DM Method | Ground Reinforcement with Small-Diameter Winged Steel Pipe Piles [Performance Certification]
DM method
Reinforcement of clay and sandy soil with steel pipe piles with advanced wing. High-performance reinforcement method corresponding to SWS equivalent N values of 5 to 15.
The DM method, established as a performance verification method for ground reinforcement, is a pile-type reinforcement technology that utilizes small-diameter steel pipes with end wings. The steel pipe tips are equipped with wings with diameter ratios of 3.0 and 3.5, demonstrating high applicability to both clayey and sandy soils within a converted N value range of 5 to 15 based on the SWS test (Screw Weight Penetration Test). Since the SWS converted N value can be directly utilized during the design phase, accurate planning and improved constructability according to ground conditions can be expected.
Inquire About This Product
basic information
Low Price The construction machinery and replacement size are very compact at φ101.6mm, providing excellent workability. Since the tip wings and steel pipes are bolted together, the welding process is significantly reduced. They can be transported while disassembled, allowing for efficient transportation. High Quality The tip wings are manufactured at a factory certified by the Minister of Land, Infrastructure, Transport and Tourism for the production of cast iron tip wings "FOD450A" used for rotary driven steel pipe piles. Our factory has quality control managers and certified welders on-site, ensuring a robust quality management system. Convenience Construction association members nationwide undertake DM method construction. As our products are made in-house, we can flexibly respond to various orders. Warranty With compliance to design and construction regulations and functional traceability of construction data, we can enroll in various insurance policies, providing peace of mind with our warranty.
Price range
Delivery Time
Applications/Examples of results
Applicable types of ground Foundation pile tip ground: sandy soil, clayey soil Maximum construction depth 130 times the main body axis diameter (up to 13.2m) from the construction ground surface Applicable buildings Buildings that satisfy all of the following conditions 1 to 4, as well as small-scale structures such as retaining walls and signs with a height of 3.5m or less: 1 Up to 3 stories above ground 2 Up to 13m in height 3 Eaves height of 9m or less 4 Total floor area of 500m2 or less
catalog(2)
Download All CatalogsCompany information
-







![Dry Wave Retractable Indoor Clothes Drying Rack [Good Design Award Winner]](https://image.www.ipros.com/public/product/image/600/2000331235/IPROS31366560678415915313.jpeg?w=280&h=280)

![[Proposal] Bird Damage Prevention (Wire Type) Altima Bird Prevention Wire](https://image.www.ipros.com/public/product/image/2032865/IPROS2629637137718331190.jpg?w=280&h=280)