[Energy Saving Effect Measurement Case] Chiller for Clean Room Air Conditioning System
Power consumption decreased by 30% within two months after installation! Introducing the energy-saving effects of the refrigeration unit using the water reforming device "The Bio Water."
We would like to introduce a case study on the energy-saving effects of our clean room air conditioning system's refrigeration unit. A water conditioning device, The Bio Water, was installed in the cooling tower (350RT) water tank, and changes in water quality were measured, along with changes in the power consumption of the refrigeration unit's compressor. Additionally, we confirmed changes in the replacement cycle of the filters installed in the cooling water for production equipment. The power consumption of the refrigeration unit's compressor decreased by 30% two months after the installation of The Bio Water. This was due to the removal of scale in the cooling water piping circulating from the cooling tower to the refrigeration unit, resulting in a reduced load on the compressor and confirming the energy-saving effect. [Test Overview] ■ Test Location: Taichung City Precision Injection Molding Factory ■ BW Installation Date: November 14, 2018 - Installation of The Bio Water in the cooling tower ■ Test Period: November 14, 2018 - January 25, 2019 ■ Test Content: Measurement of energy-saving effects of the refrigeration unit in the clean room air conditioning system * The production equipment installed in the clean room includes injection molding machines and deposition devices. * For more details, please refer to the PDF document or feel free to contact us.
Inquire About This Product
basic information
【Field Test Overview Diagram】 ■ The refrigeration unit supplies chilled water to air conditioning systems by cycling the refrigerant through evaporation → compression → condensation → expansion. ■ The cooling tower circulates cooling water to cool and condense the high-temperature, high-pressure refrigerant gas that flows into the condenser. ■ When scale builds up inside the piping that circulates this cooling water, the heat transfer in the cooling water piping within the condenser deteriorates, reducing the condenser's condensation capacity. ■ The load on the refrigeration unit's compressor increases, leading to higher electricity consumption. *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during the PDF download is generated by Ipros Inc.'s AI.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
catalog(1)
Download All CatalogsCompany information

T.K.K.エボリューション (株式会社エランビタールは2022年4月1日より社名変更しました)
Our company was established in 2000 after becoming independent from a plumbing maintenance company with over 113 years of history. We focus on water quality improvement technology, addressing issues such as rust on the inner surfaces of water pipes and scale in heat exchangers. Under the corporate philosophy of "Sanpo Yoshi," we consistently provide optimal water environment solutions. *The section titled 'Reason for Interest' displayed during the PDF download is generated by Ipros Inc.'s AI.