tank is completely waterproof.
- Automatic Control Equipment
- Waterproofing work
Advanced products like TPS are first adopted in regions with a significant technological accumulation.
- Automatic Control Equipment
If it's cheap, high-performance, compact, and long-lasting, it will hit the market immediately, but that's not always the case.
- Automatic Control Equipment
The lead wire type is also available as a variation of MQT83P.
- Automatic Control Equipment
Due to manufacturing reasons, the display method of the thermostat as a controller is complicated.
- Automatic Control Equipment
The minimum current for ordinary contacts is 50mA, and below that, crossbar contacts will be used.
- Automatic Control Equipment
If the change in ambient temperature is slow, the thermostat can adequately keep up with the temperature changes.
- Automatic Control Equipment
Medium temperature power sensor "M2H" capable of controlling temperatures from 115 to 200℃.
- Automatic Control Equipment
In air and water, water is more effective at extracting heat from objects, so the thermal time constant is smaller.
- Automatic Control Equipment
When using in a DC voltage circuit, care must be taken regarding the wear of the contacts.
- Automatic Control Equipment
Medium temperature power sensor "M2HA" capable of controlling temperatures from 115 to 400℃.
- Automatic Control Equipment
The mechanical lifespan of the temperature power sensor is constrained when used under heavy load.
- Automatic Control Equipment
This is a manual reset standard disk thermostat. *For protector use only (for overheating prevention).
- Automatic Control Equipment
The contact capacity display of the temperature power sensor is shown with a margin against heat generation.
- Automatic Control Equipment
MQT11HV is ideal for remote operation using variable resistors, etc.
- Automatic Control Equipment
This is a self-resetting standard disk thermostat. *For use with protectors (for overheating prevention).
- Automatic Control Equipment
It is a rare 710°C temperature fuse housed in a ceramic cylindrical case.
- Automatic Control Equipment