The RES-P method for planar ground reinforcement, certified for performance by the Japan Building Disaster Prevention Association.
This is a type of piled raft foundation method that has obtained the "Building Technology Performance Certification (Performance Evaluation No. 04-02)" from the Japan Architectural Institute Foundation. It involves driving thin steel pipes into soft ground, enhancing the bearing capacity through the composite action of the ground and the pipes, and suppressing the settlement of the building. While it is similar in that the pipes are arranged in a pile-like manner, it is positioned as a surface improvement method compliant with the characteristics of being densely installed, which distinguishes it from traditional pile reinforcement. The design, construction, and supervision are centrally managed under the framework of the "Single-Family Residential Foundation Ground Reinforcement Research Group," ensuring a robust quality management system through the management guidance of Soil Design Office Co., Ltd.
Inquire About This Product
basic information
It is based on a design philosophy that shares the building load between the foundation and the pipes. The thin-walled steel pipes used have an outer diameter of 48.6 mm and a wall thickness of 2.4 mm, and they are treated for rust prevention to ensure long-term durability. The applicable ground types are cohesive soil and sandy soil, with a maximum reinforcement depth of up to 14 m. In the connection with the foundation, a design is introduced that prevents horizontal forces during an earthquake from being transmitted to the pipes by not integrating them with the foundation body, placing the head between the bottom of the excavation and the lower end of the discarded concrete. During construction, the pipes are driven in by rotary insertion using the pressure and rotational force of the insertion device, and the penetration depth and resistance at all locations are reliably recorded.
Price range
Delivery Time
Applications/Examples of results
It is optimal for reinforcing the foundation ground of small-scale buildings, boasting a rich track record of over 60,000 improvement projects to date. The applicable range is limited to buildings with up to three stories above ground, a height of 13 meters or less, and a total floor area of 1,500 m² or less. The foundation structure can be applied to slab foundations with a long-term design load of 80 kN/m² or less, or strip foundations with a load of 50 kN/m² or less. As practical examples of achievements, there are sites where no soil is generated due to non-excavation construction, eliminating disposal costs, sites that can be handed over to the next process immediately with zero curing time, and tight construction projects in narrow spaces or near retaining walls that leverage low vibration and low noise specifications, demonstrating outstanding advantages.
catalog(2)
Download All CatalogsCompany information
-


![[For Energy Facilities] RES-P Method Ground Reinforcement Work | Geotech](https://image.www.ipros.com/public/product/image/321794/IPROS14969689924364169768.png?w=280&h=280)




![Dry Wave Retractable Indoor Clothes Drying Rack [Good Design Award Winner]](https://image.www.ipros.com/public/product/image/600/2000331235/IPROS31366560678415915313.jpeg?w=280&h=280)

![[Proposal] Bird Damage Prevention (Wire Type) Altima Bird Prevention Wire](https://image.www.ipros.com/public/product/image/2032865/IPROS2629637137718331190.jpg?w=280&h=280)