1~5 item / All 5 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~5 item / All 5 items
"Hydro Turn" is an oil-water separation filter element/filter unit that utilizes hydrophilic and oleophobic properties for effective oil-water separation. It can achieve a flow rate of 3 liters per minute per filter element, with an oil removal rate of over 98%! When 200 liters of oil-water mixture is fed into the filter unit, separation is completed in about 30 minutes. Two filter elements are used. Additionally, by using a drain separator unit for oil-water separation, the treated water can be discharged, resulting in approximately 1.7 liters of waste treatment liquid per year, equivalent to about 0.01 drums. 【Features】 ■ Enables oil-water separation utilizing hydrophilic and oleophobic properties ■ Achieves a flow rate of 3 liters per minute per filter element, with an oil removal rate of over 98% ■ No unit power or drive required ■ Significant reduction in waste treatment costs *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Induction Countermeasure High Voltage Bridge Type Cable Fault Location Measurement Device" is a measuring instrument that excels in fault location accuracy and usability, employing the well-established Mare Loop method. It can accurately locate resistive ground faults of approximately tens of MΩ that occur in cable lines. Thanks to its unique various induction countermeasure technologies, it can be applied even under induced voltage superimposition of around 200V. 【Features】 ■ High-precision fault location is possible using the Mare Loop method ■ Automatic measurement can be easily performed with CPU control ■ Can be applied even under induced voltage superimposition of around 200V due to unique various induction countermeasure technologies ■ Allows measurement of high-resistance ground faults of approximately tens of MΩ by using a high-voltage power supply (L610) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "LISSA-100" is a device that measures the sheath insulation resistance of 3.3kV and 6.6kV high-voltage cable lines and can detect shield disconnections while the system is live. By combining sheath insulation resistance measurement and shield disconnection detection, it is possible to detect most deteriorated cables. By diagnosing with this measuring instrument, it allows for the selection of cables that need to be diagnosed for shutdown, thereby reducing downtime and streamlining inspection tasks. 【Features】 ■ Both sheath insulation resistance and shielding layer resistance can be measured while the system is live. ■ Measurement data can be stored in internal memory, and data management can be done by connecting to a PC. ■ Measurement can be performed without the need for an AC100V power supply (battery-operated). ■ Resistance measurement can be performed even in the presence of induced voltage. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "LILIA-150T" is a live-line sheath insulation defect measurement device that can identify insulation defects in the sheath regardless of whether the line is live or stopped, contributing to stable power supply. The output of the test power supply is limited to 50V under no load and 1mA during a short circuit, allowing for measurements without damaging the sheath. Additionally, the power supply unit, measurement unit, and AC grounding unit are integrated into a compact, portable structure. 【Features】 - Can identify insulation defects in the sheath regardless of whether the line is live or stopped, contributing to stable power supply. - Accurately measures defects with insulation resistance of less than 1MΩ in the sheath. - Integrated power supply unit, measurement unit, and AC grounding unit, featuring a compact portable structure. - The output of the test power supply is limited to 50V under no load and 1mA during a short circuit. - Allows for measurements without damaging the sheath. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe offer the all-in-one partial discharge measurement device 'B010', which includes all the necessary equipment for partial discharge measurement, such as a corona-free test power supply, calibration pulse generator, blocking coil, and coupling capacitors. Since the test voltage can be adjusted over any desired time, it allows for testing in accordance with various standards, making it suitable for evaluating the insulation performance of electrical components such as power modules, insulation substrates, EV motors, and capacitors. Please feel free to contact us if you have any inquiries. 【Features】 ■ Partial discharge measurement can be performed with this single device ■ Automatic partial discharge measurement using a PC with dedicated software ■ Compact and lightweight portable structure *For more details, please download the PDF or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration