Calibrator - Company Ranking(14 companyies in total)

Last Updated: Aggregation Period:Jul 16, 2025〜Aug 12, 2025
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
The ASL brand CTR2000 can measure in either 2-channel or 8-channel configurations. The probes can accommodate 4-wire or 3/4-wire types, allowing you to choose according to your needs. The included probes feature enhanced functionality to achieve high operability and low life costs. For example, there is a function to save calibration data in the main unit's memory. By simply connecting the probe to the connector, the specifications are instantly recognized, enabling data storage with the highest measurement accuracy. Additionally, it is possible to monitor the conditions of the surrounding environment during calibration. <Basic Specifications> - Accuracy: ±0.01℃ full range (4-wire platinum resistance thermometer) ±0.05℃ full range (3-wire platinum resistance thermometer) - Compatible with ITS90, EN60751 (DIN90), CVD temperature coefficients - Measurement range: -200 to 850℃ - Resolution: 0.001℃ - Stability: Below 0.005℃/year - Temperature units: ℃, F, K, Ω - Standard RS232C interface - Compatible with 4-wire and 3-wire platinum resistance thermometers For other specifications, please refer to the data sheet. Pharmaceutical industry General industry Laboratories, calibration rooms Temperature sensor manufacturing companies Calibration service companies Used for various applications, etc.
The Drywell-type Temperature Calibrator CTD4000 is designed to withstand not only the production environments of factories but also the harsh conditions found in maritime and shipping applications. With a lightweight, compact design that emphasizes simple operability, it boasts exceptional functionality in settings where temperature calibration is essential for process control and quality assurance of finished products. The main body is made of aluminum, and the internal components use both aluminum and stainless steel to achieve lightweight, compact, and robust construction. All temperature calibration baths delivered to customers undergo testing in our calibration lab, where calibration is performed according to procedures compliant with international standards. During this process, all functions are compared against reference parameters and calibration protocols, and a calibration certificate is issued. The heating section of the temperature calibration bath consists of a metal block heated by a resistive thermoelectric module. The block features a bore for probe insertion, allowing the probe of the measuring device to be inserted and used. Upon request, we can provide insert blocks and bores tailored to customer specifications. An option is available to comply with the DNV GL classification standards. On-site simple calibration Equipment calibration within the power plant Measurement and control testing facility Final testing of machinery production Onboard and on-site calibration at marine facilities is particularly suitable for these applications.
The CTD9350 series high-precision dry well temperature calibrator can meet all calibration requirements in laboratories, workspaces, or factory sites. By installing an optional built-in measuring device, it can measure the resistance value of temperature resistance thermometers, the electromotive force of thermocouples, and current signals (output signals from 0/4 to 20 mA transmitters), displaying the results in degrees Celsius. Operation is simple and intuitive, using a large touch panel display. The built-in calibration software allows for the creation of customized calibration tasks. It is also possible to automatically generate calibration certificates. For each task, the time to reach the set temperature is calculated, and the remaining time is displayed. This enables accurate estimation of heating and cooling times. As a temperature controller, it uses a heat block developed specifically for this product, capable of handling temperatures up to 700°C. This ensures high control accuracy and excellent temperature uniformity within the block. The control algorithm is optimized for various calibration processes, minimizing axial temperature fluctuations to reduce calibration uncertainty. Especially suitable for on-site calibration, equipment calibration within power plants, measurement and control testing facilities, and final testing of machinery production.
---

---

---
  1. Featured Products
    ASL High-Precision Digital Temperature Calibrator CTR2000ASL High-Precision Digital Temperature Calibrator CTR2000
    overview
    The ASL brand CTR2000 can measure in either 2-channel or 8-channel configurations. The probes can accommodate 4-wire or 3/4-wire types, allowing you to choose according to your needs. The included probes feature enhanced functionality to achieve high operability and low life costs. For example, there is a function to save calibration data in the main unit's memory. By simply connecting the probe to the connector, the specifications are instantly recognized, enabling data storage with the highest measurement accuracy. Additionally, it is possible to monitor the conditions of the surrounding environment during calibration. <Basic Specifications> - Accuracy: ±0.01℃ full range (4-wire platinum resistance thermometer) ±0.05℃ full range (3-wire platinum resistance thermometer) - Compatible with ITS90, EN60751 (DIN90), CVD temperature coefficients - Measurement range: -200 to 850℃ - Resolution: 0.001℃ - Stability: Below 0.005℃/year - Temperature units: ℃, F, K, Ω - Standard RS232C interface - Compatible with 4-wire and 3-wire platinum resistance thermometers For other specifications, please refer to the data sheet.
    Application/Performance example
    Pharmaceutical industry General industry Laboratories, calibration rooms Temperature sensor manufacturing companies Calibration service companies Used for various applications, etc.
    Compact and lightweight dry well temperature calibrator CTD4000-375Compact and lightweight dry well temperature calibrator CTD4000-375
    overview
    The Drywell-type Temperature Calibrator CTD4000 is designed to withstand not only the production environments of factories but also the harsh conditions found in maritime and shipping applications. With a lightweight, compact design that emphasizes simple operability, it boasts exceptional functionality in settings where temperature calibration is essential for process control and quality assurance of finished products. The main body is made of aluminum, and the internal components use both aluminum and stainless steel to achieve lightweight, compact, and robust construction. All temperature calibration baths delivered to customers undergo testing in our calibration lab, where calibration is performed according to procedures compliant with international standards. During this process, all functions are compared against reference parameters and calibration protocols, and a calibration certificate is issued. The heating section of the temperature calibration bath consists of a metal block heated by a resistive thermoelectric module. The block features a bore for probe insertion, allowing the probe of the measuring device to be inserted and used. Upon request, we can provide insert blocks and bores tailored to customer specifications. An option is available to comply with the DNV GL classification standards.
    Application/Performance example
    On-site simple calibration Equipment calibration within the power plant Measurement and control testing facility Final testing of machinery production Onboard and on-site calibration at marine facilities is particularly suitable for these applications.
    High-Temperature Compatible 700℃ Dry Well Calibrator CTD9350-700High-Temperature Compatible 700℃ Dry Well Calibrator CTD9350-700
    overview
    The CTD9350 series high-precision dry well temperature calibrator can meet all calibration requirements in laboratories, workspaces, or factory sites. By installing an optional built-in measuring device, it can measure the resistance value of temperature resistance thermometers, the electromotive force of thermocouples, and current signals (output signals from 0/4 to 20 mA transmitters), displaying the results in degrees Celsius. Operation is simple and intuitive, using a large touch panel display. The built-in calibration software allows for the creation of customized calibration tasks. It is also possible to automatically generate calibration certificates. For each task, the time to reach the set temperature is calculated, and the remaining time is displayed. This enables accurate estimation of heating and cooling times. As a temperature controller, it uses a heat block developed specifically for this product, capable of handling temperatures up to 700°C. This ensures high control accuracy and excellent temperature uniformity within the block. The control algorithm is optimized for various calibration processes, minimizing axial temperature fluctuations to reduce calibration uncertainty.
    Application/Performance example
    Especially suitable for on-site calibration, equipment calibration within power plants, measurement and control testing facilities, and final testing of machinery production.