The Elcometer 456 digital thickness gauge is sold in 170 countries and regions around the world. Please check out its diverse features that are not found in conventional thickness gauges.
☆Free Demo Unit Rental (2-week period)☆ We offer various probes for the Elcometer digital thickness gauge 456. Please choose according to your testing method and application. - Interchangeable probes for various shapes and applications - Inspection certificate and calibration standard foil included - Ergonomically designed for easy handling - Stable measurements over a wide temperature range ⋘《0–1,500μm 【Scale 1】》⋙ Accuracy: ±1–3% or ±2.5μm, whichever is greater Measurement range: 0–1,500μm Resolution: 0.1μm for 0–100μm, 1μm for 100–1,500μm For more detailed information, please check this page and the 'YouTube' video. *If Japanese is not displayed: After logging into YouTube, set "Language: Japanese, Location: Japan" from the account icon in the upper right corner of the screen to enable Japanese subtitles. Alternatively, you can select the language from "Settings" → "Subtitles" in the lower right corner of the video screen.
Inquire About This Product
basic information
Elcometer Ltd. was established in the UK in 1947. Since developing the world's first non-destructive coating thickness gauge, we have been selling and servicing coating inspection equipment, including thickness gauges, in over 120 countries and regions worldwide. We have obtained ISO 9000 and ISO 14001 certifications. 〖Applicable Standards〗 AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12, BS 5599, EN 13523-1, IMO MSC.215(82), IMO MSC.244(83), ISO 1461, ISO 19840, ISO 2063, ISO 2178, ISO 2360, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, JIS K 5600-1-7, NF T30-124, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32
Price range
P3
Delivery Time
Applications/Examples of results
【Eddy Current Probe】 This is for measuring insulating coatings applied to non-magnetic metal substrates (such as gold, silver, copper, aluminum, chromium, titanium, etc.). Use with the thickness gauge 456, which is designed for "non"-magnetic metals. (*Cannot be used with the thickness gauge designed for magnetic metals.) 〖Straight Probes〗 ■ Standard Straight Probe - Can measure coatings on both flat and curved surfaces. ■ Mini Probe - Ideal for measuring in hard-to-reach places and corners. ■ Thick Film Probe - Can measure coatings up to 31mm thick. 〖Scan Probes〗 ■ Standard Scan Probe - Allows continuous measurement over large areas without damaging the probe or coating. 〖L-Type Probes〗 ■ L-Type (Right Angle) Probe - Used for measurements in narrow spaces. ■ Mini L-Type Probe - Suitable for measuring corners and small surfaces inside narrow pipes. ■ 45° Angled Probe - Used for measuring in tight, hard-to-reach areas and complex locations. 〖Plug-Type Probes (PINIP)〗 ■ PINIP Probe - Can be integrated into a separate thickness gauge for one-handed measurement. ■ High-Temperature PINIP - Can measure the thickness of coatings on magnetic metal surfaces up to 250°C.
Detailed information
-
Straight Probe [Model Number] T456CN1S Probe Length: 45mm Minimum Clearance (Height): 85mm Minimum Target Diameter: 4mm 《0–1,500μm [Scale 1]》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement Range: 0–1,500μm Resolution: 0.1μm for 0–100μm, 1μm for 100–1,500μm
-
L-shaped Probe [Model Number] T456CN1R Probe Length: 45mm Minimum Clearance (Height): 28mm Minimum Target Diameter: 4mm 《0–1,500μm [Scale 1]》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement Range: 0–1,500μm Resolution: 0.1μm for 0–100μm, 1μm for 100–1,500μm
-
L-shaped Mini Probe [Model Number] T456CNM5R90A Probe Length: 45mm Minimum Clearance (Height): 16mm Minimum Target Diameter: 4mm 《0–1,500μm [Scale 1]》 Accuracy: ±1–3% or ±2.5μm, whichever is greater Measurement Range: 0–1,500μm Resolution: 0.1μm for 0–100μm, 1μm for 100–1,500μm
-
L-Type Mini Probe - Long Type [Model Number] T456CNM5R90E Probe Length: 400mm Minimum Height Clearance: 16mm Minimum Target Diameter: 4mm 《0 to 1,500μm [Scale 1]》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement Range: 0 to 1,500μm Resolution: 0.1μm for 0 to 100μm, 1μm for 100 to 1,500μm
-
Built-in PINIP Probe [Model Number] T456CN1P Minimum Height Clearance: 180mm Minimum Target Diameter: 4mm 《0–1,500μm [Scale 1]》 Accuracy: ±1–3% or ±2.5μm, whichever is greater Measurement Range: 0–1,500μm Resolution: 0.1μm for 0–100μm, 1μm for 100–1,500μm
-
Anodized Probe [Model Number] T456CN1AS Probe Length: 45mm Minimum Clearance (Height): 100mm Minimum Target Diameter: 4mm 《0–1,500μm [Scale 1]》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement Range: 0–1,500μm Resolution: 0.1μm for 0–100μm, 1μm for 100–1,500μm
Line up(7)
Model number | overview |
---|---|
T456CN1S | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm Straight probe Probe length: 45mm Minimum height clearance: 85mm Minimum target diameter: 4mm |
T456CN1R | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm L-shaped probe Probe length: 45mm Minimum height clearance: 28mm Minimum target diameter: 4mm |
T456CNM5R90A | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm L-shaped mini probe Probe length: 45mm Minimum height clearance: 16mm Minimum target diameter: 4mm |
T456CNM5R90E | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm L-shaped mini probe - Long type Probe length: 400mm Minimum height clearance: 16mm Minimum target diameter: 4mm |
T456CN1P | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm Built-in PINIP Minimum height clearance: 180mm Minimum target diameter: 4mm |
T456CF1P | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm Built-in PINIP probe Minimum height clearance: 170mm Minimum target diameter: 4mm |
T456CN1AS | 《0~1,500μm 【Scale 1】》 Accuracy: ±1–3% or ±2.5μm, whichever is larger Measurement range: 0–1,500μm Resolution: 0.1μm: 0–100μm, 1μm: 100–1,500μm Anodized probe Probe length: 45mm Minimum height clearance: 100mm Minimum target diameter: 4mm |
catalog(2)
Download All CatalogsCompany information
Elcometer, with a specialized team composed of cutting-edge production facilities and elite development engineers in the UK and Europe, has been leading the industry as a frontrunner in the fields of coating inspection, concrete testing, and metal detection. The globally renowned products of Elcometer are available in every region through sales offices in the UK, the US, Singapore, the Netherlands, France, and Germany, as well as through distributors around the world.