Rheometer - Company Ranking(4 companyies in total)

Last Updated: Aggregation Period:Jul 09, 2025〜Aug 05, 2025
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
■Number of cylinder bodies: Single (Model F-1) or Twin (Model F-2) ■Cylinder body diameter: F-1: Ø9.55mm or Ø15mm, F-2: Ø15mm ■Load capacity: F-1: 25kN (Ø9.55) or 50kN (Ø15mm), F-2: 25kN ■Extrusion speed: 0.1 to 1500mm/min. ■Capillary die lineup: Length 0.2 to 50.8mm, diameter 0.5 to 2.095mm, with inflow angle or flat (180°) ■Test temperature: max. 400℃ ■Data processing device: Standard included (PC, dedicated software) ■Options: Die swell measurement, melt tension measurement, pipe length correction and Rabinovich correction processing software, automatic input software, elongational viscosity calculation processing software For other specifications, please refer to the catalog. <Reference Standards> JIS K 7199 (Testing method for flow characteristics of plastics using capillary rheometers and slit die rheometers) ISO 11443 With over 40 years of achievements and trust since the development of the first model, it has been adopted by many customers, including resin material manufacturers, for research and development and quality control purposes.
---

---

---
  1. Featured Products
    Capillary rheometer "Capilograph"Capillary rheometer "Capilograph"
    overview
    ■Number of cylinder bodies: Single (Model F-1) or Twin (Model F-2) ■Cylinder body diameter: F-1: Ø9.55mm or Ø15mm, F-2: Ø15mm ■Load capacity: F-1: 25kN (Ø9.55) or 50kN (Ø15mm), F-2: 25kN ■Extrusion speed: 0.1 to 1500mm/min. ■Capillary die lineup: Length 0.2 to 50.8mm, diameter 0.5 to 2.095mm, with inflow angle or flat (180°) ■Test temperature: max. 400℃ ■Data processing device: Standard included (PC, dedicated software) ■Options: Die swell measurement, melt tension measurement, pipe length correction and Rabinovich correction processing software, automatic input software, elongational viscosity calculation processing software For other specifications, please refer to the catalog. <Reference Standards> JIS K 7199 (Testing method for flow characteristics of plastics using capillary rheometers and slit die rheometers) ISO 11443
    Application/Performance example
    With over 40 years of achievements and trust since the development of the first model, it has been adopted by many customers, including resin material manufacturers, for research and development and quality control purposes.