136~180 item / All 203 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration136~180 item / All 203 items
● High-precision temperature and humidity measurement ● Available in wall-mounted and duct-insert types ● Temperature and humidity elements are replaceable ● Replacement elements are calibrated for both temperature and humidity ● Capable of calculating dew point temperature, absolute humidity, and mixing ratio ■ The EE212 allows for the exchange of humidity (RH) and temperature (T) sensor modules, making it optimized for HVAC control applications across various industries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe accept calibration for products that are not sold within the Tekune measurement range, as long as they fall within our supply scope. However, please note that there are some products for which adjustments cannot be made by our company. For inquiries regarding the possibility of adjustments for other companies' products, please contact us through the inquiry form. For details on calibration by other companies and general calibration information, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company maintains traceability equipment within the following range and ensures traceability at all times. *Traceability: The property of measurement results or standard values that can be linked to specified standards through an unbroken chain of comparisons where all uncertainties are documented. The standards are usually national standards or international standards.* (1) Dew Point Reference instrument maintenance range: -90 to +70°C 1. -70 to +10°C: Calibration cycle 1 year, applicable evaluation standard AIST 2. -80 to +10°C: Calibration cycle 2 years, applicable evaluation standard NIST 3. -10 to +70°C: Calibration cycle 2 years, applicable evaluation standard AIST 4. Humidity 20 to 80%: Calibration cycle 2 years, applicable evaluation standard AIST (2) Temperature* Reference instrument maintenance range: 0 to +100°C (3) Oxygen* Reference instrument maintenance range: 100 ppm, 1% (4) CO2* Reference instrument maintenance range: 1000 ppm (5) SF6* Reference instrument maintenance range: 95%, 98% *For details regarding the calibration supply range and general calibration of items from (2) Temperature onward, please refer to the following URL.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe are registered as the first JCSS calibration provider in Japan for low dew point ranges from -10°C to -70°C. As a result, in addition to conventional ISO 9001 calibration with traceability, we are able to perform calibrations in accordance with the equipment, quality system, and calibration methods that have been certified as appropriate by JCSS in compliance with ISO/IEC 17025, and the uncertainty of these calibrations is recognized by the government. The results are issued as calibration certificates bearing the JCSS logo. Additionally, our company is certified as an international MRA-compliant provider, and the calibration certificates issued by us with the JCSS logo are accepted internationally through the Mutual Recognition Arrangement (MRA). For more details on JCSS, MRA, and international standards, please visit the following URL.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe are implementing a quality management system aimed at providing consistent products and services and improving customer satisfaction. In calibration as well, we issue traceability-related documents in accordance with a strict system based on the same standards. For more information related to ISO 9001 and general calibration details, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTo maintain reliable measurements, we recommend regular calibration of each measuring instrument. Measuring instruments are subject to aging, and any instrument is likely to experience increased measurement errors over time. It is important to ensure that these errors do not affect measurement accuracy. The calibration cycle varies depending on the instrument. For the TK-100 dew point meter, we recommend calibration once a year due to the aging of the ceramic in the measurement section. However, for hygrometers that use artificial, highly stable polymers and PT100 temperature sensors, we recommend calibration every two years for the main mirror-cooled (mirror-type) dew point meters. For more details on calibration, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe have adopted a unique automatic calibration method (double beam NDIR method). As a result, it excels in long-term stability and maintainability, and the annual drift is kept very low at 20 ppm/year. Its reliability is proven not only through rigorous testing but also by its market share in Europe. Please choose from the duct-mounted EE850, wall-mounted EE800, or agricultural EE820. You can also select concentration scaling and output options. For more details on CO2 meters in general, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWhen measuring the dew point and oxygen concentration in the atmosphere gas inside the furnace, the gas is sampled with a pump, impurities are removed with a filter, and then measurements are taken.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationUncertainty is like the sum of factors contributing to error, so naturally, the fewer the factors of error, the smaller the uncertainty will be. In other words, when repeating a "calibration chain" to "ensure traceability," the more calibration instances there are, the greater the uncertainty becomes, and the lower the reliability. This is because environmental factors, the inherent errors of the instruments, and errors introduced by the measurer accumulate with each calibration. Generally, it is said that adding one more calibration doubles the uncertainty. Therefore, even when calibrating to ensure traceability, it is better to perform the calibration with instruments that are as close as possible to national standards. At Tekune Measurement, we possess and sell instruments that are close to national standards. For more details on uncertainty and traceability, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn Tekune Measurement, we handle two types of oxygen concentration meters based on the principles of galvanic cell and zirconia methods. 〇 Galvanic Cell Type The lead anode performs an oxidation reaction, assisting the reduction reaction at the cathode. It behaves as if combustion is occurring at the anode due to oxygen, generating current, which is why it is also called a fuel cell type. PPM models: 2010BX, 2001RS, 2001LC, 1000RS % models: 210BX, Oxtron, 201RS, 1100BE, 201LC 〇 Zirconia Type It compares an unknown process gas with a known reference gas using the Nernst equation. The sensor measures the electromotive force to determine the oxygen concentration. Examples of PPM models: 4100, 7100, etc. Examples of % models: 111, 5100, etc. For more details on the principles of oxygen concentration measurement, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe adopt TDLAS. TDLAS stands for Tunable Diode Laser Absorption Spectroscopy, which is also known as wavelength-tunable semiconductor laser absorption spectroscopy. Laser light generated by a semiconductor laser is irradiated into a measurement cell, and the intensity of the laser light that has passed through the measurement cell is measured. This TDLAS allows for a rapid response to changes in moisture concentration and enables accurate monitoring of saturated vapor amounts. Additionally, the use of dew point meters, which can measure moisture concentration quickly and accurately, is increasing in determining the purchase price of natural gas in Europe and the United States. The measurement range can detect low dew points down to -60 °C dp. For more details on the principles of laser dew point meters, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe principle of pentoxide phosphoric acid (electrolytic) moisture analysis is utilized. (1) Phosphoric acid generates phosphorus pentoxide, hydrogen, and oxygen through electrolysis. 4H3PO4 → 2P2O5 + 6H2 + 3O2 (2) Phosphorus pentoxide absorbs water. 2P2O5 → 6H2O + 4H3PO4 The sensor is made of glass, with platinum electrodes (rhodium as an option) wound in a spiral around it. Oxygen is generated between the electrodes. The amount of water absorbed by the generated phosphorus pentoxide balances with the amount of hydrogen and oxygen produced, allowing for moisture measurement based on Faraday's law (the amount of substance electrolyzed is proportional to the amount of electric charge passed). It is resistant to corrosion, making it suitable for measuring moisture in corrosive gas environments. Additionally, it is a long-established dew point meter. For more details on the principle of the phosphorus pentoxide dew point meter, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Compact modular-type analyzer, small and easy to integrate into equipment ● Monitor interface: RS232, current output, voltage output, range identification voltage output ● Alarm output (upper limit, lower limit, system fault) ● High response speed: under 15 seconds (90%) ● Measurement range: 0 to 100% ■ Model 5100 is a cost-effective zirconia oxygen analyzer that can measure oxygen concentration at percent levels in environments free of corrosive and flammable gases. ■ The "Limit Current Type Zirconia Sensor ZR500" is built into the main unit and connects to the sample line. Additionally, an external sensor model is also available as an option.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● High-speed response within 10 seconds from air to ppm level ● Measurement range from ppm level to 100% ● Compact modular-type analyzer, easy to integrate into equipment ● Monitor interface: RS232, current output, voltage output, range selection voltage output ● Alarm output (upper limit, lower limit, system fault) ● Remote sensor unit ● Long-life zirconia oxide sensor ■ This is a compact oxygen analyzer featuring a fast response zirconia oxygen sensor and a measurement range from 0.1 ppm to 100%. It is suitable for measuring various gases and for critical process control applications. ■ The robust design of the sensor allows for rapid response to significant changes in oxygen concentration, enabling accurate measurement of ppm concentration within seconds after exposure to air. ■ Equipped with digital output, analog output, and alarm contacts, it can meet various user requirements. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement range: 0 to 1000 ppm ● Enhanced monitoring interface (RS232, current, voltage, range voltage) ● Remote sensor model ● Alarm output (upper limit, lower limit, system fault) ● Long-life zirconia oxide sensor ■ Model 7100 is an oxygen analyzer capable of measuring in the range of 0 to 1000 ppm. It is a compact oxygen analyzer that uses a long-life zirconia oxide sensor. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Long-life zirconia sensor ● Measurement of percent levels ● Arbitrary setting of output range ● Simple operation from the front panel ■ Model 70 is a zirconia oxygen analyzer capable of measuring from 0.1% to 25%. An optional model that can measure up to 95% is also available. ■ All necessary user operations, such as span changes during calibration and changes to the output range, can be performed from the front panel. Furthermore, the unit requires no maintenance. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement of percent level ● New book size 2.5kg ● Standard equipped with sampling system ● Pump - intrinsically safe explosion-proof type available ● Data logging function (up to 20,000 points) ● Various settings available via PC connection ■ Model 111 is a compact oxygen analyzer that adopts a zirconia type for measuring percent levels. To simplify flow adjustment, a needle valve and flow meter are standard equipped, allowing for easy connection to the sample gas and quick measurement initiation. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● An environment free of corrosive and flammable gases ● Wide measurement range of 75 ppb to 100% ● Long-life zirconia oxide sensor ● Measures up to 1000 ppm from the atmosphere in under 30 seconds ● Built-in flow meter and needle valve ● Comprehensive interface (current output, voltage output, range voltage output, RS232C output) ■ The MODEL OA-1S+ is a portable oxygen analyzer capable of measuring a wide range from 75 ppb to 100%. It features a high-response, long-life zirconia sensor ZR-100 built into the main unit. It measures up to 1000 ppm from the atmosphere in under 30 seconds. Users can connect their sampling pipe to the back of the unit to measure oxygen concentration. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement range: 0.1 ppm to 100% ● In an environment without corrosive or flammable gases ● Operating flow rate: 0.5 to 3.0 L/min ● Measures up to 1000 ppm from the atmosphere with a 95% response in under 5 seconds ● Built-in flow meter and needle valve ● Comprehensive interface (current output, voltage output, range voltage output, RS232C output) ■ The Model OA-1 is a portable oxygen analyzer capable of measuring a wide range from 0.1 ppm to 100%. It features a high-response, long-life zirconia sensor (ZR-100) built into the main unit. It measures up to 1000 ppm from the atmosphere with a 95% response in under 5 seconds. Users can connect their sampling pipe to the back of the unit to measure oxygen concentration. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement at ppb level from the atmosphere in less than 15 minutes ● Long-life zirconia oxygen sensor ● Monitor interface: RS232, current output, voltage output, range selection voltage output ● Alarm output (upper limit, lower limit, system fault) ● Remote sensor unit ● Large, bright LED, easy operation ■ This is a compact oxygen analyzer for trace oxygen concentration measurement and process control applications. With very high accuracy, fast response, and long-term stability, it provides stable measurements with minimal maintenance for critical applications requiring ppb level oxygen contamination monitoring. ■ In addition to a measurement range from 50 ppb to 100%, it comes with a remote sensor module equipped with a high-response zirconia sensor from Neutronics. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Proper management of N2 purge amounts for various process equipment ● Improved safety through explosion limit management ● Domestic explosion-proof certification obtained ■ This oxygen concentration meter is designed with double safety in mind, equipped with two sensors to handle unexpected situations. ■ It features a feedback control function for the flow rate of inert gas introduced into the process vessel. ■ This oxygen analyzer adopts a unique pinhole-type galvanic sensor that is resistant to high temperatures, high pressures, and impurities, and has a fast response time. ■ By controlling the appropriate flow rate of inert gas, it can reduce VOCs that are discharged simultaneously with the inert gas. ■ The calibration of the oxygen sensor is fully automatic, and it can output predictions for sensor replacement timing and replacement timing alarms. ■ It includes three contacts for remote status indication, four factory-set contacts, and five user-set contacts. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Oxygen deficiency management percent (%) model ● Equipped with a backup battery power supply ● Adopts long-life zirconia-type sensor ● Simple operation from the front panel ● Complies with UL safety standards in the United States ● Oxygen analyzer ■ Model 221R is designed to be installed and used in areas at risk of oxygen deficiency. It uses a 100VAC power supply and is also equipped with a backup battery power supply, allowing for continuous oxygen concentration management even in the event of a power issue. The accuracy is ±0.1%, the output range is 0-25%, alarms can be set at two points, and the 90% response time is 15 seconds.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBy cooling the sample gas, we measure the changes in the way light is reflected and scattered by a small mirror inside the measuring instrument, where dew or frost forms at the start of condensation. Since it is a measuring instrument that directly adopts the principle of dew point, it is used as a standard device. The measurement range is from -100 °C dp to +100 °C dp. The measurement accuracy is ±2 °C dp. For more details on the principle of mirror-cooled (mirror-type) dew point meters, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe sensor uses a polymer material. The principle is the same as that of aluminum oxide sensors. The polymer-based capacitive sensor is a capacitor that has a dielectric layer that reacts to moisture in the surrounding gas. This dielectric layer ideally absorbs moisture in the same proportion as the surrounding moisture content, allowing it to detect moisture levels. Its advantages include fast response speed and long-term stability. However, measurements in low dew point areas below -50 °C dp have lower sensitivity compared to aluminum oxide types, so it outputs calculated values that merge actual measurements with predictions. Therefore, without an automatic calibration function, it cannot maintain accuracy. It has an automatic calibration function that corrects the zero point through heating, maintaining accuracy. The measurement range is from -60 °C dp to +100 °C dp. For more details on the principle of the polymer capacitive dew point meter, please refer to the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurable in 2 minutes of warm-up ● Built-in pump ● Compact (body) W232×H150×D172 mm, 2.7 kg ● Long-life zirconia oxide sensor ● Almost no maintenance required (no worries about drying or freezing) ● Alarm (upper and lower limits) ● RS-232 serial interface ■ The Model 7100P is a portable oxygen analyzer capable of measuring a range of 0 to 1000 ppm. The measurement ranges are 0–100 ppm and 0–1000 ppm, with options for auto range or fixed range switching. Measurements can be taken after a 2-minute warm-up. ■ In addition to using a long-life zirconia oxide sensor, it requires almost no maintenance, and there are no concerns about drying or freezing. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration1) Easy to handle Unlike the Karl Fischer method, no special techniques or reagents are required. With the handheld type, you can measure simply by inserting the probe into the oil. (It responds in 5 to 10 minutes.) With the continuous measurement type, by installing the probe in the oil flow path, you can continuously monitor moisture changes, which can be used for diagnosing oil contamination and degradation, ensuring you don't miss the timing for oil replacement. 2) Quantitative evaluation of various oils is possible When displaying in ppm conversion, we conduct analysis using the Karl Fischer method and set a conversion coefficient suitable for that oil. Therefore, even with ppm measurements, you can measure various oils while maintaining measurement accuracy equivalent to the Karl Fischer method. 3) Easy maintenance Customers can clean the sensor part themselves. We also provide a simple calibration kit, allowing customers to perform simple calibrations on their own. Repairs and calibrations, such as probe and sensor replacements, can also be conducted domestically. Our technicians can visit the site to perform calibrations on-site as well. For more details on moisture measurement in oil, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe believe that our products are essential for quality management, supporting activities such as managing customer work environment standards and product performance evaluations. At Techne Measurement, we recognize our obligation to provide our customers with the best products and have established a quality management system based on ISO 9001. ISO 9001 is an international standard for management systems aimed at providing consistent products and services to enhance customer satisfaction. Additionally, we are the first in Japan to be registered as a JCSS calibration provider in the low dew point range from -10°C to -70°C. JCSS is a system where NITE (National Institute of Technology and Evaluation), on behalf of the Minister of Economy, Trade and Industry, registers calibration organizations based on the Measurement Law, established to ensure the reliability of high-precision measurement and quality management. Only organizations recognized through examinations based on the Measurement Law (skill tests and document/field audits) that meet the criteria for calibration capability, quality systems, and uncertainty estimation methods can be registered as JCSS calibration providers. For more details on quality management, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement range: 0.1ppm to 100% ● Built-in pump ● For environments without corrosive or flammable gases ● Comprehensive interface (current output, voltage output, range voltage output, RS232C output) ● Long-life zirconia oxide sensor ● Measures from atmospheric levels to 1000ppm with a 95% response in under 5 seconds ■ The MODELPURE N2 is a portable oxygen analyzer with a built-in pump capable of measuring a wide range from 0.1ppm to 100%. ■ It features an integrated design with the sensor built into the main unit, suitable for measuring oxygen concentration in environments without corrosive or flammable gases and under pressure-free conditions, from research and development to industrial measurement. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe are selling the next-generation VTQ new sensor anemometer proudly developed by E+E. (VTQ Sensor: A groundbreaking sensor that allows for long-term measurements even in the presence of dust, minimizing errors, based on the same principle as thermal anemometers.) A common issue in wind speed measurement is that dust and dirt adhering to the sensor during measurement can significantly increase measurement errors, eventually leading to failure. However, the VTQ has researched the airflow around the sensor and has greatly reduced dust adhesion by preventing dust from directly contacting the sensor. This has enabled continuous and stable measurements. For more details about the anemometer, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Techne Measurement Co., Ltd., we translate, publish, and sell the "Guidelines for Humidity Measurement." This document was jointly produced with the support of the National Measurement System Policy Department of the UK Department for Business, Energy & Industrial Strategy, the National Physical Laboratory (NPL), and the Institute of Measurement and Control. If you would like to order this document, please do so through the contact form below. For more details about the "Guidelines for Humidity Measurement," please visit the following URL.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement range: -60 to +60 ℃dp ● Maximum pressure: 10 MPa ● Accuracy: ±2 ℃dp ● Automatic calibration function The core dew point detection component of the EE371 dew point transmitter utilizes the monolithic cell type temperature and humidity sensor HMC2000, which employs E+E's thin-film technology. The built-in automatic calibration system enables an accuracy within ±2℃. Its compact and robust metal housing, 360° rotating mounting screw, and various connection screw diameters facilitate easy installation and maintenance. For more details, please contact us or refer to the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Dedicated model for glove boxes ● Galvanic type resistant to combustible gases and organic solvents ● Choose from PPM model or % model ● Minimal leakage due to ALLSUS piping inside the device ● Excellent operability and maintainability ■ This unit can measure oxygen concentration at ppm or % levels according to the application. It has a built-in flow meter, needle valve, and pump, allowing for easy measurement of ppm level oxygen concentration by simply connecting to the sample IN/OUT. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● In addition to measuring dew point (Td), it is also capable of measuring frost point (Tf) and volumetric concentration (Wv). ● Compact design. ● Stainless steel housing structure. ● Measurement values are output in analog 4-20 mA and digital Modbus RTU. ■ The EE354 is a transmitter capable of measuring dew points down to -20 °C dp. Its compact design and robust stainless steel housing structure make it easy to install and use in various applications. ■ By using an optional USB-RS485 converter and free downloadable configuration software, you can change settings such as analog output. Additionally, single-point and two-point calibration can also be performed via the software.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Digital sensor platform ● Used in combination with various sensor probes from E+E ● Up to 3 probes can be connected ● Maximum display of 3 points and output of 2 points possible ● Connectable via USB-C, settings can be changed ■ The Sigma 05 sensor hub is a foundational device equipped with outputs and a display, used in combination with E+E sensor probes. The Sigma 05 automatically detects E+E probes and performs hub setup based on the configuration.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Easy installation with all-in-one design ■ Simple operability ■ Choose a dew point meter based on application TK: Low dew point TK-100 built-in dew point meter TE: Medium dew point TE-660 built-in dew point meter ■ For measuring furnace atmosphere ■ For measuring chamber atmosphere This product is an all-in-one wall-mounted dew point meter equipped with a dew point meter and necessary sampling equipment. It includes a filter, needle valve, flow meter, and pump. The dew point meter features the well-regarded capacitive dew point meter TK-100 or the polymer dew point meter TE-660 from Techne Measurement Co., Ltd. for furnace dew point management. For applications with a lot of dust, an external pre-filter (optional-PF) is recommended. For more details, please download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Ideal for spot checks ■ Simple operability ■ Choose from PPM model or % model ■ For measuring atmosphere in furnaces ■ For measuring atmosphere in tanks This product is an all-in-one portable oxygen meter equipped with necessary sampling equipment for oxygen measurement. It includes a filter, pump, needle valve (built into the oxygen meter), flow meter (built into the oxygen meter), a ball valve for sealing the oxygen sensor, and a bypass line. This allows for complete oxygen measurement in general environments. Additionally, for applications with a lot of dust, an external pre-filter is available as an option. The oxygen concentration meter is equipped with the AMI galvanic battery-operated oxygen meters 2001LC (for ppm measurement) or 201LC (for % measurement), which are well-regarded for measuring oxygen in furnaces. For more details, please download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration★It can be installed as is and used immediately! This is an all-in-one type of installed dew point meter. It comes with a built-in filter, needle valve, and flow meter. The dew point meter is equipped with either the capacitive dew point meter TK-100 or the polymer dew point meter TE-660, both of which are well-regarded for measuring dew points in furnaces, manufactured by Techne Measurement. For more details, please download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Outputs oxygen concentration of 0-25% at 0-2.5 V ● In a non-corrosive and non-combustible environment ● Adopts long-life zirconia sensor ● Accuracy ±1% full scale ● Oxygen analyzer ■ Model 65 is a compact zirconia oxygen probe capable of measuring from 0.1% to 25%. An optional model that can measure up to 90% is also available. ■ Model 65 uses a zirconia sensor, ensuring a long lifespan and is ideal for measuring oxygen concentration in non-corrosive and non-combustible gases. If you provide a DC power supply of 10 to 28 V, it will output the oxygen concentration range of 0 to 25% at 0 to 2.5 V. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Ideal for spot checks ■ Simple operability ■ Choose a dew point meter according to the application TK: Built-in TK-100 dew point meter for low dew points TE: Built-in TE-660 dew point meter for medium dew points ■ For measuring furnace atmosphere ■ For measuring chamber atmosphere This product is a portable all-in-one dew point meter equipped with a dew point meter and the necessary sampling equipment for measurement. It includes a filter, needle valve, flow meter, and pump. The dew point meter features the well-regarded capacitive dew point meter TK-100 or the polymer dew point meter TE-660 manufactured by Techne Measurement Co., Ltd. for furnace dew point management. For applications with a lot of dust, an external pre-filter (optional-PF) is recommended. For more details, please download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCO2 meters are used in various familiar places. 〇 Plant factories We offer CO2 meters (CO2 concentration meters) for plant factories and greenhouses. Although the environment can be harsh for CO2 meters (due to pesticides and high humidity), the stability of the sensors and protective technologies enable stable CO2 concentration measurements. Managing CO2 concentration within the factory is one of the most important management items for growth and its significance is increasing. Examples: EE800, EE820, HUMLOG 〇 Building air conditioning In recent years, there has been a call for improvements in the working environment, and it has become well-known that the environment also affects actual work efficiency. It is necessary to measure CO2 concentration with CO2 meters (CO2 concentration meters) to achieve a balance between air quality, energy conservation, and ventilation efficiency; however, inaccurate measurements will not yield sufficient control effects. Therefore, the CO2 meters (CO2 concentration meters) from Tekhne Measurement, which adopt a new method, are being adopted for their long-term stability and maintainability. Examples: EE800, EE850, HUMLOG20, TEKHNEPort, EE894, CO2 Guard
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration★It can be installed as is and used immediately! ■ Polymer-based oil moisture meter ■ Moisture activity value measurement range 0-1 aw ■ Measurement in ppm is possible ■ Option to choose whether or not to include a TFT display* *There are also selection options such as a patrol light, so please refer to the basic information. The core moisture detection component of the EE360 oil moisture meter equipped in TKZH002 utilizes a polymer sensor that employs thin-film technology. *Only for the EE33 temperature and humidity dew point transmitter designed for high humidity and harsh environments. It is a moisture meter with low aging changes, high performance, and fast response. Since it provides continuous online measurement, it will notify you via an alarm to address moisture and the timing for oil replacement before moisture contaminates the oil and affects insulation properties.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationVarious devices can be connected and used immediately. ■ Can be placed on a desk, easy to carry and move It can also be used for purposes other than a dew point meter. ■ Main applications For the display of the TK-100/TE-660 dew point meter series For the display of the Model 65 oxygen meter, and for the display of other devices For PPM display (optional) For more details, please download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measurement of water activity (aw), oil temperature (°C), and moisture content (ppm) in oil is possible. ● Two 4-20mA analog outputs or Modbus-RTU digital output. ● Maximum pressure of 2MPa. ● Choice of G1/2" ISO thread or 1/2" NPT thread connection. ■ The EE364 is a compact oil moisture meter that allows for the selection of two types of outputs among water activity (aw), moisture content (ppm), and oil temperature (°C). ■ With a compact design and robust stainless steel housing structure, it is easy to install in various applications, minimizing wasted space. Diagnosing oil degradation is crucial for maintaining the long-term performance and maintenance of factories and equipment. For more details, please download the catalog or contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe provide a brief explanation of terms related to dew point meters, oxygen concentration meters, and more. 【Contents】 ■ Thinking about water ■ About measuring instruments ■ Calibration ■ Building a measurement system ■ About standards *For more details, please visit the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe have compiled questions regarding technology, products, and measurements. 【Contents】 ■ Regarding Technology - About moisture ■ Regarding Products - About product selection - About product specifications - About product-related knowledge ■ Regarding Measurements - About measurement feasibility - About equipment - About electrical connections ■ Regarding After-Sales Service - About calibration - About support - Troubleshooting *For more details, please be sure to check the URL below.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration