1~10 item / All 10 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~10 item / All 10 items
The cooling and humidifying device "Cool Mist Line" allows workers to feel a temperature of 26-27°C in an environment of 40°C, keeping workers, the workspace, and products dry while providing cooling. It uses 99% air-based mist, mixing 7cc of water per minute for evaporative cooling (rust-free!). Each unit can cool an area from one tatami mat to 2 square meters, with a water usage of about 4 liters per day (for cooling). The air consumption is 28 liters per minute, so we recommend considering the capacity of the compressor (approximately 14 units can be used with a 5-horsepower compressor). During dry periods, it can be used for humidification and static electricity prevention by adjusting the water and air flow from the top of the unit. The maximum humidification water amount is 2.4 liters per hour per unit. It is also used for explosion-proof and dust prevention purposes.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Cool Mist Fan Mini" is a compact mist blower suitable for cooling the driver's seat of forklifts, tractors, and construction machinery. By utilizing the evaporative cooling effect of compressed air and a small amount of water, it can cool the surrounding area without getting it wet, contributing to improved working conditions and prevention of heat-related illnesses. The power consumption is low, at a maximum of about 18W, allowing it to be powered by the vehicle's battery or a commercially available 12V portable battery. 【Features】 - Compact and space-saving, easy to install - Three-stage adjustment function - Utility model and trademark registration pending *You can view the product documentation by downloading the PDF. Please feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Cool Mist Line" is an original cooling device that cools the workspace using the evaporative heat from compressed air and a small amount of water. Unlike mist showers, it is suitable for those who are uncomfortable with air conditioning, as there is no worry of getting workers or items wet. It achieves -8°C using only air and water! Please consider introducing it in preparation for this year's extreme heat. 【Features】 ◆ Effective not only for cooling and humidifying but also for preventing static electricity and viruses ◆ Electricity costs are incurred only for the compressor in use ◆ Ready to operate immediately with a connection to the compressor and water supply *Please download the PDF to view the case studies. Demo units are also available for loan.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Cool Mist Line" is a device that cools the workspace using the evaporative cooling effect of compressed air and a small amount of water. It is installed above the workers' area and sprays ultra-fine mist particles (15 microns). Even though it is mist, there is no worry about getting wet, and it can cool an area roughly the size of a tatami mat. Both air and water incur minimal costs, contributing to a reduction in air conditioning expenses. 【Features】 ■ Significantly reduces electricity costs in summer ■ Low installation and setup costs ■ Easy maintenance ■ Demo units available for loan *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration1: Explosion prevention measures at a gravure printing factory. 2: Static electricity prevention measures at a printing factory. 3: Static electricity prevention measures at a film factory. 4: Static electricity prevention measures at a plastic processing factory. 5: Explosion prevention measures at an automobile dismantling factory. 6: Static electricity prevention measures in the linen industry. 7: Space disinfection and humidification measures in nursing facilities and hospitals. 8: Humidification measures in house cultivation. ○ The "Cool Mist Line," which can be used for cooling, humidification, and static electricity prevention in various applications, is a mist that mixes air from a compressor with water and sprays it (evaporative cooling method). ○ It has received positive feedback for its non-wetting mist, allowing for pinpoint cooling and humidification. ○ The water volume can be increased using the water volume adjustment dial on the mist unit, releasing 2.4L of water per hour without wetting. ○ There is no need for water replenishment. It significantly reduces electricity costs compared to humidifiers. ○ It can be used for various applications, including space disinfection as a virus countermeasure, regardless of the industry. ○ Being air-operated, it has less clogging from substances like scale, and regular maintenance is not required. Usage instructions: The compressor requires 28L of air per minute. : Water is needed (direct connection to water supply or tank for water supply). : Spray with the nozzle facing upwards at an air pressure of 0.2Mpa.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to the cooling effect of our energy-saving cooling device, "Cool Mist Line." When Cool Mist Line was sprayed on a person's back for 30 seconds, the surface temperature decreased from 30.6°C before the start to 18.3°C after 20 seconds, demonstrating its cooling effect. Furthermore, it is possible to reduce electricity consumption by approximately 85% compared to the usage of a <spot air conditioner (two-port type)>. 【Features】 ■ Approximately 85% reduction in electricity consumption compared to spot air conditioners ■ Reduction in electricity costs ■ Cooling effect ■ Energy saving *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces case studies of the "Cool Mist Line" handled by Toyoko Support Co., Ltd. implemented in various companies. Each company faces different challenges, including those that used portable spot coolers and those that did not implement heat measures in factories with high ceilings where temperatures exceed 40°C. The content is based on customer feedback. [Featured Case Studies] ■ Recycling Intermediate Processing Plant ■ Concrete Plant ■ Automobile Repair Shop ■ Linen Factory ■ Printing and Binding Factory ■ Cleaning Factory *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis product is a gate-type mist sprayer that can disinfect (sterilize) the entire body in 3 seconds. It is capable of blowing away dust, ducts, and pollen with air blow. It is suitable for use in kindergartens, schools, nursing homes, and various factories. 【Features】 ■ Disinfects the entire body in 3 seconds ■ Sterilization is also possible ■ Can blow away dust, ducts, and pollen ■ Effective in crowded places ■ Gate-type *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Cool Mist Fan Fuujin" is a powerful cooling device capable of cooling over a distance of 10 meters. At 60Hz, it can deliver a wind speed of 1m to a distance of 16m with a power consumption of 35W. Equipped with three Cool Mist Line nozzles, it allows for powerful and extensive cooling. Water usage ranges from 1.26L to 7.2L/min per unit. Air usage starts from 90L/min per Fuujin unit. 【Features】 ■ Powerful cooling ■ Extensive cooling ■ Water usage: from 1.26L to 7.2L/min per unit ■ Air usage: from 90L/min per unit ■ Low noise design at 52dB *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Cool Mist Line" is an ultra-fine particle water generation device suitable for cooling in factories such as parts manufacturing, food processing, cleaning, glass crafts, and linen production. The product manual provides clear explanations with photos on handling instructions, maintenance methods, installation images, installation locations, and adjustment methods. The manual includes points of caution, pre-use instructions, air supply, and methods for water supply and adjustment. 【Contents Included】 ■ Cool Mist Line Manual ■ Maintenance Methods ■ Installation Images ■ Installation Locations and Adjustment Methods *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration